Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 18 of 38

QuickScan QS6500/QS6500BT Product Reference Guide: Symbologies, pages 159 to 168

Pages 159 to 168 of 336, from QuickScan QS6500/QS6500BT Product Reference Guide

The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC QS6500BT and Datalogic QS6500BT Base

Page 159

Code 39

Code 39, continued Format Use this feature to select standard or Full ASCII Code 39, which is an enhanced set of Code 39 and uses a total of 128 characters to represent Full ASCII code. Each Full ASCII Code 39 character is a combination of one of the characters +,%, $ and / with an uppercase alphabetical character (A to Z).

Append This function allows several symbols to be concatenated and be treated as a single entry. The imager will not transmit the embedded appending code (for Code-39, a space). If the append function is enabled and other symbols are read again with the appended code, then the codes are transmitted without the code ID, preamble, or prefix. When a symbol was decoded without the appended code, the data is transmitted without the code ID and prefix, but the postamble suffix codes are appended. This function is used when the first character of Code 39 data is a space.

Start/End Transmission The start and end characters of Code 39 are asterisks (*). You can transmit all data digits, including the two asterisks.

Product Reference Guide

6-71

Page 160

Symbologies

Code 39, continued START STATE

BARCODE

Standard Code 39 Full ASCII Code 39 Disable Append Enable Append Disable Start/End Transmission Enable Start/End Transmission END

6-72

QuickScan® QS6500/QS6500 BT

Page 161

Pharmacode 39

Pharmacode 39 The following options apply to the Pharmacode 39 symbology.

Disable/Enable Pharmacode 39 When this feature is disabled, the imager will not read Pharmacode 39 bar codes.

Leading ‘A’ When this option is enabled, a letter A is appended to the leading end of Pharmacode 39 bar code data. Scanned bar code data:

0123456789123

Resulting message string output:

A0123456789123

START STATE Disable Pharmacode 39

BARCODE

Enable Pharmacode 39 Disable Leading ‘A’ Enable Leading ‘A’ END

Product Reference Guide

6-73

Page 162

Symbologies

Pharmacode 39, continued Minimum/Maximum Code Length Many symbologies have their own maximum and minimum code length, which can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with lengths below the minimum or above the maximum will be rejected. If the maximum code length is set to zero, the global maximum is in effect. If the minimum code length is set to zero, the global minimum is in effect.

NOTE

Ensure that the minimum length setting is not greater than the maximum length setting; otherwise, all the labels of the symbology will be unreadable. You can set the same value for both minimum and maximum length to force decoding of only bar codes of a certain length.

START MODE

BARCODE

Set Maximum Length DEFAULT SETTING FOR THIS FEATURE:12 (0C hex) Set Minimum Length DEFAULT SETTING FOR THIS FEATURE:9 (09 hex) SET

END

6-74

QuickScan® QS6500/QS6500 BT

Page 163

Pharmacode 39

Pharmacode 39, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.

NOTE

The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET

END

Product Reference Guide

6-75

Page 164

Symbologies

Pharmacode 39, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted Pharmacode 39 bar code data depending on how this feature is enabled. Example: Setting the Pharmacode 39 Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the Pharmacode 39 symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “A” to represent Pharmacode 39. The value from the table corresponding to ‘’A’ is 41. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET PHARMACODE 39 CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’ and ‘1’ (the value determined in an earlier step to represent ‘A’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned Pharmacode 39 labels would appear as follows: Scanned bar code data:

0123456789123

Resulting message string output: A0123456789123

6-76

QuickScan® QS6500/QS6500 BT

Page 165

Pharmacode 39

Pharmacode 39, continued START STATE

BARCODE

Set Pharmacode 39 Code I.D. Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex) Select 0000 to disable Code ID for this symbology only. SET

END

Product Reference Guide

6-77

Page 166

Symbologies

Pharmacode 39, continued Pharmacode 39 Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever a Pharmacode 39 bar code is scanned.

NOTE

The options in this section set Data Group Characters for the Pharmacode 39 symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).

To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET PHARMACODE 39 DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever a Pharmacode 39 bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.

6-78

QuickScan® QS6500/QS6500 BT

Page 167

Pharmacode 39

Pharmacode 39, continued START STATE

BARCODE

Set Pharmacode 39 Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET

END

Product Reference Guide

6-79

Page 168

Symbologies

Code 128 The following options apply to the Code 128 symbology.

Disable/Enable Code 128 When this feature is disabled, the imager will not read Code 128 bar codes.

Checksum Verification When enabled, the imager will verify the checksum of the labels.

Checksum Transmit Enable this option to transmit the checksum with scanned bar code data.

Function Code Transmission Enable this option to transmit the Code 128 function characters 1,2,3 and 4 as hexadecimal values 80,81, 82 and 83 respectively. This feature is disabled from the factory for all interfaces except Wand Emulation.

6-80

QuickScan® QS6500/QS6500 BT