SETTING PARAMETERS
7
7.1 Using The Parameter Manager . . . . . . . . . . . . . . . . . . . . . . . . 113 7.2 Exiting Tekterm And Accessing The Display Menu . . . . . . . . . . . . . 113 7.3 Working With Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 7.3.1 Softkey Function Keys . . . . . . . . . . . . . . . . . . . . . . . . . 115 7.3.2 Displaying Sub-Menus. . . . . . . . . . . . . . . . . . . . . . . . . 116 7.3.3 Numeric Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 116 7.3.4 Y/N Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 7.3.5 Alpha Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 7.3.6 String Entry Parameters . . . . . . . . . . . . . . . . . . . . . . . . 117 7.3.6.1 Choosing An ASCII Character With The Arrow Keys . . . . .118 7.3.6.2 Adding Additional ASCII Characters . . . . . . . . . . . . .118 7.3.6.3 Entering Information In A String Entry Field . . . . . . . . .118 7.3.7 Saving Changes To Parameters . . . . . . . . . . . . . . . . . . . . 119 7.3.8 Resetting The Terminal . . . . . . . . . . . . . . . . . . . . . . . . 119 7.3.8.1 Resetting The 7035 . . . . . . . . . . . . . . . . . . . . . . .119 7.3.8.2 Resetting The 8255 And 8260 . . . . . . . . . . . . . . . . .119 7.3.9 Resetting Parameters To Default Values . . . . . . . . . . . . . . . . 119 7.4 Terminal Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 7.4.1 Displaying The Parameters Menu . . . . . . . . . . . . . . . . . . . 120 7.5 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 7.5.1 Volume And Contrast . . . . . . . . . . . . . . . . . . . . . . . . . 122 7.5.2 Key Click. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 7.5.3 One-Shot Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 7.5.4 Typematic Rpt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 7.5.5 Caps Lock On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 7.5.6 Panning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 7.5.7 Backlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 7.5.7.1 7035 Backlight Parameters . . . . . . . . . . . . . . . . . . .127 7.5.7.2 8255 And 8260 Backlight Parameters . . . . . . . . . . . . .128 7.5.8 Font Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Teklogix 7035, 8255 & 8260 Terminals User Manual
109
Page 136
Chapter 7: Setting Parameters
7.5.9 Cursor Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129 7.5.10 Palette Remap . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129 7.5.11 Watchdog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 7.5.12 Power – 7035 Only . . . . . . . . . . . . . . . . . . . . . . . . . .131 7.5.13 Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131 7.5.14 Keyboard Type – Vehicle-Mounts Only. . . . . . . . . . . . . . . .132 7.6 Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132 7.6.1 Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132 7.6.2 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133 7.6.2.1 Translate. . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 7.6.2.2 Other Options . . . . . . . . . . . . . . . . . . . . . . . . . 135 7.6.3 Barcode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137 7.6.3.1 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 7.6.3.2 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 7.6.3.3 EAN 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 7.6.3.4 EAN 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 7.6.3.5 UPC A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 7.6.3.6 UPC E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 7.6.3.7 Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 7.6.3.8 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 7.6.3.9 Code 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 7.6.3.10 I 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 7.6.3.11 MSI/PLESSY . . . . . . . . . . . . . . . . . . . . . . . . 146 7.6.3.12 D 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 7.6.3.13 IATA 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . 147 7.7 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 7.7.1 ANSI Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 7.7.1.1 Host Conn . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 7.7.1.2 Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 7.7.1.3 Host Char Set . . . . . . . . . . . . . . . . . . . . . . . . . 156 7.7.1.4 Transmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 7.7.1.5 Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 7.7.1.6 Serial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 7.7.2 TESS Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161 7.7.2.1 Host Conn . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 110 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 137
Chapter 7: Setting Parameters
7.7.2.2 Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 7.7.2.3 Characters . . . . . . . . . . . . . . . . . . . . . . . . . . .165 7.7.2.4 Serial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167 7.7.2.5 Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170 7.7.2.6 Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170 7.7.2.7 Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171 7.7.2.8 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . .173 7.8 View Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 7.9 GPS – Global Positioning System Receiver . . . . . . . . . . . . . . . . . 176 7.10 Ports– Serial 1 And Console 2 . . . . . . . . . . . . . . . . . . . . . . . 177 7.10.1 Serial 1 And Console 2 Peripheral Options. . . . . . . . . . . . . . 177 7.10.2 Serial 1 And Console 2 Parameter Settings. . . . . . . . . . . . . . 178 7.11 Global Macros. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 7.11.1 Displaying The Global Macros Menu . . . . . . . . . . . . . . . . 182 7.11.2 Displaying The Global Macros Table . . . . . . . . . . . . . . . . 183 7.11.3 Choosing An ASCII Character . . . . . . . . . . . . . . . . . . . . 184 7.11.4 Adding Additional ASCII Characters. . . . . . . . . . . . . . . . . 184 7.11.5 Programming Special Keys Into Macros . . . . . . . . . . . . . . . 185 7.12 Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 7.13 SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 7.14 Radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 7.15 Sound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 7.15.1 Vehicle-Mount ‘Sound’ Parameter Values . . . . . . . . . . . . . . 193 7.15.2 7035 Hand-Held ‘Sound’ Parameter Values . . . . . . . . . . . . . 194 7.17 ANSI FK Remap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 7.16 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 7.16.1 Sup. Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 7.16.2 Allow Teklogix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Teklogix 7035, 8255 & 8260 Terminals User Manual
111
Page 138
Page 139
Chapter 7: Setting Parameters Using The Parameter Manager
Important:
If you are uncertain how to operate your terminal keyboard, refer to Chapter 3: Keyboards – Operating Instructions beginning on page 47.
7.1 Using The Parameter Manager Warning:
Parameters should not be altered without a clear understanding of how they operate. Parameters that are incorrectly set can increase response time or cause communication difficulties. Generally, parameters are configured for each site during installation.
The Parameter Manager provides access to the parameter menus. The values assigned to the parameters can be viewed and adjusted to optimize communication at the site in which a terminal is operating. Note: Parameters can also be remotely modified using SNMP.
7.2 Exiting Tekterm And Accessing The Display Menu Normally, the Tekterm application is automatically launched when the terminal is turned on.
Exiting Tekterm To launch the Parameters menu, you first need to exit the Tekterm application: •
Press <ALT>, and type the letter x.
The start up “Display Menu” appears on the terminal screen. From this menu, you can launch the “Parameters” menu, relaunch the Tekterm application, or go to the DOS prompt. 01 Display Menu A Parameters B Emulations C DOS Prompt
Teklogix 7035, 8255 & 8260 Terminals User Manual
113
Page 140
Chapter 7: Setting Parameters Exiting Tekterm And Accessing The Display Menu
Launching The Display Menu To access any of these options, type the letter corresponding to the item you want to access. To launch the “Parameters” menu: •
Type the letter a.
A Password screen is displayed. Password
......
Note: A password is not requested when the terminal emulation application is launched. A Supervisory or a Psion Teklogix level password is required to access the complete “Parameters” menu or the DOS prompt. •
Type your supervisory level password. The default Sup. Password is 123456.
•
Press <ENTER>.
Important:
To protect against accidental changes to the terminal parameter settings and to limit user access, it is critical that you change this default supervisory level password immediately. Refer to “Security” on page 195 for details about personalizing your password.
114 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 141
Chapter 7: Setting Parameters Working With Menus
7.3 Working With Menus All terminal parameters are listed in menus. The <UP> and <DOWN> arrow keys are used to move the cursor up and down the current menu. The currently selected parameter name is displayed in reverse video. To help you work with the parameters and menus, a set of pre-programmed function keys – <F1> through <F4> – can be used to move back and forth between menus and save changes made to any parameters. There are four types of parameters: numeric, Y/N, alpha and string entry. In addition, some menus have sub-menus attached to them. This section of the manual describes how to work with all types of parameters and sub-menus.
7.3.1 Softkey Function Keys To speed the process of moving through menus and changing parameters, function keys <F1> to <F4> have been programmed to perform specific actions. Table 7.1 describes these function keys in the Parameter Manager.
Function Key
Softkey Function
<F1> <F2>
NEXT – Displays the next sub-menu PREV – Displays the previous menu. DEFLT – Restores ALL parameters to default settings – even after pressing <F4> to save the changes. SAVE – Saves the current set of parameter values.
<F3> <F4>
Table 7.1 Softkeys In The Parameter Manager
Teklogix 7035, 8255 & 8260 Terminals User Manual
115
Page 142
Chapter 7: Setting Parameters Displaying Sub-Menus
7.3.2 Displaying Sub-Menus The “»” character appearing to the right of the menu item indicates that it has a sub-menu.
Displaying Sub-Menus To display a sub-menu: •
Use the <UP> and <DOWN> arrow keys to position the cursor on the menu item with the sub-menu you want to display.
•
Press <F1> – the “NEXT” menu function key.
Returning To The Previous Menu •
Press <F2> – the “PREV” function key, or
•
Press <ESC>.
7.3.3 Numeric Parameters Numeric parameters are displayed in reverse video. To increment or decrement a number: •
Press the <RIGHT> or <LEFT> arrow keys, or
•
Type the desired number in the field. Negative values are entered by typing a “-” (minus) sign and then the number.
•
Press <ENTER>.
Each numeric parameter has a preset range of numbers assigned to it – for example, a preset range of 1 through 10. If you attempt to enter a number which either exceeds 10 or falls below 1, the incorrect value will be rejected – the original value for this parameter, if any, will be displayed.
116 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 143
Chapter 7: Setting Parameters Y/N Parameters
7.3.4 Y/N Parameters Y/N parameters can only be enabled (Y) or disabled (N). To enable or disable a Y/N parameter: •
Press the <RIGHT> or <LEFT> arrow key once, or
•
Type y to enable or n to disable the parameter.
Some Y/N parameters have sub-menus. For these parameters, a double right arrow (») appears next to the “Y” or “N”.
7.3.5 Alpha Parameters Alpha characters appear in reverse video in this type of parameter. The allowable values for this type of parameter consist of a predetermined set of acceptable letters or words. To cycle through the set: •
Press the <RIGHT> or <LEFT> arrow keys.
7.3.6 String Entry Parameters Important:
For detailed information about using string entry fields to program macro keys, refer to “Global Macros” on page 182.
A sequence or string of characters can be entered in this type of parameter. When a string entry parameter contains data, it is displayed in reverse video. (Empty fields are not displayed in reverse video.) The methods that can be used to enter information in string entry parameters are described in this section. In string entry parameters, the <UP> arrow, <DOWN> arrow, <ENTER> and <DEL> keys have the following functions: •
The <UP> and <DOWN> arrow keys move the cursor between entry fields in the direction of the arrow.
•
<ENTER> completes the entry field.
•
<DEL> deletes the character to the left of the cursor.
•
<CLR> (key combination <BLUE> <DEL>) clears the entire field.
Teklogix 7035, 8255 & 8260 Terminals User Manual
117
Page 144
Chapter 7: Setting Parameters Choosing An ASCII Character With The Arrow Keys
7.3.6.1 Choosing An ASCII Character With The Arrow Keys Important:
Make sure the <CTRL> and <SHIFT> keys are turned off!
By pressing either the <RIGHT> or <LEFT> arrow key, you can cycle through a set of printable characters not directly accessible from the keyboard. The ASCII sets differ slightly depending on the type of terminal you’re using.
7035: / < > % ^ & ` ~ | [ ] { } " ' ? = + ; 8255/8260: ^ & ‘ ~ | [ ] { } ’ " •
Press the <RIGHT> arrow to display the next character in this sequence, and the <LEFT> arrow to display the previous one.
7.3.6.2 Adding Additional ASCII Characters When you’ve chosen an ASCII character and want to add another one in the same field, the cursor must be moved to the right of the existing character. Normally, pressing the <RIGHT> arrow key moves the cursor to the right, but in a string entry field, pressing the <RIGHT> arrow key cycles through the available ASCII characters instead. If you’ve already chosen an ASCII character and want to add another one in the field, you need to take a few extra steps to move the cursor to the right. To add another ASCII character in the string entry field, next to the one you’ve already chosen: • •
Type a numeric character – for example, type the number 7. Next, press the <DEL> key
The cursor is now positioned to the right of the previously selected ASCII character. •
Press the <RIGHT> or <LEFT> arrow key to scroll through the ASCII characters, and select another character.
7.3.6.3 Entering Information In A String Entry Field In addition to using the fixed set of ASCII values assigned to this type of parameter, you can also type text in a string entry field. • •
Type the required text in the string entry field – including letters, numbers and symbols. Press <ENTER> to save the text.
118 Teklogix 7035, 8255 & 8260 Terminals User Manual