Page 9

Interfaces The QS2500 supports four interfaces, Keyboard Wedge, RS-232, Wand Emulation, IBM and USB. The correct interface cable is included for the scanner interface type you ordered.

Keyboard Wedge As a keyboard interface, the QS2500 supports most popular PCs and IBM terminals. The installation of the wedge is a fairly simple process that doesn’t require any changes of software or hardware. Keyboard Type: Select the keyboard type connector for your host computer. Keyboard Layout: The Keyboard Layout option supports many languages.

For details about keyboard languages, please refer to your operating system manual. Keyboard Speed: You can change the output speed of the QS2500 to match that of the host computer. Generally, set 00 or 01 for high speed. If output characters of bar codes get lost, you may need to set a slower speed. Start Program

Option Bar Code

Keyboard Type

Product Reference Guide

Option

Alphanumeric Entry

IBM AT, PS/2

00*

Reserved

01 - 06

5

Page 10

Option Bar Code

Keyboard Layout

Keyboard Speed

Option

Alphanumeric Entry

USA

00*

Belgium

01

Danish

02

France

03

Germany

04

Italian

05

Portuguese

06

Spanish

07

Swedish

08

Switzerland

09

UK

10

Latin American

11

Japan

12

0–8 (0 = high clock rate; 8 = low clock rate)

00–08 01*

Exit $ $

Function Key: When this option is enabled, the QS2500 outputs bar code

ASCII values from 01hex to 1Fhex as function-key presses in your application. See the table of ASCII codes In Appendix C on page 64. Numeric Key: If your application accepts only keypad numeric code, use setting 01 to make the QS2500 output code as numeric-keypad presses when it reads digits. If you use setting 02, the scanner will send the three digit ACSCII number for all data using the Alt and numeric keypad keycodes. Setting 02 prevents the caps Lock from affecting scanner data.

Page 11

Caps Lock: By selecting Caps Lock or No Caps Lock, the QS2500 can get

Caps Lock status. Power-On Simulation: All PCs check the keyboard status during the power-on selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on. Intercharacter Delay: This delay is inserted after each data character transmitted. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly. Block Transmission Delay: This is a delay timer between bar code data outputs. The feature is used to transfer continually with shorter bar code data or multifield scanning.

Product Reference Guide

7

Page 12

Start Program $

Option Bar Code

Function Key

Numeric Key

Caps Lock

Power-On Simulation

Option

Alphanumeric Entry

Disable

00*

Enable

01

Alphabetic key

00*

Numeric keypad only

01

Alt+Keypad

02

Caps lock

00

No caps lock

01*

Disable

00*

Enable

01

0–99 (msec.)

00–99 02*

Intercharacter Delay 0–99 (10 msec.) Block Transmission Delay

00–99 10* Exit

$ $

Page 13

Wand Emulation

Start Program $

Option

Alphanumeric Entry

Keyboard Wedge

00*

Wand Emulation

01

Bar high/Space low

00*

Bar low/Space high

01

Idle low

00*

Idle high

01

660

00

1250

01

2500

02

5000

03*

10000

04

20000

05

15 (Default) 00–99 (x 10 pixels)

15* 00–99

Option Bar Code

Interface selection

Bar/Space Polarity

Idle Polarity

Output Speed (pixels per second)

Margin Delay (pixels)

Transmit Delay (Milliseconds)

30 (default) 00–99 (x 10 msec.)

30* 00–99 Exit

$ $

Product Reference Guide

9

Page 14

CTS = Clear To Send (Hardware Signal) RTS = Request To Send (Hardware Signal) Xon = Transmit On (ASCII Code 11hex) Xoff = Transmit Off (ASCII Code13hex) ACK = Acknowledge (ACSII Code 06hex) NAK = Not Acknowledge (ASCII Code 15hex)

None: The communication uses only TxD and RxD signals, without regard for any hardware or software handshaking protocol. RTS/CTS: If the QS2500 wants to send the bar code data to the host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication. If there is no replied CTS signal from the host computer after the timeout (response delay) duration, the QS2500 will issue five warning beeps. Xon/Xoff: When the host computer is unable to accept data, it sends an

Xoff code to inform the QS2500 to suspend data transmission and an Xon to continue. ACK/NAK: When the ACK/NAK protocol is used, the QS2500 waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after data transmission. It then resends the data in response to a NAK. Intercharacter Delay: This is the delay time between outputs of data character. It is the same as the intercharacter delay of the keyboard wedge. Block Transmission Delay: This is the delay time between outputs of bar code data. It is the same as the block transmission delay of the keyboard wedge. Response Delay: This delay is used for serial communication. It is the amount of time the QS2500 waits for handshaking acknowledgment from the host computer.

Page 15

PSC Aux. Port: This configures the QS2500 flow control to connect to the

Auxiliary (AUX) port of some PSC omni-directional scanners. The QS2500 will assert RTS high to signal the scanner that data will be sent immediately after RTS is asserted. When connecting to a PSC scanner aux. port, additional programming is required to enable transmission of code IDs for all symbologies to be scanned. Mode B: This configures the RS-233 flow control to communicate to some Wincor (SNI) terminals. Start Program $

Option Bar Code

Flow Control

Alphanumeric Entry

Option None

00*

RTS/CTS

01

Xon/Xoff

02

ACK/NAK

03

PSC Aux. Porta

04

Mode B

05

0–99 (msec.)

00–99 00*

Intercharacter Delay 0–99 (10 msec.) Block Transmission Delay 0–99 (100 msec.) Response Delay

00–99 00* 00–99 20*

Page 16

Option Bar Code

Baud Rate

Parity

Data Bit

Stop Bit

Option

Alphanumeric Entry

300 Baud

00

600 Baud

01

1200 Baud

02

2400 Baud

03

4800 Baud

04

9600 Baud

05*

19200 Baud

06

38400 Baud

07

None

00*

Odd

01

Even

02

8 bits

00*

7 bits

01

1 bit

00*

2 bits

01 Exit $ $ a. Reading PDF417 through the Aux. Port is host dependent.

-

Page 17

IBM Interface The next few pages contain the programming labels for configuring the IBM interface to match your interface configuration and symbology specific requirements. Start Program

Option Bar Code

Option

Alphanumeric Entry

IBM 46xx port 17

00

IBM 46xx port 5B

01

IBM 46xx port 9B

02

IBM USB

03

Exit

IBM 46xx Code 39 Conversion This feature enables/disables the scanner’s ability to set the symbology identifier for the specified symbology to Code 39 before sending the label data to an IBM host. This applies to: Code 128, Code 93 and Codabar for IBM Port 5B; Code 93 and Codabar for IBM Port 9B.

This feature is for IBM port 5B and IBM port 9B.

NOTES

IBM-USB Device Type The IBM-USB protocol allows for the scanner to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a IBM-USB POS, you may need to change this setting to enable all scanners to communicate. Options are: • •

Product Reference Guide

Table Top Scanner Handheld Scanner

13

Page 18

This feature applies only to the IBM USB interface.

NOTES

IBM Maximum Host-Transmitted Message Length Specifies the maximum number of data characters allowed in messages transmitted to an IBM host.

If this configuration item is set to zero, there is no general length limit imposed on data being transmitted to the host.

NOTES

Start Program

Option Bar Code

Option Disable

IBM 46xx Code 39 Conversion

IBM USB Device Type

Alphanumeric Entry 00*

Enable 01 Table-top

00

Handheld

01*

0x00–0xF6 Max. Host Transmit Message Length

00*

Exit

14