Page 71

SYMBOLOGY SELECTION

SET --------------------------------------------------------- SET FIRST F IXED L ENGTH

INTERLEAVED 2 OF 5 F IXED AND MINIMUM LABEL LENGTHS

SET SECOND FIXED LENGTH -------- NO SECOND F IXED L ENGTH SET MINIMUM LABEL LENGTH -------- 0 1 ------------------------------------- 2 3 ------------------------------------- 4 6 ------------------------------------- 8 END ------------------------------------------------R44-2018

65

Page 72

SYMBOLOGY SELECTION

Standard 2 of 5 The Standard 2 of 5 symbology has the following programmable features: Check Digit, calculates the Check Digit to verify that the Check Digit contained in the bar code label is correct. If you enable this feature, your bar codes must contain a Check Digit. You may also choose to transmit or not transmit the Check Digit independent of whether the Check Digit is calculated by the scanner. The Transmit Check Digit will have no effect unless the Compute Check Digit feature is enabled. If you choose Don’t Compute Check Digit, the scanner sends the Check Digit encoded in the bar code without verifying its accuracy. If you choose both Compute Check Digit and Don't Transmit Check Digit, the scanner will remove the Check Digit's contents before sending the bar code data to the host. The Transmit Check Digit option has no effect unless the Compute Check Digit option is enabled. Label Format, provides the selection between fixed or variable length labels. If your application has labels with specific fixed lengths, we recommend selecting fixed lengths to improve read rate and avoid short reads. You can select any valid number of digits for reading specific length labels only. Read the following details for specific Standard 2 of 5 limits.

Standard 2 of 5 Label Lengths Standard 2 of 5 Minimum Label Length, sets the minimum label length required for Standard 2/5 labels (including the check character). This feature is provided to ignore small label segments, reducing the possibility that a portion of a good label is incorrectly seen as an entire label. Variable Length, if you select variable length, the scanner will recognize labels with a number of digits between 04 and 50 digits1. Note: The Variable Length Label feature must be DISABLED in order that Fixed Label Length features can work. Fixed Length, if you select fixed length, there are three labels for programming your scanner to read either one or two fixed lengths. The labels are: •

Set First Fixed Length, use this label to instruct the scanner that the next two programming labels you scan will define the first fixed label length. This setting can be any number of digits between 04 and 50 digits1 (including check character).

1

The scanner will decode up to 50 characters, but the actual length read will vary depending upon bar code size and quality. The IBM POS interface is limited to 32 character labels.

66

QuickScan™ 1000 Programming Guide

Page 73

Set Second Fixed Length, use this label to instruct the scanner that the next two programming labels you scan will define the second fixed label length. Again, this setting can be any number of digits between 04 and 50 digits1 (including check character).

•

No Second Fixed Length, scan this label after setting the first fixed length to instruct the scanner to recognize only the label length chosen as the first fixed length.

Check Digit and Variable Length Label Selections These programming labels determine whether you compute and send the check digit contents. If you want to set the scanner to read only fixed length labels, follow the procedures on the pages immediately following.

SET --------------------------------------------------

CHECK DIGIT

-------- DON'T COMPUTE COMPUTE ---------------------------- D ON'T TRANSMIT

VARIBLE LENGTH LABELS

T RANSMIT ---------------------------- ENABLE DISABLE --------------------------------------------------------------------- END 1

The scanner will decode up to 50 characters, but the actual length read will vary depending upon bar code size and quality. The IBM POS interface is limited to 32 character labels.

R44-2018

67

SYMBOLOGY SELECTION

•

Page 74

SYMBOLOGY SELECTION

Setting Standard 2 of 5 Fixed and Minimum Label Lengths All interfaces that are shipped with the standard factory configuration are set to read variable length labels. If you switch from variable to fixed length labels, the default fixed label lengths are 14 digits and 8 digits. Follow the steps below to change these defaults. Set Fixed 1. Identify the fixed length settings you want to make. 2.

Scan the SET label.

3.

Scan the ENABLE FIRST FIXED bar code.

Setting Fixed Lengths If you are setting a length less than ten, you must scan a zero first and then the length digit ( 04, 07, 08). 4. Set the first fixed label length by scanning the correct digits from the next two pages. If you need to set a second fixed length, continue with step five. If you do not need to set a second fixed length scan the NO SECOND FIXED LENGTH below and skip to step seven. 5.

Scan the SET SECOND FIXED label.

6.

Set the second fixed label length by scanning the correct digits from this page.

7.

Scan the END label to complete the procedure.

Setting Minimum Label Length 1. Identify the minimum length setting you want to make. The selectable range is 01 to 50 characters1. 2.

Scan the SET label.

3.

Scan the SET MINIMUM LABEL LENGTH bar code.

If you are setting a length less than ten, you must scan a zero first and then the length digit ( 04, 07, 08). 4. Set the minimum label length by scanning the correct digits from the next two pages.

68

5.

Scan the END label.

1

The scanner will decode up to 50 characters, but the actual length read will vary depending upon bar code size and quality. The IBM POS interface is limited to 32 character labels.

QuickScan™ 1000 Programming Guide

Page 75

SYMBOLOGY SELECTION

SET --------------------------------------------------------- SET FIRST F IXED L ENGTH

SET SECOND FIXED LENGTH

STANDARD 2 OF 5 FIXED AND MINIMUM LABEL LENGTHS

-------- NO SECOND F IXED L ENGTH

SET MINIMUM LABEL LENGTH -------- 0

1 ------------------------------

-------- 2

3 ------------------------------

-------- 4

5 ------------------------------

-------- 6

R44-2018

69

Page 76

STANDARD 2 OF 5 FIXED AND MINIMUM LABEL L ENGTHS

SYMBOLOGY SELECTION

-------- 7

8 ------------------------------

-------- 9

END -------------------------------------------------

70

QuickScan™ 1000 Programming Guide

Page 77

The Codabar symbology has the following programmable features: Check Digit, calculates the Check Digit to verify the label's contents have been read correctly. If you enable this feature, your bar codes must include a Check Digit. You may also choose to transmit or not transmit the Check Digit. Start/Stop Characters, you can choose either Send or Don't Send depending on your host's interface requirement. Start/Stop Format, if you need to send the Start/Stop characters, there are four standard format options that you can select from; ABCD/ TN*E, ABCD/ABCD, abcd/tn*e, or abcd/abcd. This setting must match your system requirements. If you select one of these options, it determines how the ASCII characters A, B, C, D that are used for Start/Stop characters, will be translated before being sent to the host. Start/Stop Match, the requirement that the Start and Stop characters must match (be identical) can be enabled or disabled. Label Format, provides the selection between fixed or variable length labels. If your application has labels with specific fixed length, we recommend selecting fixed lengths to improve read rate. If you select variable length, the scanner will recognize labels with between 03 and 47 digits1 (not including the optional check digit). Set First Fixed Length, if you select fixed length, use this feature to set a first fixed label length to a setting between 03 and 50 * digits. Set Second Fixed Length, if you select fixed length, use this feature to set a second fixed label length to a setting between 03 and 50 digits1. No Second Fixed Length, scan this label after setting the first fixed length to instruct the scanner to recognize only the label length chosen as the first label length. Gap Check, allows the scanner to combine two label halves printed in close proximity to each other that may have been printed at different times and perhaps different locations.

1

The scanner will decode up to 50 characters, but the actual length read will vary depending upon bar code size and quality. The IBM POS interface is limited to 32 character labels.

R44-2018

71

SYMBOLOGY SELECTION

Codabar Options

Page 78

These programming labels determine whether you compute and send the check digit contents and enables variable length. If you want to set the scanner to read only fixed length labels, follow the procedures on the following pages.

SET --------------------------------------------------

CHECK DIGIT

-------- D ON'T COMPUTE

COMPUTE ---------------------

-------- D ON'T TRANSMIT

VARIABLE LENGTH LABELS

TRANSMIT ---------------------

-------- E NABLE

DISABLE -----------------------

GAP CHECK

SYMBOLOGY SELECTION

Codabar Check Digit & Variable Length

-------- E NABLE

DISABLE -----------------------

----------------------------------------------- END

72

QuickScan™ 1000 Programming Guide

Page 79

These bar codes allow you to set the Start/Stop character format and transmission. Refer to your host user's manual to identify your system requirements, then use these labels to selectwhichcharactersaretransmitted.

SET --------------------------------------------------------- M ATCH NOT REQUIRED

START /STOP FORMAT & TRANSMISSION SPECIFICATIONS

MATCH REQUIRED ------------

-------- DON'T TRANSMIT TRANSMIT1 --------------------

-------- FORMAT = ABCD/TN*E

FORMAT = abcd/tn*e -----

-------- FORMAT = ABCD/ABCD

FORMAT = abcd/abcd ----

----------------------------------------------- END 1

Choosing Transmit Start/Stop characters requires selecting one of these four data format selections: ABCD/TN*E, abcd, tn*e, ABCD/ABCD, or abcd/abcd. Refer to Appendix A, Standard Factory Settings, to identify the default setting for your scanner's interface type.

R44-2018

73

SYMBOLOGY SELECTION

Codabar Start/Stop Character

Page 80

Most scanners shipped from the factory are set to read variable length labels for Codabar. If you switch from variable to fixed length labels, the factory set fixed label lengths are 14 and 08. Follow the steps below to change these defaults. Enable Fixed 1. Identify the fixed length settings you want to make. 2.

Scan the SET label.

3.

Scan the SET FIRST FIXED LENGTH label.

Setting Lengths If you are setting a length less than ten, you must scan a zero first and then the length digit (02, ...09). 4.

Set the first fixed length label by scanning the correct digits from the next page. The selectable range is from 03 to 50 digits1. If you need to set a second fixed length, continue with step five. If you do not need to set a second fixed length, scan the NO SECOND FIXED LENGTH label below and skip to step seven.

SET --------------------------------------------------------- SET FIRST F IXED L ENGTH CODABAR

SYMBOLOGY SELECTION

Codabar Fixed Length

SET SECOND FIXED LENGTH

-------- NO SECOND F IXED L ENGTH

1

74

The scanner will decode up to 50 characters, but the actual length read will vary depending upon bar code size and quality. The IBM POS interface is limited to 32 character labels.

QuickScan™ 1000 Programming Guide