QuickScan QS6500/QS6500BT Product Reference Guide: Symbologies, pages 189 to 198

Pages 189 to 198 of 336, from QuickScan QS6500/QS6500BT Product Reference Guide

The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC QS6500BT and Datalogic QS6500BT Base

Page 189

Industrial 2 of 5

Industrial 2 of 5, continued Minimum/Maximum Code Length Many symbologies have their own maximum and minimum code length, which can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with lengths below the minimum or above the maximum will be rejected. If the maximum code length is set to zero, the global maximum is in effect. If the minimum code length is set to zero, the global minimum is in effect.

NOTE

Ensure that the minimum length setting is not greater than the maximum length setting; otherwise, all the labels of the symbology will be unreadable. You can set the same value for both minimum and maximum length to force decoding of only bar codes of a certain length.

START MODE

BARCODE

Set Maximum Length DEFAULT SETTING FOR THIS FEATURE: 0 (00 Hex) Set Minimum Length DEFAULT SETTING FOR THIS FEATURE: 0 (00 Hex) SET

END

Product Reference Guide

6-101

Page 190

Symbologies

Industrial 2 of 5, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.

NOTE

The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET

END

6-102

QuickScan® QS6500/QS6500 BT

Page 191

Industrial 2 of 5

Industrial 2 of 5, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted Industrial 2 of 5 bar code data depending on how this feature is enabled. Example: Setting the Industrial 2 of 5 Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the Industrial 2 of 5 symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “i” to represent Industrial 2 of 5. The value from the table corresponding to ‘’i’ is 69. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET INDUSTRIAL 2 of 5 CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘6’ and ‘9’ (the value determined in an earlier step to represent ‘i’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned Industrial 2 of 5 labels would appear as follows: Scanned bar code data:

0123456789123

Resulting message string output: i0123456789123

Product Reference Guide

6-103

Page 192

Symbologies

Industrial 2 of 5, continued START STATE

BARCODE

Set Code 39 Code I.D. Character(s) DEFAULT SETTING FOR THIS FEATURE: i (69 hex) Select 0000 to disable Code ID for this symbology only. SET END

6-104

QuickScan® QS6500/QS6500 BT

Page 193

Industrial 2 of 5

Industrial 2 of 5, continued Industrial 2 of 5 Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever an Industrial 2 of 5 bar code is scanned.

NOTE

The options in this section set Data Group Characters for the Industrial 2 of 5 symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).

To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET INDUSTRIAL 2 OF 5 DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever an Industrial 2 of 5 bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.

Product Reference Guide

6-105

Page 194

Symbologies

Industrial 2 of 5, continued START STATE

BARCODE

Set Industrial 2 of 5 Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET

END

6-106

QuickScan® QS6500/QS6500 BT

Page 195

Matrix 2 of 5 (Eur)

Matrix 2 of 5 (Eur) The following options apply to the Matrix 2 of 5symbology.

Disable/Enable Matrix 2 of 5 When this feature is disabled, the imager will not read Matrix 2 of 5 bar codes.

Checksum Verification When enabled, the imager will verify the checksum of the labels.

Checksum Transmit Enable this option to transmit the checksum with scanned bar code data.

Product Reference Guide

6-107

Page 196

Symbologies

Matrix 2 of 5 (Eur), continued START STATE

BARCODE

Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Checksum Transmission END

6-108

QuickScan® QS6500/QS6500 BT

Page 197

Matrix 2 of 5 (Eur)

Matrix 2 of 5 (Eur), continued Minimum/Maximum Code Length Many symbologies have their own maximum and minimum code length, which can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with lengths below the minimum or above the maximum will be rejected. If the maximum code length is set to zero, the global maximum is in effect. If the minimum code length is set to zero, the global minimum is in effect.

NOTE

Ensure that the minimum length setting is not greater than the maximum length setting; otherwise, all the labels of the symbology will be unreadable. You can set the same value for both minimum and maximum length to force decoding of only bar codes of a certain length.

START MODE

BARCODE

Set Maximum Length DEFAULT SETTING FOR THIS FEATURE: 00 Set Minimum Length DEFAULT SETTING FOR THIS FEATURE: 00 SET

END

Product Reference Guide

6-109

Page 198

Symbologies

Matrix 2 of 5 (Eur), continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.

NOTE

The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET

END

6-110