Page 145

Chapter 7: Setting Parameters Saving Changes To Parameters

7.3.7 Saving Changes To Parameters Whenever a parameter value is altered, the new value must be saved. To do this: •

Press <F4> – the “SAVE” function key.

If a parameter value is changed and the menu exited before the change is saved, a dialog box appears asking whether or not the operator wants to save the changes.

7.3.8 Resetting The Terminal Note: Regardless of the type of terminal you are using, a reset will result in a complete reboot of the unit. When the terminal is reset, it reboots to the Tekterm application and parameter changes take effect.

7.3.8.1 Resetting The 7035 To reset a 7035: •

Press and hold down the <BLUE> key and the <ENTER/ON> key for a minimum of six seconds.

7.3.8.2 Resetting The 8255 And 8260 To reset an 8255 or 8260: •

Using the On/Off switch, turn the terminal off and back on again.

7.3.9 Resetting Parameters To Default Values Important:

• • •

When <F3> – the DEFAULT key – is pressed, all parameter values revert to the factory defaults, including those values that you’ve changed and saved.

Press <F3> – the “DEFAULT” function key – to reinstate the default parameter values. Press <F4> – the “SAVE” function key – to save the changes. Reset the terminal. See "Resetting The Terminal" above.

Teklogix 7035, 8255 & 8260 Terminals User Manual

119

Page 146

Chapter 7: Setting Parameters Terminal Parameters

7.4 Terminal Parameters Warning:

Parameters should not be altered without a clear understanding of how they operate. Parameters that are incorrectly set can increase response time or cause communication difficulties. Generally, parameters are configured for each site during installation.

The “Parameters” menus can only be accessed by individuals with the proper security password. Security is divided into two levels: Supervisory and Psion Teklogix Personnel passwords. Refer to “Security” on page 195 for details about changing the default supervisory level password. Refer to “Allow Teklogix” on page 195 for details about the Psion Teklogix support level password. Important:

Only individuals with a supervisory level or Psion Teklogix support level password can access and change these parameters.

7.4.1 Displaying The Parameters Menu The “Parameters” application is launched from the start up “Display Menu”. If your terminal is currently in the Tekterm application: •

Press <ALT>, and type the letter x.

The “Display Menu” appears on your screen. 01 Display Menu A Parameters B Emulations C DOS Prompt

To display the “Parameters” menu from the startup “Display” menu: •

Type the letter a.

•

Type your supervisory level password in the ‘Password’ window, and press <ENTER>. This is 123456 by default. (Refer to “Security” on page 195 for details on changing the default password.)

120 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 147

Chapter 7: Setting Parameters Displaying The Parameters Menu

Parameters System Scanner Applications View Manager GPS Ports Global Macros Network SNMP Radio Sound ANSI FK Remap Security

» » » » » » » » » » » » »

The Parameters menu is a first level menu that contains parameters for the configuration and customization of a terminal. To access sub-menus attached to these parameters: •

Use the <UP> and <DOWN> arrow keys to position the cursor on the appropriate menu item.

•

Press <F1> – the “NEXT” key – to display the sub-menu.

To display the previous menu: •

Press <F2> – the “PREVIOUS” key, or

•

Press the <ESC> key.

Teklogix 7035, 8255 & 8260 Terminals User Manual

121

Page 148

Chapter 7: Setting Parameters System

7.5 System The parameters listed under the “System” menu allow you to customize terminal attributes such as volume, contrast and font size. System Range Volume 15 0..15 Contrast 0 -5..5 Key Click Y» see text One-Shot Mode » see text Typematic Rpt Y » see text Caps Lock On N Y/N Panning » see text Backlight » see text Font Size 18x20 see text Cursor Type Underline see text Palette Remap » see text Watchdog timer 0 0..30 Power » see text Serial Number see text

7.5.1 Volume And Contrast Both the terminal beeper volume and the screen contrast can be adjusted using the <BLUE> key in combination with function keys <F1> to <F4>. However, these changes are not saved to memory – that is, when the terminal is reset, any volume and contrast adjustments are lost. For information on manual beeper volume adjustments, refer to “Beeper Volume – <BLUE> <F3> And <F4>” on page 34. For details on manual contrast adjustments, refer to “Contrast Adjustment – <BLUE> <F1> And <F2>” on page 36. Adjustments made to the terminal beeper and the display using the “Volume” and “Contrast” parameters are saved to memory so that if the terminal is turned off or reset, the adjustments are saved.

Volume The “Volume” parameter is used to adjust the beeper volume of the terminal beeper. The higher the value entered, the louder the beeper volume of the terminal. The allowable range is 0 to 15. When a volume adjustment is made using this parameter, it is saved to memory.

122 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 149

Chapter 7: Setting Parameters Key Click

Contrast Note: The “Contrast” parameter is not available for 8255 terminals equipped with vacuum fluorescent displays. This parameter is used to adjust the terminal screen contrast. The allowable range is -5 to 5. The higher the value assigned, the darker the screen contrast.

7.5.2 Key Click Key click Tone 2675 Duration 75

Range 200-5000 25-150

The parameters in the Key Click sub-menu are used to adjust the sound emitted from the terminal when a key is pressed. When “Key Click” is set to Y, an audible sound is emitted from the terminal with each key pressed. Setting this parameter to “N” disables the key click sound.

Tone The value entered in the “Tone” parameter determines the frequency of the key clicks and is measured in Hz. The allowable range is 200 to 5000. The higher the value, the higher the pitch.

Duration The value entered in the “Duration” parameter measures the length of time a sound is emitted when a key is pressed and is measured in milliseconds. The allowable range is 25 to 150.

7.5.3 One-Shot Mode One Shot Mode Orange Key N Blue Key Y

Range Y/N Y/N

In “One Shot” mode, a key is only active until the next key is pressed. To lock a key “ON”, it must be pressed twice. When a key is locked on, it remains active until it is pressed a third time to deactivate it.

Teklogix 7035, 8255 & 8260 Terminals User Manual

123

Page 150

Chapter 7: Setting Parameters Typematic Rpt The “One Shot” menu allows you to configure the <BLUE> and <ORANGE> keys to operate in one shot mode or to lock “ON” automatically after being pressed only once.

Orange Key By default, the <ORANGE> key automatically locks” ON” after being pressed once. If you prefer that this key only remain active until the next key is pressed (one shot mode): • Set the “Orange Key” parameter to “Y”. To set this key to lock “ON” automatically after being pressed only once: • Set the “Orange Key” parameter to “N”.

Blue Key The <BLUE> key is set to one shot mode by default – it is only active until the next key is pressed. To set this key to lock “ON” automatically after being pressed only once: • Set the “Blue Key” parameter to “N”. To set the <BLUE> key to one shot mode: • Set the “Blue Key” parameter to “Y”.

7.5.4 Typematic Rpt Typematic rpt Delay 500 ms Rate 5 cps Test

Range see text 1 cps..10 cps see text

When this parameter is enabled (set to “Y”), pressing and holding down an alphanumeric key will cause that character to repeat until the key is released.

Delay The value assigned for this parameter determines the delay in milliseconds between repeat characters. The allowable values are: 150 ms, 200 ms, 250 ms, 300 ms, 350 ms, 400 ms, 450 ms and 500 ms.

124 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 151

Chapter 7: Setting Parameters Caps Lock On

Rate The value assigned for the “Rate” parameter determines how quickly the key you press repeats and is measured in characters per second (cps). The allowable values range from 1 cps to 10 cps.

Test This parameter is provided so that you can test the character repeat rate of your terminal. Once you’ve enabled (set to “Y”) the “Typematic rpt” parameter and assigned a “Delay” and “Rate” value, position your cursor in this field. Press and hold down an alphanumeric key to test the rate of character repeats.

7.5.5 Caps Lock On This parameter operates like the <CAPS LOCK> key on your PC keyboard. When “Caps Lock On” is set to “Y”, all alpha characters are displayed in uppercase. When this parameter is set to “N”, alpha characters are displayed in lowercase.

7.5.6 Panning Important:

The “Auto Pan” feature is modified using the parameters in this menu. Keep in mind, however, that “Auto Pan” is used by the DOS command line or by applications that do not provide auto panning (e.g., the Parameters menus). Tekterm is equipped with its own panning capabilities and does not execute panning as described in this section. Panning Auto pan Left margin Right margin Bottom margin X increment Y increment y 5 1 1 1 1

Range Y/N 0-25 0-25 0-20 0-25 0-25

Teklogix 7035, 8255 & 8260 Terminals User Manual

125

Page 152

Chapter 7: Setting Parameters Panning

Auto Pan, Left Margin, Right Margin And Bottom Margin Note: The “X increment” and “Y increment” parameters are used for manual panning only. Auto panning relies on the values set in the “Left margin”, “Right margin” and “Bottom margin” parameters. “Auto Pan” is used to enable and disable auto panning. When it is enabled (set to “Y”), the values set in the “Left Margin”, “Right Margin” and “Bottom Margin” are used to determine the number of characters that will always be visible to the left and right of the cursor and the number of lines that will always be visible below the cursor. If the cursor moves beyond the value specified, the entire contents of the screen are panned or shifted to comply with the values set in the margin parameters. Example: The value set in the “Left Margin” and “Right Margin” is 2. The value set in the “Bottom Margin” is 3. This specifies that 2 characters must always be displayed to the left and right of the cursor, and 3 lines must always be displayed below the cursor (Bottom Margin). The contents of the screen will not auto pan or shift until the cursor is moved past the minimum specified in a margin parameter. If the cursor is moved past the “Left Margin” setting, the screen pans to the right. If the cursor moves past the “Right Margin” setting, the screen pans to the left. If the cursor is moved beyond the “Bottom Margin” setting, the screen contents pan up.

X Increment And Y Increment Manual panning – shifting the contents of the screen using the <BLUE> key in combination with the <LEFT>, <RIGHT>, <UP> and <DOWN> arrow keys – relies on the values set in “X Increment” and “Y Increment” to determine the number of columns (spaces) and rows (lines) to pan or shift. “X Increment” determines the number of spaces the screen pans to the left or right when the <BLUE> key is pressed followed by the <LEFT> or <RIGHT> arrow key. “Y Increment” determines the number of lines the screen pans up or down when the <BLUE> key is pressed followed by the <UP> or <DOWN> arrow key.

126 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 153

Chapter 7: Setting Parameters Backlight

7.5.7 Backlight Backlight parameters vary depending on the type of terminal used – 7035 hand-held 8255 or 8260 vehicle-mount.

7.5.7.1 7035 Backlight Parameters Backlight Threshold 100 On Time 60 sec Intensity 0

Range 0..255 see text -5..5

Threshold The 7035 is equipped with automatic light sensing. The value entered in this parameter determines how dark the ambient light needs to be before the backlight turns on. The allowable range is 0 to 255. The higher the value, the darker the ambient light must be before the backlight turns on.

On Time The value entered in this parameter determines how long the backlight will stay on after a key is pressed, a scan is completed or data is received. “On Time” is measured in seconds. The allowable values are: Disabled, 5 secs, 10 secs, 15 secs, 20 secs, 30 secs, 60 secs and Always On. Choosing Disabled turns the backlight feature off. Choosing Always On sets the backlight to stay on constantly, whether or not a key is pressed or data is received.

Intensity This parameter is used to adjust the light intensity of the 7035 terminal screen. The allowable range is -5 to 5. The higher the value, the greater the screen light intensity.

Teklogix 7035, 8255 & 8260 Terminals User Manual

127

Page 154

Chapter 7: Setting Parameters 8255 And 8260 Backlight Parameters

7.5.7.2 8255 And 8260 Backlight Parameters Backlight Screen Always On Keyboard 10 secs

Range see text see text

Screen Important:

8255 terminals with vacuum fluorescent displays do not require a “Screen” backlighting option. They offer only the “Keyboard” backlighting option.

The value assigned for the “Screen” parameter determines how long the backlight will stay on after a key is pressed, a scan is completed or data is received. This parameter is measured in minutes. The allowable values are: Disabled, 10 secs, 15 secs, 20 secs, 30 secs, 45 secs, 1 min, 5 mins, 10 mins, 15 mins, 20 mins, 30 mins, 45 mins, 1 hour, 2 hours and Always On.

Choosing Always On sets the backlight to stay on constantly, whether or not a key is pressed or data is received.

Keyboard This parameter determines how long the keyboard backlight stays on after a key is pressed. The “Keyboard” parameter is measured in seconds and minutes. The allowable values are: Disabled, 5 secs, 10 secs, 20 secs, 30 secs, 1 min, 2 mins, 4 mins and Always On. Choosing Disabled turns off the keyboard backlight while Always On sets the backlight to stay on at all times.

128 Teklogix 7035, 8255 & 8260 Terminals User Manual