Page 21
Baud Rate Use the bar codes on this page to select the communications Baud Rate. Only one Baud Rate selection may be active at any one time. The last Baud Rate label you scan during a programming session will be the setting that is stored when you scan the END label.
SET --------------------------------------------------------------- BAUD = 1200
BAUD RATE
BAUD = 2400 ---------------------------- BAUD = 4800 BAUD = 9600 ---------------
RS-232 INTERFACE
-------------- BAUD = 19200 BAUD = 38400 ----------------------------------------------------------- END Data Format Table There are many possible data format configurations for an RS-232 interface. Check your host system manual to find out your system's communications requirements. This table shows the acceptable format options. Data Bits Seven Seven Seven Eight Eight Eight R44-2018
Start Bit 1 1 1 1 1 1
Parity Bit(s) 0 1 1 0 0 1
Stop Bit(s) 2 1 2 1 2 1
15
Page 22
Data Format Settings The bar codes on this page can be used to select the data format configuration needed to communicate with your system.
SET --------------------------------------------------------------- NONE
PARITY
EVEN --------------------------
-------------- O DD
MARK -------------------------
--------------- S PACE
STOP BITS
-------------- T WO
SEVEN BITS -----------------DATA BITS
RS-232 INTERFACE
O NE ---------------------------
-------------- EIGHT BITS
END -------------------------------------------------
16
QuickScan™ 1000 Programming Guide
Page 23
Handshaking Review your system documentation to identify handshaking requirements, and use these labels to change the settings if required. The following brief descriptions explain eachselection.
Hardware Control CTS/RTS Flow Control, is hardware handshaking. The scanner activates the RTS (Ready to Send) line when it is ready to send data to the host. The scanner waits for an active Clear to Send (CTS) signal from the host before transmitting data. If hardware control is disabled, CTS/RTS communication will not take place. If the host deactivates the CTS line during data transmission, the host will receive additional characters for no more than 2msec1.
CTS/RTS Flow Control Data
Label Transmission
Disabled
Xmission
Label Transmission
Active
CTS
CTS Scan Control, is also a hardware control. When scan control is enabled, label transmission is disabled until CTS is asserted and de-asserted.
CTS Scan Control Data
Label 1
Label 1
Will not scan again until toggle Label 2
Disabled until Assert
CTS
1
De-assert
Varies slightly depending upon baud rate selected.
R44-2018
17
RS-232 INTERFACE
Inactive
Page 24
Software Control XON/XOFF, this is software handshaking that allows the host to control data transmission. If the host sends an XOFF command to the scanner, the scanner will not send the bar code data until it receives an XON command from the host. If the host sends the XOFF command during data transmission, the host will receive additional characters for no more than 2msec1.
NOTE Hardware/software controls are mutually exclusive. Enable only one of these features at a time, as enabling multiple controls can produce unpredictable results.
SET --------------------------------------------------
SOFTWRE C ONTROL
RS-232 INTERFACE
HARDWARE CONTROL
--------------- DISABLE HARDWARE C ONTROL
ENABLE CTS/RTS FLOW CONTROL
--------------- ENABLE CTS SCAN CONTROL
ENABLE XON/ X OFF ---------
-------------- D ISABLE XON/XOFF
END -------------------------------------------------
1
18
Varies slightly depending upon baud rate selected.
QuickScan™ 1000 Programming Guide
Page 25
Intercharacter Delay Intercharacter Delay refers to the pause, if any, between each character before it is sent to the host. This time delay is used to control the flow of data from the scanner, but it should not be required for most applications. Use these labels to select the desired Intercharacter Delay.
SET --------------------------------------------------------------- N ONE
10 MILLISECONDS ------------
-------------- 20 MILLISECONDS
-------------- 40 MILLISECONDS
RS-232 INTERFACE
INTERCHARACTER DELAY
30 MILLISECONDS ------------
50 MILLISECONDS ------------
-------------- 60 MILLISECONDS
70 MILLISECONDS ------------
-------------- 80 MILLISECONDS
R44-2018
19
Page 26
I NTERCHARACTER DELAY
Intercharacter Delay - continued
90 MILLISECONDS ------------
-------------- 100 MILLISECONDS
END -------------------------------------------------
RS-232 INTERFACE
20
QuickScan™ 1000 Programming Guide
Page 27
This section contains the following PC Keyboard Wedge communication parameters in the order listed:
Keyboard Wedge Communication Parameters •
Interface Selection
•
Connect to Laptop
•
Caps lock Settings
•
Country modes
•
Intercharacter Delay
Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other settings.
NOTE If the transmission parameters are configured such that a label results in no actual data to send, the label will be accepted, beeped, and no data transmitted.
PC Keyboard Wedge Interface Selection The scanner supports ten1 PC Keyboard Wedge interfaces. The table below defines the different interface selections. I/F Type
PCs Supported PC/XT w/Alternate Keyboard Encoding AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Keyboard Encoding PS/2 25 and 30 w/Alternate Keyboard Encoding PC/XT w/Standard Key Encoding AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding PS/2 25 and 30 w/Standard Key Encoding IBM 3xxx w/122 keyboard IBM 3xxx w/102 keyboard PS/55 5530T w/104 keyboard NEC9801keyboard
KEYBOARD WEDGE INTERFACE
A B C D E F G H I J
NOTE We recommend that you disconnect power before plugging/ unplugging cables to avoid any possibility of equipment damage.
R44-2018
21
Page 28
PC Keyboard Wedge Interface Selection - continued The scanner supports ten1 PC Keyboard Wedge interfaces. The table below defines the different interface selections.
SET ---------------------------------------------------- A
I NTERFACE (I/F) TYPE (SEE TABLE ON PREVIOUS PAGE)
B ---------------------------------------
C
-----------
E
D -----------------------------
F ----------------------------------------- G
KEYBOARD WEDGE INTERFACE
H ---------------------------------------- I J ---------------------------------------------------------------------------- END 1
22
Keyboard Wedge interfaces G through J are only supported by the QuickScan 1000 scanner.
QuickScan™ 1000 Programming Guide
Page 29
PC Keyboard Wedge – Connect to a Laptop/ No Keyboard Attached If no keyboard is attached, the scanner must provide the acknowledge signal to the PC. In this case, enable the "Laptop/No External Keyboard" mode. If a keyboard is attached, enable "Keyboard Attached". Laptop (integrated keyboard), scan the "Laptop/No External Keyboard" label below when the scanner is connected to a laptop computer or when the scanner is operated with no external keyboard attached. PC (external keyboard), if you move the scanner to a standard PC, change the setting to "Keyboard Attached". Send Control Characters, when this feature is disabled, all ASCII characters except NUL (00h) are transmitted. Enabling this feature limits transmission of ASCII characters to the following: •
Only ASCII characters between 20h..127h, plus… - Carriage Return (CR=0Dh) - BackSpace (BS=08h) - Right Tab (HT=09h) - Left Tab (0Bh) - Esc (1Bh)
LAPTOP/N O EXTERNAL KEYBOARD KEYBOARD WEDGE INTERFACE
SEND CONTROL CHARACTERS
CONNECT TO LAPTOP OR PC
SET --------------------------------------------------
KEYBOARD ATTACHED --------
------------ ENABLE
DISABLE -----------------------
----------------------------------------------- END R44-2018
23
Page 30
Caps Lock Three caps lock settings are available for the QuickScan 1000™ scanner. These are: •
Caps Lock Off, to send character data (to the host)in normal format.
•
Caps Lock On, to send character data (to the host) in reverse case: (a…z) = (A…Z) (A…Z) = (a…z) Use this feature if your caps lock is on.
•
Caps Lock = Shift-Lock, to send character data (to the host) in shifted case. Use this feature if your shift lock is on. For use with interface type G (122-keyboard) ONLY.
CAPS LOCK OPTIONS
SET ------------------------------------------------------------- CAPS LOCK OFF
CAPS LOCK ON --------------
------------ CAPS LOCK = S HIFT-LOCK
KEYBOARD WEDGE INTERFACE
END
24
--------------------------------
QuickScan™ 1000 Programming Guide