Page 121
OCIA: Host Commands, Enable The scanner can be configured to respond to host commands. Scan this bar code to enable scanner response to OCIA host commands.
6 R44-1740
400207
000010
117
Page 122
OCIA: Host Commands, Disable The scanner can be configured to respond to host commands. Scan this bar code to disable scanner response to OCIA host commands.
6
118
400207
000003
Duet™ and VS800™ Scanner Programming Kit
Page 123
OCIA: Beep On Not On File, Enable When enabled, this feature will cause the scanner to sound 21 Good Read Beeps upon receipt of a Not On File command from the host.
Note OCIA host commands must be enabled for this option to work (scan the OCIA: Host Commands, Enable bar code). Scan this bar code to enable the "beep on not on file" option.
6 R44-1740
401105
000010
119
Page 124
OCIA: Beep On Not On File, Disable Scan this bar code to disable the "beep on not on file" option.
6
120
401105
000003
Duet™ and VS800™ Scanner Programming Kit
Page 125
Wand Interface Configuration The following programming bar codes pertain only to POS terminals with the Wand Emulation communication interface. In order for the POS terminal and scanner to communicate, the scanner's configuration must match the communication settings of the POS terminal. Typically, the scanner's factory default configuration has been preset to match your POS terminal requirements. Wand interface communication options are: • • • • •
Polarity Signal Speed Idle State Label Format Leading Noise NOTE The Wand interface must first be selected (reference the Interface Selection section of this manual) before you can set the Wand options in this section.
R44-1740
121
Page 126
Wand Emulation: Polarity = …Bars Low Scan this bar code to set quiet zones and spaces high and bars low.
6
122
400212
000005
Duet™ and VS800™ Scanner Programming Kit
Page 127
Wand Emulation: Polarity = …Bars High Scan this bar code to set quiet zones and spaces low and bars high.
6 R44-1740
400212
000012
123
Page 128
Wand Emulation: Signal Speed = 330µs Scan this bar code to set signal speed at 330µs per nominal bar or space.
6
124
400214
000003
Duet™ and VS800™ Scanner Programming Kit
Page 129
Wand Emulation: Signal Speed = 660µs Scan this bar code to set signal speed at 660µs per nominal bar or space.
6 R44-1740
400214
000010
125
Page 130
Wand Emulation: Idle State = Low Idle state refers to the TTL logic level of the Wand Emulation signal when not in use. When the idle state is low, the output signal is between 0.0 and 0.7 VDC; the standard TTL logic low range. Scan this bar code to set the idle to low.
6
126
400213
000004
Duet™ and VS800™ Scanner Programming Kit