Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 30 of 38

QuickScan QS6500/QS6500BT Product Reference Guide: Symbologies, pages 279 to 288

Pages 279 to 288 of 336, from QuickScan QS6500/QS6500BT Product Reference Guide

The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC QS6500BT and Datalogic QS6500BT Base

Page 279

Micro PDF 417

Micro PDF 417 The following options apply to the Micro PDF 417 symbology.

Disable/Enable Micro PDF 417 When this feature is disabled, the imager will not read Micro PDF 417 bar codes.

Escape Sequence Transmit Specifies transmission format of the escape sequence. START STATE

BARCODE

Disable Micro PDF417 Enable Micro PDF 417 Disable Escape Sequence Transmit GLI Escape Sequence Protocol ECI Escape Sequence Protocol END

Product Reference Guide

6-191

Page 280

Symbologies

Micro PDF 417, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.

NOTE

The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET

END

6-192

QuickScan® QS6500/QS6500 BT

Page 281

Micro PDF 417

Micro PDF 417, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted Micro PDF 417 bar code data depending on how this feature is enabled. Example: Setting the Micro PDF 417 Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the Micro PDF 417 symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “U” to represent Micro PDF 417. The value from the table corresponding to ‘’U’ is 55. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET MICRO PDF 417 I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘5’ and ‘5’ (the value determined in an earlier step to represent ‘U’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned Micro PDF 417 labels would appear as follows: Scanned bar code data:

0123456789123

Resulting message string output: U0123456789123

Product Reference Guide

6-193

Page 282

Symbologies

Micro PDF 417, continued START STATE

BARCODE

Set Micro PDF 417 Code I.D. Character(s) DEFAULT SETTING FOR THIS FEATURE: U (55 hex) Select 0000 to disable Code ID for this symbology only. SET

END

6-194

QuickScan® QS6500/QS6500 BT

Page 283

Micro PDF 417

Micro PDF 417, continued Micro PDF 417 Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever a Micro PDF 417 bar code is scanned.

NOTE

The options in this section set Data Group Characters for the Micro PDF 417 symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).

To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET MICRO PDF 417DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever a Micro PDF 417 bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.

Product Reference Guide

6-195

Page 284

Symbologies

Micro PDF 417, continued START STATE

BARCODE

Set Micro PDF 417 Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET END

6-196

QuickScan® QS6500/QS6500 BT

Page 285

EAN UCC Composite

EAN UCC Composite The following options apply to the EAN UCC Composite symbology.

Disable/Enable EAN UCC Composite When this feature is disabled, the imager will not read EAN UCC Composite bar codes.

UCC/EAN 128 Emulation When enabled, EAN UCC Composite bar codes will be translated to the UCC/EAN 128 label data format. START STATE Disable EAN UCC Composite Enable EAN UCC Composite Disable UCC/ EAN 128 Emulation Enable UCC/ EAN 128 Emulation

BARCODE

END

Product Reference Guide

6-197

Page 286

Symbologies

EAN UCC Composite, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.

NOTE

The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET

END

6-198

QuickScan® QS6500/QS6500 BT

Page 287

EAN UCC Composite

EAN UCC Composite, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted EAN UCC Composite bar code data depending on how this feature is enabled. Example: Setting the EAN UCC Composite Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the EAN UCC Composite symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “RC” to represent EAN UCC Composite. The value from the table corresponding to ‘’R’ is 52, for ‘C’, 43. These value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET EAN UCC COMPOSITE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘5’ and ‘2’ (the value determined in an earlier step to represent ‘R’), then the bar codes ‘4’ and ‘3’ to represent the letter ‘C’. 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned EAN UCC Composite labels would appear as follows: Scanned bar code data:

0123456789123

Resulting message string output: RC0123456789123 Product Reference Guide

6-199

Page 288

Symbologies

EAN UCC Composite, continued START STATE

BARCODE

Set EAN UCC Composite Code I.D. Character(s)

DEFAULT SETTING FOR THIS FEATURE: RC (5243 hex) Select 0000 to disable Code ID for this symbology only.

SET

END

6-200

QuickScan® QS6500/QS6500 BT