Page 19

Scanning Scanning Mode Good-read off: The trigger button must be pressed to activate scanning.

The light source of the QS2500 stops scanning when there is a successful read or no code is decoded after the standby duration has elapsed. Momentary: The trigger button acts as a switch. Pressing the button activates scanning and releasing the button stops scanning. Alternate: The trigger button acts as a toggle switch. Pressing the button activates or stops scanning. Timeout off: The trigger button must be pressed to activate scanning, and the QS2500 stops scanning when no code is decoded after the standby duration has elapsed. Continue: The QS2500 always keeps reading, and it does not matter whether the trigger button is pressed or the standby duration has elapsed. Select this mode for use in Stand Mode. Test only: The QS2500 always keeps a constant reading, and same-label reading is allowed without double confirmation. The feature can test the performance of the QS2500 for reading speed and sensitivity. Standby Duration: A timeout duration of 1 to 99 seconds can be set. It is effective only when the CCD scanning mode is operated in timeout-off mode and good-read off mode. Same Bar Code Delay Time: If the bar code has been scanned twice, then only the first bar code will be accepted. Double Confirm: If this option is enabled, the QS2500 will require a several successful decodings to confirm the bar code data. Larger settings will make misreads less likely. If a double confirm is set, the multifield scan function will be disabled. Multifield Scan: The QS2500 can be read many sets of bar code data on the same scanning line at the same time, even if they are different kinds of bar code symbology.

Product Reference Guide

15

Page 20

Start Program

Option Bar Code

Scanning Mode

Option Good-read off

00

Momentary

01*

Alternate

02

Timeout off

03

Continue/Scan Mode

04

Test only

05

0–99 (sec.)

01–99 10*

Standby Duration 0–99 (10 msec.) Same Bar Code Delay Time

Double Confirm

Multifield Scan

Alphanumeric Entry

01–99 50*

0–99 (0 = no double confirm)

00–09 00*

Disable

00*

Enable

01 Exit $ $

Page 21

Global Minimum/Maximum Code Length: Global minimum and maximum length can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with length exceeding these limits will be rejected. Make sure that the minimum-length setting is no greater than the maximum-length setting; otherwise, the labels of the symbology will not be readable. In particular, you can set the same value for both minimum and maximum lengths to force decoding of only fixed-length bar codes. This setting has no effect on certain symbologies of fixed length.

Set the minimum/maximum length if you have a special demand for individual bar codes. Include the checksum digits if you want to set global minimum/maximum code length. NOTE Inverted Image Scan: With this option enabled, the QS2500 will scan black/white bar codes with a white/black background. CTS Trigger: This operation enables an external device to control scanning by applying an external trigger signal to the CTS input. When active, this signal causes scanning to begin as the QS2500’s trigger is depressed. Visible Scan Field Indicator: This function allows a visible indicator to be emitted when the trigger is pulled. Start Program

Option Bar Code

Option 0–63

Global Minimum Code Length 0–63 Global Maximum Code Length

Product Reference Guide

Alphanumeric Entry 00–63 04*

00–63 63*

17

Page 22

Option Bar Code

Inverted Image Scan

CTS Trigger

Visible Scan Field Indicator

Option

Alphanumeric Entry

Disable

00*

Enable

01

Disable

00*

Enable

01

Disable

00*

30 second

01

60 second

02

90 second

03

120 second

04

150 second

05

180 second

06

Continuous

07 Exit $ $

Beep/Tone/LED Settings Power-On Alert: After power-on, the QS2500 will generate an alert signal to indicate a successful self-test. LED Control: After each successful bar code reading, the LED above the QS2500 will light up. Beep Control: After each successful bar code reading, the QS2500 will beep. Beep Loudness/Beep-Tone Frequency/Beep-Tone Duration: You can adjust the loudness, tone, and duration of the good-read beep.

18

QS2500

Page 23

Start Program

Option Bar Code

Power-On Alert

LED Indication

Beeper Indication

Option Disable

00

Enable

01*

Disable

00

Enable

01*

Disable

00

Enable

01*

0–07

00–07 03*

0–99 (100Hz)

00–99 26*

0–99 (10 msec.)

00–99 10*

Disable

00

Enable

01*

Disable

00

Beep Loudness

Beep-Tone Frequency

Beep-Tone Duration Beep/Lamp Option 1:

Beep & LED after decode Beep/Lamp Option 2:

Beep & LED after data transmission

Enable

Disable Beep/Lamp Option 3:

Beep & LED after data transmission & CTS active

Alphanumeric Entry

Enable

01 00 01 Exit

Product Reference Guide

19

Page 24

Label Editing (includes Prefix/Suffix) Prefix Characters: Up to 22 ASCII characters may be sent before data. Prefix

Data

Suffix

Suffix Characters: Up to 22 ASCII characters may be sent after data. Preamble/Postamble Characters: These characters are affixed to the data automatically when each bar code is decoded. Example: Add a prefix/suffix or preamble/postamble for all symbologies. In this example, you can send a ‘$’ symbol as a prefix for all symbologies by completing the following steps: 1. Scan the Start Program and Prefix Characters Setting bar codes below. 2. Use the ASCII code table (see Appendix C - page 64) to find the ASCII value for $(24hex). 3. Scan the bar codes for 2 and 4 on the inside back cover of this manual. 4. Scan the Store Settings bar code on the inside back cover. 5. Scan the Exit bar code. Insert G1/G2/G3/G4 Character Setting: The QS2500 offer four positions and four characters to insert into the symbol data. Example:

Bar code: “1 2 3 4 5 6”. Output: “1 2 A B 3 4 C D 5 6”.

1. Scan Start Program and Insert G1 Characters Setting bar code below. 2. Use the ASCII code table (see Appendix C on page 64) to find the ASCII value for A (41) and B (42). 3. Scan the hex digit bar codes for 4, 1 and 4, 2 on the inside back cover of this manual.

20

QS2500

Page 25

4. Scan the Store Settings bar code on the inside back cover. 5. Repeat the same procedure for the G2 characters. 6. Scan the Exit bar code. 7. Insert the data group 1–4 position. (page 22.) Start Program $

Option Bar Code

Option None

Prefix 1–22 characters None Suffix

1–22 characters

Alphanumeric Entry 00* 00–ffhex ASCII code 00 00–ffhex ASCII code <cr>*

None Preamble 1–22 characters None Postamble 1–22 characters

00* 00–ffhex ASCII code 00* 00–ffhex ASCII code

None 00*

Insert G1 Characters Setting 1–22 characters

Product Reference Guide

00–ffhex ASCII code

21

Page 26

Option Bar Code

Option

Alphanumeric Entry

None 00*

Insert G2 Characters Setting 1–22 characters

00–ffhex ASCII code

None 00*

Insert G3 Characters Setting 1–22 characters

00–ffhex ASCII code

None 00*

Insert G4 Characters Setting 1–22 characters

00–ffhex ASCII code Exit

Preamble Transmission: The preamble will be appended before the code data. Postamble Transmission: The postamble will be appended after the code data. Insert Data Group 1–4 Position: The QS2500 offers four positions to insert characters into the bar code data. The position default value of “00” indicate no character insertion.

Make sure insertion positions are not greater than the number of bar code characters; otherwise, the data will not be inserted. NOTE Code ID Position: The code ID can be placed before or after the code data.

--

Page 27

Start Program $

Option Bar Code

Preamble Transmission

Postamble Transmission

Insert Data Group 1 Position

Insert Data Group 2 Position

Insert Data Group 3 Position

Insert Data Group 4 Position

Code ID Position

Option

Alphanumeric Entry

Disable

00*

Enable

01

Disable

00*

Enable

01

0–63 (0 = no insertion)

00* 00–63

1–22 characters

00–ffhex ASCII code

0–63 (0 = no insertion)

0–63 (0 = no insertion)

0–63 (0 = no insertion)

00* 00–63

00* 00–63

00* 00–63

Before code data

00*

After code data

01 Exit

Code ID Transmission: Enable this option to transmit the code ID. See page 25.

Code Length Transmission: A number of data digits can be transmitted before the code data. The total length of the bar code is the number of characters of bar code data without truncated leading or ending digits.

Product Reference Guide

23

Page 28

Code Name Transmission: This function is used to show unknown bar code symbologies that include all readable symbologies of the QS2500. The code name will be transmitted before the bar code data to identify the symbology. Case Conversion: You can set the alpha characters to be displayed as either uppercase or lowercase. Order of transmission precedence: Prefix

Code Name

Preamble

Code ID

Code Length

Bar Code Data

Code ID

Postamble

Suffix

Insert Groups or

Option Bar Code

Code ID Transmission

Code Length Transmission

Option Disable

00*

Enable

01

Disable

00*

Enable Disable

Code Name Transmission

Case Conversion (for bar code alpha data only)

Alphanumeric Entry

Enable

01 00* 01

Disable

00*

Uppercase

01

Lowercase

02 Exit