Page 297
Chapter 7
Bluetooth Features Features in this section are applicable only to Bluetooth (BT) models. The Bluetooth model includes an imager and Base Station. When the imager and Base Station are linked together, the imager will read and decode bar codes and transmit them via a Bluetooth radio to the Base Station. The Base Station will then transmit the bar code data to the POS host system over the host cable. The host interfaces available from the Base Station are the same set as the corded version of the product.
Auto Update When this feature is enabled, an imager and its linked Base Station can automatically ensure they stay in sync with regard to application hardware and/or configuration. This is accomplished by the linked imager and Base Station comparing application version number and configuration file check sum. If either is different, the Base Station will automatically update the imager with its application/configuration. If the units are linked, any changes made to the Base Station configuration through the scan utility software will automatically be sent to the imager at the completion of the programming session. By the same token, any changes made to the linked imager’s configuration will be transmitted to the Base Station at the end of the programming session. The following options are available for Auto Update:
•
Auto update enable, Allows both application and configuration updating.
•
Configure auto update enable, Allows only configuration updating.
•
Application auto update enable, Allows only application updating
•
Auto update disable, No automatic updates will be performed.
Product Reference Guide
7-1
Page 298
Bluetooth Features
Auto Update, continued START STATE
BARCODE
Auto Update Enable ³
1
0
0
Configure Auto Update Enable Application Auto Update Enable Auto Update Disable END
7-2
QuickScan® QS6500/QS6500BT
Page 299
Batch Mode
Batch Mode The imager can be programmed to store bar code data if it is reading bar code labels while out of range of the Base Station. The imager will read the bar code and give an indication that the label has been read but not transmitted. When the buffer is full, the imager will indicate any subsequent label reads with a bad read indication. When the imager is brought back in range of the Base Station, the stored labels will be transmitted to the Base Station automatically and the imager will indicate this with successful transmission beeps. The imager will store up to 1KB of label data while out of Base Station range. The number of labels that can be stored is completely dependent on the type and length of the labels and how much additional data is added to each label through the editing features available for this imager. Nominally, the imager will hold up to 60 UPC-A labels with a standard label ID and suffix setting.
Batch Mode will not function if the previous feature, Auto Update, is disabled. NOTE
START STATE
BARCODE
Disable Batch Mode Enable Batch Mode END
Product Reference Guide
7-3
Page 300
Bluetooth Features
Deep Sleep Mode The BT model of the imager can be placed into Deep Sleep Mode after this programmed duration (since the unit’s last scanning activity). Press its trigger to wake the imager from this mode. START DURATION
BARCODE
Disable
20 Seconds
30 Seconds
40 Seconds
50 Seconds
1 Minute
70 Seconds
80 Seconds
90 Seconds
100 Seconds END
7-4
QuickScan® QS6500/QS6500BT
Page 301
Leash Alarm
Leash Alarm When enabled, the Leash Alarm will force the imager to sound an alarm for a preprogrammed length of time to notify if an imager is leaving the immediate vicinity of the Base Station. This is especially useful in instances where the imager might inadvertently have been placed in a bag or cart. For this mode to be effective, Deep Sleep Mode must be disabled. If the imager is asleep, there is no way for it to know where it is relative to the Base Station because communication is not active between the devices. START DURATION
BARCODE
Disable Alarm
1 Second
2 Seconds
3 Seconds
4 Seconds
5 Seconds
6 Seconds
7 Seconds
8 Seconds
Product Reference Guide
7-5
Page 302
Bluetooth Features START DURATION
BARCODE
9 Seconds
10 Seconds
15 Seconds
20 Seconds
25 Seconds
30 Seconds
35 Seconds
40 Seconds
45 Seconds
50 Seconds
55 Seconds
60 Seconds END
7-6
QuickScan® QS6500/QS6500BT
Page 303
Bluetooth Connectivity Mode
Bluetooth Connectivity Mode The feature allows the imager to be linked to any Bluetooth (BT) enabled device which can accept such a connection with other devices. To implement this mode, follow these instructions: 1. Place the imager in Programming Mode by scanning the START bar code. 2. Scan the “Connect to a BT Device” bar code to put the imager in the mode enabling a link to a device other than its own Base Station. 3. Scan the END bar code to exit Programming Mode. 4. Scan the “Begin Pin” bar code. 5. Set the four- to six-character PIN code assigned to the target Bluetooth device using the bar codes available in Appendix B, AlphaNumeric Pad. 6. Scan the “End Pin” bar code. 7. Use the software that drives the other BT device to scan for devices in the area. The QS6500BT imager will be displayed as "PSC handheld scanner." Each BT device uses different methods to link, so you’ll need to follow the instructions for the device being connected to. The Serial Peripheral Protocol is the only interface supported. NOTE
Product Reference Guide
7-7
Page 304
Bluetooth Features
Bluetooth Connectivity Mode, continued START STATE
BARCODE
Connect to Base Station Connect to a BT Device END Begin Pin End Pin
7-8
QuickScan® QS6500/QS6500BT
Page 305
Inquiry Beep Control
Inquiry Beep Control When the Base Station is not linked to a handheld, the Radio LED will blink amber and the Base Station will beep. This beep can be disabled or reconfigured to sound for different durations by using the following programming bar codes. START STATE
BARCODE
Disable Inquiry Beep Inquiry Beep = 10 Seconds Inquiry Beep = 20 Seconds Inquiry Beep = 30 Seconds Inquiry Beep = 40 Seconds Inquiry Beep = 50 Seconds Inquiry Beep = 1 Minute Inquiry Beep = 1.5 Minutes Inquiry Beep = 2 Minutes Inquiry Beep = 3 Minutes Inquiry Beep = 4 Minutes
Product Reference Guide
7-9
Page 306
Bluetooth Features START STATE
BARCODE
Inquiry Beep = 5 Minutes Inquiry Beep = 6 Minutes Inquiry Beep = 7 Minutes Inquiry Beep = 8 Minutes END
7-10
QuickScan® QS6500/QS6500BT