Page 131

Wand Emulation: Idle State = High Idle state refers to the TTL logic level of the Wand Emulation signal when not in use. When the idle state is high, the output signal is between 2.4 and 5.25 VDC, the standard TTL logic high range. Scan this bar code to set the idle to high.

6 R44-1740

400213

000011

127

Page 132

Wand Emulation: Label Format = Normal Mode Scan this bar code to instruct the scanner to send label data to the host in its original format without any translation.

6

128

400635

000002

Duet™ and VS800™ Scanner Programming Kit

Page 133

Wand Emulation: Label Format = Code 39 Scan this bar code to instruct the scanner to translate label data into Code 39 format before sending it to the host.

6 R44-1740

400635

000019

129

Page 134

Wand Emulation: Label Format = Code 39 Full ASCII Scan this bar code to instruct the scanner to translate label data into Code 39 full ASCII format before sending it to the host. Label data that is not in the Code 39 character set will be transmitted using full ASCII encoding.

6

130

400635

000033

Duet™ and VS800™ Scanner Programming Kit

Page 135

Wand Emulation: Label Format = Code 128 Scan this bar code to instruct the scanner to translate label data into Code 128 format before sending it to the host. The label will be rejected if it contains data that is not in the Code 128 character set.

6 R44-1740

400635

000026

131

Page 136

Wand Emulation: Leading Noise, Enable When this option is enabled, the scanner generates noise transitions prior to sending the label data to the host. This noise signal notifies the host that label data is coming. Scan this bar code to enable the feature.

6

132

400233

000015

Duet™ and VS800™ Scanner Programming Kit

Page 137

Wand Emulation: Leading Noise, Disable When this option is enabled, the scanner generates noise transitions prior to sending the label data to the host. This noise signal notifies the host that label data is coming. Scan this bar code to disable the feature.

6 R44-1740

400233

000008

133

Page 138

Keyboard Wedge Interface Configuration The following programming bar codes pertain only to POS terminals with a Keyboard Wedge communication interface. In order for the POS terminal and scanner to communicate, the scanner's configuration must match the communication settings of the POS terminal. Typically, the scanner's factory default configuration has been preset to match your POS terminal requirements. Keyboard Wedge interface communication options are: • Intercharacter Delay • Keyboard Support • Country/Language Selection • Caps Lock NOTE The Keyboard Wedge interface must first be selected (reference the Interface Selection section of this manual) before you can set the options in this section.

134

Duet™ and VS800™ Scanner Programming Kit

Page 139

Keyboard Wedge: Intercharacter Delay = 5ms. Scan this bar code to set the Keyboard Wedge intercharacter delay to 5 milliseconds (the minimum delay setting).

6 R44-1740

400647

000007

135

Page 140

Keyboard Wedge: Intercharacter Delay = 10ms. Scan this bar code to set the Keyboard Wedge intercharacter delay to 10 milliseconds.

6

136

400647

000106

Duet™ and VS800™ Scanner Programming Kit