Page 31

Country Mode The following country/languages can be selected for the QuickScan 1000™ scanner when configured for I/F Type E only: • • • •

USA Belgium Britain Denmark

• • • •

France Germany Italy Norway

• Portugal • Japanese 106-Key • Spain • Sweden • Switzerland

SET ------------------------------------------------------------- USA

B ELGIUM ----------------------

DENMARK -------------------------------- F RANCE

KEYBOARD WEDGE INTERFACE

COUNTRY MODE

------------ BRITAIN

GERMANY --------------------------

I TALY

NORWAY --------------------------------- P ORTUGAL

R44-2018

25

Page 32

Country Mode, continued

COUNTRY MODE

------------ SPAIN S WEDEN ----------------------

------------ S WITZERLAND JAPANESE 106-KEY ---------

----------------------------------------------- END

KEYBOARD WEDGE INTERFACE

26

QuickScan™ 1000 Programming Guide

Page 33

Intercharacter Delay Intercharacter Delay refers to the pause, if any, between each character before it is sent to the host. This time delay is used to control the flow of data from the scanner, but it should not be required for most applications. Use these labels to select the desired Intercharacter Delay.

SET ------------------------------------------------------------- NONE 5 MILLISECONDS ------------------------- 10 MILLISECONDS

------------ 20 MILLISECONDS 25 MILLISECONDS ----------------------- 30 MILLISECONDS

KEYBOARD WEDGE INTERFACE

I NTERCHARACTER DELAY

15 MILLISECONDS ------------

35 MILLISECONDS ----------------------- 40 MILLISECONDS 45 MILLISECONDS ------------

R44-2018

27

Page 34

------------ 50 MILLISECONDS

55 MILLISECONDS ------------

------------ 60 MILLISECONDS

I NTERCHARACTER DELAY

65 MILLISECONDS ------------

------------ 70 MILLISECONDS

75 MILLISECONDS ------------

------------ 80 MILLISECONDS

85 MILLISECONDS ------------

KEYBOARD WEDGE INTERFACE

------------ 90 MILLISECONDS

95 MILLISECONDS ------------

------------ 99 MILLISECONDS

END -------------------------------------------------

28

QuickScan™ 1000 Programming Guide

Page 35

PSC OCIA1 Interface Selection Scan this label to enable the PSC OCIA interface.

NCR OCIA Eight Bit (short format) Interface Selection Scan this label to enable the NCR OCIA (short format) interface.

NCR OCIA Nine Bit (long format) Interface Selection Scan this label to enable the NCR OCIA Nine Bit (long format) interface.

SNI OCIA Interface Selection

KEYBOARD WEDGE INTERFACE

Scan this label to enable the SNI OCIA interface.

1

NOTE: In previous publications, this interface was termed, "SP OCIA".

R44-2018

29

Page 36

OCIA Options Use these labels to change the settings as desired. The following brief descriptions explain each selection. Beep if Not on File, when enabled requires the scanner to beep when a label is scanned that is not on file. Host Commands, when enabled allows the scanner to accept commands directly from the host. Intercharacter Delay, refers to a pause, if any, between each character before being sent to the host. This time delay is used to control the flow of data from the scanner, but it should not be required for most applications. When enabled, OCIA intercharacter delay is set at 70µs.

BEEP IF NOT ON FILE KEYBOARD WEDGE INTERFACE

E NABLE -----------------------------

HOST COMMANDS

----------------------------------------------

E NABLE -----------------------------

I NTERCHARACTER DELAY

SET

E NABLE -----------------------------

END

30

DISABLE -----------------------------

DISABLE -----------------------------

DISABLE --------------------------------------------------------------------------

QuickScan™ 1000 Programming Guide

Page 37

Label Transmit Format Configuration Items (RS-232 and Keyboard Wedge Interfaces Only) If you need to send information in addition to label data, the scanner can be configured to transmit prefixes and/or suffixes as well as symbology specific identifier characters (Label I.D.).

Prefix & Suffix As the examples below show, none, one or two symbology specific ASCII characters can be added to the beginning of label in addition to multiple prefix and suffix characters.

NOTE Using this feature requires a thorough understanding of your specific system requirements.

The options available using this feature are: symbology specific (0 - 2) characters + label data PP + label data

• non-symbology specific characters (1-2) as a prefix + label data CpCp + label data

• label data + non-symbology specific characters (0-2) as a suffix label data + CsCs

• non-symbology specific characters (1-2) as a prefix + symbology specific characters (0-2) + label data CpCp + PP + label data

• symbology specific characters (0-2) + label data + non-symbology specific characters (1-2) as a suffix PP + label data + CsCs

R44-2018

LABEL TRANSMIT FORMAT CONFIG

•

31

Page 38

• non-symbology specific characters (1-2) as a prefix + label data + nonsymbology specific characters (1-2) as a suffix CpCp + label data + CsCs

• non-symbology specific characters (1-2) as a prefix + symbology specific characters (0-2) + label data + non-symbology specific characters (1-2) as a suffix CpCp + PP + label data + CsCs

• non-symbology specific characters (1-2) as a prefix + label data + symbology specific characters + non-symbology specific characters used as suffixes. CpCp + label data + PP + CsCs

LABEL TRANSMIT FORMAT CONFIG

PP = symbology specific characters (Label I.D.) CpCp = non-symbology specific ASCII characters used as prefixes CsCs = non-symbology specific ASCII characters used as suffixes

32

QuickScan™ 1000 Programming Guide

Page 39

Setting Non-Symbology Specific Prefix(es) These characters will be added to the standard label format when your host system has specific and unique requirements for information added to the barcode label data before it is sent to the host. Identify your specific system requirements before adding or modifying these settings, then... 1.

Look at the ASCII chart shown on page 38 and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as prefixes. For example, if you are going to send two prefix characters as 'STX' (start transmit) and 'SP' (Space). The ASCII chart shows that 'STX' equals 02hex and 'SP' equals 20hex.

2.

Scan the SET label.

3.

Scan the SET PREFIX label on this page.

4.

Scan the digits that correspond to the Hex Values. For the example in step four, scan 0, 2, 2, 0.

NOTE If you make a mistake, or lose your place while setting this option, scan the END label to exit Programming Mode. The scanner will sound an error tone (six rapid beeps) to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode. 5.

Scan END. You have added a two character prefix to all label data, regardless of label symbology, that will be added to the label data before it is sent to the host.

SET --------------------------------------------------

LABEL TRANSMIT FORMAT CONFIG

-------- SET PREFIX

Go to the second page following this and scan the appropriate characters before scanning the END label to exit programming session.

R44-2018

33

Page 40

Setting Non-Symbology Specific Suffix(es) These characters will be added to the standard label format when your system has specific and unique requirements for information added to the barcode label data before it is sent to the host. Suffix characters follow the label data. Identify your specific system requirements before adding or modifying these settings, then... 1.

Look at the ASCII chart shown on page 38 and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as suffixes. For example, if you are going to send two suffix characters as 'BEL' (sound host tone) and 'ETX' (end transmission). The ASCII chart shows that 'BEL' equals 07 hex and 'ETX' equals 03 hex.

2.

Scan the SET label.

3.

Scan the SET SUFFIX label on this page.

4.

Scan the digits that correspond to the Hex Values. For the example in step five, scan 0, 7, 0, 3.

NOTE If you make a mistake, or lose your place while setting this option, scan the END label to exit Programming Mode. The scanner will sound an error tone (six rapid beeps) to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode. 5.

Scan END. You have added a two character suffix to all label data, regardless of label symbology, that will be added to the label data before it is sent to the host.

SET -------------------------------------------------LABEL TRANSMIT FORMAT CONFIG

-------- SET SUFFIX Go to the next two pages and scan the appropriate characters before scanning the END label to exit programming session.

34

QuickScan™ 1000 Programming Guide