Page 169

Code 128

Code 128, continued START STATE

BARCODE

Disable Code 128 Enable Code 128 Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Checksum Transmission Disable Function Code Transmission Enable Function Code Transmission END

Product Reference Guide

6-81

Page 170

Symbologies

Code 128, continued Minimum/Maximum Code Length Many symbologies have their own maximum and minimum code length, which can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with lengths below the minimum or above the maximum will be rejected. If the maximum code length is set to zero, the global maximum is in effect. If the minimum code length is set to zero, the global minimum is in effect.

NOTE

Ensure that the minimum length setting is not greater than the maximum length setting; otherwise, all the labels of the symbology will be unreadable. You can set the same value for both minimum and maximum length to force decoding of only bar codes of a certain length.

START MODE

BARCODE

Set Maximum Length DEFAULT SETTING FOR THIS FEATURE: 0 Set Minimum Length DEFAULT SETTING FOR THIS FEATURE:0 SET

END

6-82

QuickScan® QS6500/QS6500 BT

Page 171

Code 128

Code 128, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.

NOTE

The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET

END

Product Reference Guide

6-83

Page 172

Symbologies

Code 128, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted Code 128 bar code data depending on how this feature is enabled. Example: Setting the Code 128 Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the Code 128 symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “#” (the pound sign) to represent Code 128. The value from the table corresponding to ‘’#’ is 23. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET CODE 128 CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘2’ and ‘3’ (the value determined in an earlier step to represent ‘#’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned Code 128 labels would appear as follows: Scanned bar code data:

0123456789123

Resulting message string output: #0123456789123

6-84

QuickScan® QS6500/QS6500 BT

Page 173

Code 128

Code 128, continued START STATE

BARCODE

Set Code 128 Code I.D. Character(s) DEFAULT SETTING FOR THIS FEATURE: # (23 hex) Select 0000 to disable Code ID for this symbology only. SET END

Product Reference Guide

6-85

Page 174

Symbologies

Code 128, continued Code 128 Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever a Code 128 bar code is scanned.

NOTE

The options in this section set Data Group Characters for the Code 128 symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).

To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET CODE 128 DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever a Code 128 bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.

6-86

QuickScan® QS6500/QS6500 BT

Page 175

Code 128

Code 128, continued START STATE

BARCODE

Set Code 128 Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET

END

Product Reference Guide

6-87

Page 176

Symbologies

EAN-128 Format as EAN-128 When this feature is enabled, the imager will translate Code 128 data strings starting with "FNC1" character to the UCC/EAN-128 data format. The first "FNC1" character will be translated to "]C1", and any following "FNC1" characters will be translated to "<GS>(1Dhex)".

Append When the function is enabled, the imager will store, but not immediately show data read as long as bar codes include the FNC2 code. This stored data will be displayed when a bar code is encountered which doesn't include the FNC2 code. START STATE Format as Standard Code 128

BARCODE

Format as UCC/EAN 128 Disable Append Enable Append END

6-88

QuickScan® QS6500/QS6500 BT

Page 177

EAN-128

EAN-128, continued UCC/EAN-128 ID setting Specifies UCC/EAN-128 label ID (2 bytes) to be added to label data.

START MODE

BARCODE

UCC/EAN-128 ID Setting DEFAULT SETTING FOR THIS FEATURE: None SET

END

Product Reference Guide

6-89

Page 178

Symbologies

Interleaved 2 of 5 The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbology.

Disable/Enable Interleaved 2 of 5 When this feature is disabled, the imager will not read Interleaved 2 of 5 bar codes.

Checksum Verification When enabled, the imager will verify the checksum of the labels.

Checksum Transmit Enable this option to transmit the checksum with scanned bar code data.

6-90