Page 5
Installation Complete the following steps for the appropriate interface.
Keyboard Wedge 1. Turn off the terminal or computer. 2. Disconnect the keyboard cable from the back of the terminal or computer. 3. Connect the QS2500 to the terminal or computer using the appropriate interface cable. 4. Turn the terminal or computer back on.
Wand Emulation 1. Turn off the terminal or computer. 2. Connect the appropriate interface cable to the terminal or computer. 3. Turn the terminal or computer on.
RS-232 1. Turn off the terminal or computer. 2. Connect the interface cable and the external power supply (DC adapter) shipped with your QS2500. If a power-off-terminal (POT) cable is shipped, no external power supply is required. 3. Secure the connector to the serial port on the back of the computer or terminal by tightening the two screws. 4. If required, plug the power supply into the power source. 5. Turn the terminal or computer on.
Product Reference Guide
1
Page 6
86% 1. Plug the USB cable into the terminal or computer.
If the QS2500 does not operate, turn off the terminal or computer immediately and check all connections. If necessary, go through the above steps again. NOTE
,%0 1. Turn off the terminal or computer. 2. Connect the appropriate interface cable to the terminal or computer. 3. Turn the terminal or computer on.
-
Page 7
Programming the QS2500 To program the QS2500, you must scan a series of programming bar codes in the correct order. The inside back cover of this manual contains a table of alphanumeric bar codes needed to program the various options. To program each option: 1. Scan the Start Program bar code above the list of options (see the table below). 2. Enter the option mode by scanning the Option bar code. 3. Find the alphanumeric entry for the option setting you want, and scan the alphanumeric characters located in Appendix E. Auto-detect - the scanner can automatically detect the interface hardware for all interfaces except Wand Emulation. NOTES
IBM interfaces - must be selected individually depending on the port used. Refer to IBM Interface on page 13.
4. Scan the Store Settings bar code in Appendix E. 5. Scan the Exit bar code.
Product Reference Guide
3
Page 8
Table 1. Interface Options Start Program
Option Bar Code
Option
Alphanumeric Entry
Keyboard Wedge
00
RS-232
01
Wand Emulation
02
USB
03
AutoDetect
04
IBM
05
Exit $ $
- An asterisk (*) in the table indicates the default setting.
NOTES
- A software utility, Configurator Express, is also available for programming and configuring the QS2500. Refer to the Readme file on the QS2500 product CD for additional information.
To return all QS2500 option settings to the factory defaults, scan the following two bar codes, in the order shown: Start Program
Default Value Initialization