Page 81

Scan the SET SECOND FIXED LENGTH label.

6.

Set the second fixed label length by scanning the correct digits from this page. The selectable range is from 03 to 50 digits1.

7.

Scan the END label to complete the procedure.

SYMBOLOGY SELECTION

5.

-------- 0 1 ------------------------------------- 2 CODABAR SET FIXED LENGTHS

3 ------------------------------------- 4 5 ------------------------------------- 6 7 ------------------------------------- 8 9 ---------------------------------------------------------------------------- END

1

The scanner will decode up to 50 characters, but the actual length read will vary depending upon bar code size and quality. The IBM POS interface is limited to 32 character labels.

R44-2018

75

Page 82

NOTE MSI/Plessey may not be supported for your scanner. Contact your distributor, PSC Sales or PSC Technical Support for more information. MSI/Plessey Check Digit options include: Check Digit Calculation, calculates the Check Digit to verify the labels contents have been read correctly. If you enable this feature, your bar codes must include a Check Digit. You may also choose to transmit or not transmit the Check Digit. Transmit Check Digit, enables or disables transmission of MSI/ Plessey Check Digit(s). Number of Check Digits, specifies either one or two Check Digits.

SET --------------------------------------------------------- CALCULATE CHECK DIGIT

DON'T CALCULATE CHECK DIGIT MSI/PLESSEY CHECK DIGIT SELECTIONS

SYMBOLOGY SELECTION

MSI/Plessey Check Digit

-------- TRANSMIT CHECK D IGIT

DON'T T RANSMIT CHECK DIGIT

-------- ONE CHECK DIGIT

TWO CHECK DIGITS ----------

----------------------------------------------- END

76

QuickScan™ 1000 Programming Guide

Page 83

With the QuickScan™ 1000 scanner, you now have the option of requiring MSI/ Plessey labels to have one or two fixed length(s). To set fixed length(s) for MSI/Plessey labels: 1.

Identify the fixed length setting(s) you wish to make. Fixed lengths can be set from four to fifteen, including check character(s).

2.

Scan the SET label.

3.

Scan the ENABLE MSI/PLESSEY FIXED label.

4.

Scan the SET FIRST FIXED LENGTH label.

5.

Set the first fixed label length by scanning the correct digits on the following page. If you are setting a length less than ten, you must scan a zero first and then the length digit (e.g., 04, 06, 09). If a second fixed length is not needed, skip to Step 8.

6.

If a second fixed length is desired, scan the SET SECOND FIXED LENGTH label.

7.

Set the second fixed label length by scanning the correct digits on the following page. Remember, if you're setting a length less than ten, you must scan a zero first and then the length digit.

8.

Scan the END label.

MSI/PLESSEY ENABLE FIXED LENGTHS

SET --------------------------------------------------

R44-2018

----- ENABLE MSI/PLESSEY FIXED

DISABLE MSI/PLESSEY FIXED -----

77

SYMBOLOGY SELECTION

MSI/Plessey Fixed Length

Page 84

SYMBOLOGY SELECTION

-------- SET F IRST F IXED L ENGTH SET SECOND FIXED LENGTH -------- NO SECOND F IXED L ENGTH 0 ------------------------------

MSI/PLESSEY SET FIXED LENGTHS

-------- 1 2 ------------------------------------- 3 4 ------------------------------------- 5 6 ------------------------------------- 7 8 ------------------------------------- 9 END -------------------------------------------------

78

QuickScan™ 1000 Programming Guide

Page 85

General Features

Good Read Beeper Settings These labels provide options for the scanner's audible 'beep' signal. Audible Signal, enables/disables the beep upon completion of a good read. NOTE It is strongly recommended that this feature remain enabled, as the good read beep provides the best scanning status feedback to the user. Error tones are always enabled and cannot be disabled.

Power-up Beep, when enabled, beeps upon scanner power-up. Beeper Volume, allows setting of the beeper to NORMAL or HIGH volume. Good Read Beep Duration, can be adjusted to short (100msec), medium (250msec), or long (500msec) durations. When to Beep, may be programmed to announce a 'good read' upon completion of one of the following events: •

Decode of a bar code label

•

Transmission from the scanner to the host

•

CTS activation at the host terminal (RS-232 models ONLY)

R44-2018

79

GENERAL FEATURES

The following section contains the general features that are common to all interfaces. These features allow modification of the scanner's behavior to accomodate user preferences.

Page 86

POWER -UP BEEP BEEPER VOLUME BEEP DURATION

-------- O FF ON ----------------------------------- E NABLE DISABLE ------------------------------ N ORMAL LOUD --------------------------------- S HORT M EDIUM ------------------------------ LONG

WHEN TO BEEP

GENERAL FEATURES

AUDIBLE SIGNAL

SET --------------------------------------------------

AFTER DECODE --------------------- AFTER LABEL X- MISSION AFTER CTS ACTIVATION -------------------------------------------------- END

80

QuickScan™ 1000 Programming Guide

Page 87

Read Verification

GENERAL FEATURES

QuickScan™ 1000 programming has been improved to allow selection of read verification "minimum read" requirements by symbology type, as well as universally. This means that the scanner needn't waste valuable time verifying high-confidence symbologies, while offering the security of multiple read verification on less reliable codes. NOTE The more times the scanner is required to read and compare the bar codes data, the longer it will take to complete a good read cycle.

Universal Read Verification To set read requirements universally (read requirements will be in effect for all symbologies), scan one of the selections below for one, two, three or four reads required before a bar code's data can be transmitted to the host. NOTE DO NOT scan SET or END bar codes when programming these features. Programming mode is automatically entered and exited when one of the four bar codes below are scanned.

UNIVERSAL READ VERIFICATION

Verify 1 Read, all symbologies

Verify 2 Reads, all symbologies

Verify 3 Reads, all symbologies

Verify 4 Reads, all symbologies

R44-2018

81

Page 88

Read Verification by Symbology To set the minimum read requirement for a desired symbology: Scan the SET label.

2.

Scan one symbology label below to select the symbology to be verified.

3.

Scan the label on the following page representing the amount of times you wish a bar code label of that symbology type to be read before transmission to the host.

4.

Repeat steps one through three above until read verification has been selected for all symbologies you desire to be verified.

5.

Scan the END label.

SET --------------------------------------------------------- VERIFY UPC-A READ VERIFICATION SYMBOLOGY TYPE

GENERAL FEATURES

1.

VERIFY UPC-E -------------

-------- VERIFY EAN-8

VERIFY EAN-13 ------------------- VERIFY I NSTORE L ABEL1

VERIFY CODE 39 ------------

1

82

Instore labels are UPC-A bar codes with a number system character of 2 or 4, and EAN-8 and EAN-13 bar codes with a Flag 1 character of 2.

QuickScan™ 1000 Programming Guide

Page 89

-------- VERIFY STANDARD 2 OF 5 GENERAL FEATURES

READ VERIFICATION SYMBOLOGY TYPE

VERIFY I NTERLEAVED 2 OF 5

VERIFY CODABAR -------------

-------- VERIFY C ODE 93

VERIFY CODE 128 ----------

VERIFY READS (APPLIES TO ALL SYMBOLOGIES ABOVE )

-------- VERIFY MSI/P LESSEY

ONE R EAD -------------------

-------- TWO READS

THREE READS ----------------

-------- FOUR R EADS

END -------------------------------------------------

R44-2018

83

Page 90

Debug Mode When enabled, this mode will cause any product labels that are read to be discarded with no attempt made to transmit them to a host. Any host scanning control will also be disabled while this option is in effect. This mode may be enabled in conjunction with any of the defined host interfaces. All other programmable options that are set for that interface will remain in effect while in debug mode.

DEBUG MODE

GENERAL FEATURES

SET --------------------------------------------------

-------- E NABLE

DISABLE -----------------------

----------------------------------------------- END

84

QuickScan™ 1000 Programming Guide