Page 131
Wand Emulation: Idle State = High Idle state refers to the TTL logic level of the Wand Emulation signal when not in use. When the idle state is high, the output signal is between 2.4 and 5.25 VDC, the standard TTL logic high range. Scan this bar code to set the idle to high.
6 R44-1740
400213
000011
127
Page 132
Wand Emulation: Label Format = Normal Mode Scan this bar code to instruct the scanner to send label data to the host in its original format without any translation.
6
128
400635
000002
Duet™ and VS800™ Scanner Programming Kit
Page 133
Wand Emulation: Label Format = Code 39 Scan this bar code to instruct the scanner to translate label data into Code 39 format before sending it to the host.
6 R44-1740
400635
000019
129
Page 134
Wand Emulation: Label Format = Code 39 Full ASCII Scan this bar code to instruct the scanner to translate label data into Code 39 full ASCII format before sending it to the host. Label data that is not in the Code 39 character set will be transmitted using full ASCII encoding.
6
130
400635
000033
Duet™ and VS800™ Scanner Programming Kit
Page 135
Wand Emulation: Label Format = Code 128 Scan this bar code to instruct the scanner to translate label data into Code 128 format before sending it to the host. The label will be rejected if it contains data that is not in the Code 128 character set.
6 R44-1740
400635
000026
131
Page 136
Wand Emulation: Leading Noise, Enable When this option is enabled, the scanner generates noise transitions prior to sending the label data to the host. This noise signal notifies the host that label data is coming. Scan this bar code to enable the feature.
6
132
400233
000015
Duet™ and VS800™ Scanner Programming Kit
Page 137
Wand Emulation: Leading Noise, Disable When this option is enabled, the scanner generates noise transitions prior to sending the label data to the host. This noise signal notifies the host that label data is coming. Scan this bar code to disable the feature.
6 R44-1740
400233
000008
133
Page 138
Keyboard Wedge Interface Configuration The following programming bar codes pertain only to POS terminals with a Keyboard Wedge communication interface. In order for the POS terminal and scanner to communicate, the scanner's configuration must match the communication settings of the POS terminal. Typically, the scanner's factory default configuration has been preset to match your POS terminal requirements. Keyboard Wedge interface communication options are: • Intercharacter Delay • Keyboard Support • Country/Language Selection • Caps Lock NOTE The Keyboard Wedge interface must first be selected (reference the Interface Selection section of this manual) before you can set the options in this section.
134
Duet™ and VS800™ Scanner Programming Kit
Page 139
Keyboard Wedge: Intercharacter Delay = 5ms. Scan this bar code to set the Keyboard Wedge intercharacter delay to 5 milliseconds (the minimum delay setting).
6 R44-1740
400647
000007
135
Page 140
Keyboard Wedge: Intercharacter Delay = 10ms. Scan this bar code to set the Keyboard Wedge intercharacter delay to 10 milliseconds.
6
136
400647
000106