Page 215
Chapter 7: Setting Parameters Network
Grat Arp Max Ct The value assigned to this parameter determines the maximum number of sent gratuitous ARPs. It is recommended that this value remain at the default of 3 or slightly lower depending on your system.
Grat Arp RX Dly “Grat Arp RX Dly” determines the delay, in milliseconds, between gratuitous ARP retransmissions.
Simultan. Binds When this parameter is set to ‘Y’, it enables multiple (simultaneous) bindings. This means that the terminal can roam back to a Foreign Agent without registering again (assuming the old registration has not expired).
Max Num Binds The value assigned to ‘Max Num Binds’ represents the maximum number of bindings that the terminal will recognize at one time. When determining the value for this parameter, make certain that the maximum number of base stations that can be simultaneously accessed in the mobile node's (terminal’s) range are represented.
Foreign Agents The number assigned to this parameter represents the maximum number of Foreign Agents that can be stored locally at one time. While normally, the value assigned here should be fairly low (the default value is 10), it is critical that you set the value high enough so that the terminal always has access to a Foreign Agent and never loses contact with the host.
Home Agent SPI This parameter represents the Home Agent Security Parameter Index (SPI) assigned to the terminal’s Home Agent. In order for a terminal to communicate with a particular Home Agent, the value assigned here must match the SPI of the Home Agent. The default value is 333. Note: The minimum acceptable value is 256.
Home Agent Key The “Home Agent Key” is a 16 byte text string that acts as a password. In order for the terminal to communicate with the Home Agent, the terminal key must match the key assigned to the Home Agent. Teklogix 7035, 8255 & 8260 Terminals User Manual
189
Page 216
Chapter 7: Setting Parameters SNMP
Replay Protectn Setting this parameter to ‘Y’ enables time-stamp based replay protection. This prevents outside packets from infiltrating your system. The value assigned to the terminal must match the value set at the Home Agent.
802.IQ v2 802.IQ v2 Port
8888
Range see text
Port “Port” specifies the UDP port used by 802IQ v2. The default value is 8888. Keep in mind that the value assigned here must match the value set at the network controller. Note: When using 802IQ v2, make certain that the terminal “Net Mask” matches the network controller net mask.
7.13 SNMP SNMP Group Name Contact Name Location SNMP Enable Auth trap Communities Batt Thresh CQ Thresh
Y Y » 0 0
Range see text see text see text see text Y/N Y/N see text 0-100 0-100
Simple Network Management Protocol (SNMP) is the protocol used to monitor and manage devices attached to a TCP/IP network (providing they support SNMP). SNMP uses Management Information Bases (MIBs) that define the variables SNMP can access. Each product has a defined set of MIBs that determine how SNMP operates, the type of access allowed and so on. All Teklogix products support the TEKLOGIX-GENERIC-MIB – a MIB that defines some common features across Teklogix products. All devices also support MIB-II, a management information base that defines the common features of TCP/IP networks.
190 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 217
Chapter 7: Setting Parameters SNMP
Group Name The name assigned here allows MapRF users to group devices by a common name. This name is defined in the TEKLOGIX-GENERIC-MIB (refer to the introductory paragraph under the heading “SNMP” on page 190 for details about MIBs). The “Group Name” is also displayed on the terminal statistics screen.
Contact This field identifies the contact person for this managed node along with information about how to get in touch with this person.
Name The value assigned here is the name assigned by the network administrator for this managed node. Normally, this is the node's domain name.
Location This parameter is used to identify the physical location of this node (e.g., Warehouse A: Pillar 32B).
SNMP Enable When ‘SNMP Enable” is set to “Y”, the default value, SNMP functions are enabled. If SNMP is not used, set this parameter to “N” to disable this feature.
Auth Trap A trap is a report sent to SNMP managers when authorization failures occur. The value assigned to this parameter is defined in MIB-II. Setting the “Auth Trap” parameter to “Y” allows authorization traps to be sent when a failure is detected (e.g., an SNMP message received with a bad community name).
Communities Communities #1 » #2 » #3 » #4 » #5 » #6 »
Range see text
Teklogix 7035, 8255 & 8260 Terminals User Manual
191
Page 218
Chapter 7: Setting Parameters SNMP The “Communities” parameter provides a means of limiting access to SNMP managed devices. The “Communities” sub-menu allows the network administrator to determine the type of access allowed for each area name and IP address. Community Range Community Public see text IP Access Read RowStatus Active All SNMP messages carry a community name which is validated against a locally defined community table to allow certain kinds of access (e.g., Read or Read/Write access). Note: The community table is defined in TEKLOGIX-GENERIC-MIB. It can be accessed by SNMP and through the local Parameters menu.
Community This parameter displays the community name itself.
IP This parameter identifies the IP address. If the “Access” parameter indicates Read or Read/Write, a non-zero IP address will restrict the source of SNMP commands to be accepted only if they originate from the specified IP address. A null IP address can be accessed from any source. If the “Access” parameter has a value of TrapDest, the IP specifies the destination IP address for traps. Note that more than one trap destination can be configured.
Access The value assigned to the “Access” parameter determines the use of the community row. Read indicates that this community name provides read-only access to the variables. Read/Write means this community name can both read and write variables. Trap Dest indicates that this community row is only used to define a trap destination. Note that “IP” must also be set for these rows to be effective.
RowStatus “RowStatus” specifies the status of this row of the table. The allowable values include Active and NotInService. A row configured using the Parameters menu should always be set to Active.
192 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 219
Chapter 7: Setting Parameters Radio
Batt Thresh Note: This parameter is only available when the Teklogix security password is entered at startup. (‘Allow Teklogix’ must be set to “Y” – see page 195). The SNMP agent periodically polls the battery level and compares the level to the value assigned as the low battery threshold – “Batt Thresh. If the battery level is lower than the value assigned to the “Batt Thresh” parameter, a trap is sent only once until the battery level increases – presumably, when the battery has been replaced. This parameter is set to ‘0’ (zero) by default.
CQ Thresh Note: This parameter is only available when the Teklogix security password is entered at startup. (‘Allow Teklogix’ must be set to “Y” – see page 195). The SNMP agent polls the channel quality on a periodic basis and compares it to the value assigned as the low channel quality threshold – “CQ Thresh”. If the channel quality is lower than this threshold, a trap is sent only once until the channel quality increases to a recovery level. This parameter is set to ‘0’ (zero) by default.
7.14 Radio Refer to Appendix D: Radio Parameters for a detailed description of the parameters used to adjust radio communications.
7.15 Sound Note: The default values for “Beep tone”, “Error tone” and “Scan tone1, 2 and 3” vary between 7035 hand-helds and vehicle-mount terminals.
7.15.1 Vehicle-Mount ‘Sound’ Parameter Values Sound Beep tone Beep time Error tone Error time Scan tone 1 Scan time 1 Scan tone 2 Scan time 2 Scan tone 3 Scan time 3
2300 600
800 600 1250 150 2300 150 3750 150
Range 500-5000 0-2000 500-5000 0-2000 500-5000 0-2000 500-5000 0-2000 500-5000 0-2000
Teklogix 7035, 8255 & 8260 Terminals User Manual
193
Page 220
Chapter 7: Setting Parameters 7035 Hand-Held ‘Sound’ Parameter Values
7.15.2 7035 Hand-Held ‘Sound’ Parameter Values Sound Beep tone Beep time Error tone Error time Scan tone 1 Scan time 1 Scan tone 2 Scan time 2 Scan tone 3 Scan time 3
4300 600
3000 600 2600 150 3300 150 4750 150
Range 500-5000 0-2000 500-5000 0-2000 500-5000 0-2000 500-5000 0-2000 500-5000 0-2000
Beep Tone And Beep Time These parameters regulate the frequency and duration of beeps emitted in a TESS or ANSI session when one of the following is received at the terminal: an advisory, a hey you or a bell character. Tone is measured in hertz and time in milliseconds.
Error Tone And Error Time These parameters determine the frequency and duration of each error tone. Tone is measured in hertz and time in milliseconds.
Scan Tone 1 And Scan Time 1 “Scan tone 1” and “Scan time 1” determine the frequency and duration of the first beep of a multiple beep. Tone is measured in hertz and time in milliseconds.
Scan Tone 2 And Scan Time 2 “Scan tone 2” and “Scan time 2” determine the frequency and duration of the second beep of a multiple beep. Tone is measured in hertz and time in milliseconds.
Scan Tone 3 And Scan Time 3 “Scan tone 3” and “Scan time 3” determine the frequency and duration of the third beep of a multiple beep. Tone is measured in hertz and time in milliseconds.
194 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 221
Chapter 7: Setting Parameters Security
7.16 Security To change the default supervisory level password – the default is 123456 – for the terminal: •
Position the cursor on the ‘Security’ parameter and press <F1>. Security Range Sup. Password see text Allow Teklogix Y Y/N
7.16.1 Sup. Password •
At the ‘Sup. Password’ parameter, type a supervisory level password that will be easy for you to remember (but not easy for your colleagues to discover). The password can include a maximum of six alphabetic and/or numeric characters.
•
Press <F4> to save the new password.
Important:
Once you choose a password, it is critical that you set all the terminals to the same password, write down your password and keep it in a secure place. If you lose your password, your terminal parameters can only be changed by Psion Teklogix personnel. However, Psion Teklogix can only help you if the ‘Allow Teklogix’ parameter was set to “Y”. Refer to “Allow Teklogix” on page 195 for details.
7.16.2 Allow Teklogix Setting this parameter to “Y” allows Psion Teklogix personnel to use their support level password to access terminal parameters. If “Allow Teklogix” is set to “N”, only your supervisory level password can be used to access your terminal parameters. Warning:
If you set this parameter to “N”, the Psion Teklogix support level password will be rejected. Keep in mind that if you then lose your supervisory level password, you will need to clear the entire configuration setup on all terminals to gain access to the parameter menus.
Teklogix 7035, 8255 & 8260 Terminals User Manual
195
Page 222
Chapter 7: Setting Parameters ANSI FK Remap
7.17 ANSI FK Remap F 1 F 2 F 3 • • • F28 F29 F30
ANSI FK Remap = 1b 4f 50 = 1b 4f 51 = 1b 4f 52
= = =
1b 1b 1b
5b 5b 5b
34 34 34
00 00 00
Range see text
32 33 34
In ANSI, each function key – <F1> to <F36> – has a default string associated with it. When a function key is pressed, the corresponding default string is sent to the host. The “ANSI FK Remap” table allows these function key character sequences to be redefined. The remapped string length is limited to a maximum of 7. Important:
This menu is available only after the “FK Remap” parameter (see “FK Remap” on page 153) is set to “Y”.
196 Teklogix 7035, 8255 & 8260 Terminals User Manual