Interleaved 2 of 5
Interleaved 2 of 5, continued START STATE Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Checksum Transmission
BARCODE
END
Product Reference Guide
6-91
Page 180
Symbologies
Interleaved 2 of 5, continued Fixed Length Control One or two fixed lengths may be configured for Interleaved 2 of 5. Lengths must be even and must include any check digit that may be in the bar code. If Length 1 or Length 2 are set to non-zero values, the minimum and maximum length settings are ignored. To disable fixed lengths, set Length 1 and Length 2 to a value of 00. To configure this feature: 1. Determine the length settings needed for Fixed Length 1 and Fixed Length 2, then reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen lengths. Selectable lengths are from 0x00 to 0x64 (from 0 to 100 decimal). 2. Scan the START bar code below. 3. Scan either the Set Fixed Length 1 or Set Fixed Length 2 bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the hex digits representing the desired length. For example, scan 00 to disable the feature, or 0A to set the length to 10. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode.
6-92
QuickScan® QS6500/QS6500 BT
Page 181
Interleaved 2 of 5
Interleaved 2 of 5, continued START MODE
BARCODE DEFAULT SETTINGS FOR THIS FEATURE: 00 (None)
Set Fixed Length 1
Set Fixed Length 2
Scan the bar code above, then two digits from Appendix B, Alpha-Numeric Pad representing the desired length.
Scan the bar code above, then two digits from Appendix B, Alpha-Numeric Pad representing the desired length.
SET
END
Product Reference Guide
6-93
Page 182
Symbologies
Interleaved 2 of 5, continued Minimum/Maximum Code Length Many symbologies have their own maximum and minimum code length, which can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with lengths below the minimum or above the maximum will be rejected. If the maximum code length is set to zero, the global maximum is in effect. If the minimum code length is set to zero, the global minimum is in effect.
NOTE
Ensure that the minimum length setting is not greater than the maximum length setting; otherwise, all the labels of the symbology will be unreadable. You can set the same value for both minimum and maximum length to force decoding of only bar codes of a certain length.
START MODE
BARCODE
Set Maximum Length DEFAULT SETTING FOR THIS FEATURE: 0 (00 Hex) Set Minimum Length DEFAULT SETTING FOR THIS FEATURE: 6 (06 Hex) SET
END
6-94
QuickScan® QS6500/QS6500 BT
Page 183
Interleaved 2 of 5
Interleaved 2 of 5, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.
NOTE
The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.
START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET
END
Product Reference Guide
6-95
Page 184
Symbologies
Interleaved 2 of 5, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted Interleaved 2 of 5 bar code data depending on how this feature is enabled. Example: Setting the Interleaved 2 of 5 Code I.D.
To configure this feature: 1. Determine which character(s) you would like to use to represent the Interleaved 2 of 5 symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “i” to represent Interleaved 2 of 5. The value from the table corresponding to ‘’i’ is 69. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET INTERLEAVED 2 of 5 CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘6’ and ‘9’ (the value determined in an earlier step to represent ‘i’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE
7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned Interleaved 2 of 5 labels would appear as follows: Scanned bar code data:
0123456789123
Resulting message string output: i0123456789123
6-96
QuickScan® QS6500/QS6500 BT
Page 185
Interleaved 2 of 5
Interleaved 2 of 5, continued START STATE
BARCODE
Set I 2 of 5 Code I.D. Character(s) DEFAULT SETTING FOR THIS FEATURE: i (69 hex) Select 0000 to disable Code ID for this symbology only. SET
END
Product Reference Guide
6-97
Page 186
Symbologies
Interleaved 2 of 5, continued Interleaved 2 of 5 Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever an Interleaved 2 of 5 bar code is scanned.
NOTE
The options in this section set Data Group Characters for the Interleaved 2 of 5 symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).
To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET INTERLEAVED 2 OF 5 DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever an Interleaved 2 of 5 bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.
6-98
QuickScan® QS6500/QS6500 BT
Page 187
Interleaved 2 of 5
Interleaved 2 of 5, continued START STATE
BARCODE
Set Interleaved 2 of 5 Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET
END
Product Reference Guide
6-99
Page 188
Symbologies
Industrial 2 of 5 The following options apply to the Industrial 2 of 5 (I 2 of 5) symbology.
Disable/Enable Industrial 2 of 5 When this feature is disabled, the imager will not read Industrial 2 of 5 bar codes. START STATE Disable Industrial 2 of 5 Enable Industrial 2 of 5