Page 289

EAN UCC Composite

EAN UCC Composite, continued EAN UCC Composite Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever an EAN UCC Composite bar code is scanned.

NOTE

The options in this section set Data Group Characters for the EAN UCC Composite symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).

To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET EAN UCC COMPOSITEDATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever an EAN UCC Composite bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.

Product Reference Guide

6-201

Page 290

Symbologies

EAN UCC Composite, continued START STATE

BARCODE

Set EAN UCC Composite Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET

END

6-202

QuickScan® QS6500/QS6500 BT

Page 291

Code 4/5

Code 4/5 The following options apply to the Code 4 and Code 5 symbologies.

Disable/Enable Code 4 and Code 5 When this feature is disabled, the imager will not read Code 4 or Code 5 bar codes.

Data Transmission Format Hex or decimal data transmission format may be selected.

START STATE

BARCODE

Disable Code 4/5 Enable Code 4/5 Hex Transmission Format Decimal Transmission Format END

Product Reference Guide

6-203

Page 292

Symbologies

Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted Code 4/5 bar code data depending on how this feature is enabled. Example: Setting the Code 4/5 Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the Code 4/5 symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “N” to represent Code 4/5. The value from the table corresponding to ‘’N’ is 4E, . This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET Code 4/5 I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’ and ‘E’ (the value determined in an earlier step to represent ‘N’), 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned Code 4/5 labels would appear as follows: Scanned bar code data:0123456789123 Resulting message string output:N0123456789123

6-204

QuickScan® QS6500/QS6500 BT

Page 293

Code 4/5

Code 4/5, continued START STATE

BARCODE

Set Code 4/5 Code I.D. Character(s) DEFAULT SETTING FOR THIS FEATURE: N (4E hex) Select 0000 to disable Code ID for this symbology only. SET

END

Product Reference Guide

6-205

Page 294

Symbologies

Code 4/5, continued Code 4/5 Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever a Code 4 or Code 5 bar code is scanned.

NOTE

The options in this section set Data Group Characters for Code 4/Code symbologies ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).

To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET CODE 4/5DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever Code 4 or Code 5 bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.

6-206

QuickScan® QS6500/QS6500 BT

Page 295

Code 4/5

Code 4/5, continued START STATE

BARCODE

Set Code 4/5 Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET