Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 13

Falcon PT40 Product Reference Guide, pages 91 to 100

Pages 91 to 100 of 122

The original document is the PDF (6.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC PT40 and Datalogic PT40

Page 91

2340.book Page 11 Wednesday, January 29, 2003 12:50 PM

Other Controls

GOOD-READ TONE

Low

Medium Low

*$+$-B800EE* Medium High *$+$-B805EE* *$+$-B802EE*

High

*$+$-B807EE*

GOOD-READ BEEPS

1

*$+$-B901EE*

3

*$+$-B903EE*

2

*$+$-B902EE*

4

*$+$-B904EE*

GOOD-READ TONE DURATION (in seconds)

0.07

*$+$-BA01EE*

0.22

*$+$-BA03EE*

0.14

*$+$-BA00EE*

0.45

*$+$-BA02EE*

KEYPAD TIMEOUT (Intercharacter Delay in seconds)

Off

*$+$-E400EE*

2 Sec

*$+$-E408EE*

1/4 Sec

*$+$-E401EE*

4 Sec

*$+$-E416EE*

1/2 Sec

*$+$-E402EE*

8 Sec

*$+$-E432EE*

3/4 Sec

*$+$-E403EE*

16 Sec

*$+$-E464EE*

Product Reference Guide

D-11

Page 92

2340.book Page 12 Wednesday, January 29, 2003 12:50 PM

Configuring with Bar Codes

1 Sec

*$+$-E404EE*

24 3/4 Sec

*$+$-E499EE*

Off

*$+$-DD0EE*

*%-*

Set Date

*%.*

*$+$-D80EE*

24-Hour

*$+$-D81EE*

International

*$+$-D91EE*

KEYBOARD CLICK

*$+$-DD1EE*

On

Clock and Calendar TIME / DATE FORMAT

Set Time TIME FORMAT

12-Hour

DATE FORMAT

U.S.

*$+$-D90EE*

Serial Parameters HOST SELECT (no default)

AT, PS/2, or compatible

*$+$-C011EE* IBM terminal *$+$-C015EE*

BAUD RATE

300

D-12

*$+$-C100EE*

1200

*$+$-C102EE* Falcon® PT40

Page 93

2340.book Page 13 Wednesday, January 29, 2003 12:50 PM

Serial Parameters

600

*$+$-C101EE*

2400

*$+$-C103EE*

4800

*$+$-C104EE*

38,400

*$+$-C107EE*

9600

*$+$-C105EE*

76,800

*$+$-C108EE*

19,200

*$+$-C106EE* *$+$-C207EE*

8

*$+$-C208EE*

None

*$+$-C300EE*

Even

*$+$-C304EE*

Odd

*$+$-C303EE* 2

*$+$-C402EE*

*$+$-C51EE*

Off

*$+$-C50EE*

*$+$-C600EE*

Add LF

*$+$-C602EE*

DATA BITS

7 PARITY

STOP BITS

1

*$+$-C401EE*

ENABLE XON/OFF

On LINEFEED

None

Product Reference Guide

D-13

Page 94

2340.book Page 14 Wednesday, January 29, 2003 12:50 PM

Configuring with Bar Codes

Strip LF

*$+$-C601EE*

PROTOCOL

EOR only

*$+$-CA00EE* Xmodem *$+$-CA02EE* *$+$-CA01EE*

CR with checksum and ACK/NAK response TIMEOUT (in 100-millisecond units)

0

*$+$-CD00EE*

50

*$+$-CD50EE*

10

*$+$-CD10EE*

75

*$+$-CD75EE*

25

*$+$-CD25EE*

99

*$+$-CD99EE*

D-14

Falcon® PT40

Page 95

2340.book Page 1 Wednesday, January 29, 2003 12:50 PM

Appendix E Programming Parameters Overview The application PALPRO40 loaded some default parameter settings. (Refer to Table E-2 on page E-3.) These settings work for most applications. This appendix provides specifics on all programmable parameter settings for the PT40. •

Table E-1 on page E-2, lists programmable settings and parameter terms.

•

Table E-2 on page E-3, lists default parameters and programming IDs for predefined defaults. These settings work for most applications.

•

Table E-4 on page E-7 lists save-and-exit settings.

•

Table E-6 on page E-9 provides Code Parameters, ID#s, Type, On/Off, Value, Strings, Immediate, and Acceptable Input.

•

Table E-9 on page E-13 provides Code Parameters for serial communications, ID#s, Type, On/Off, Value, Strings, Immediate, and Acceptable Input.

To reset or change the settings on your PT40, you can: •

Scan the bar codes in Table E-2 on page E-3, Table E-3 on page E-4, or Configuring with Bar Codes on page D-1.

•

Create custom bar codes for specific settings (refer to Guidelines for Creating Programming Bar Codes starting on page E-5).

•

Download new programs to the PT40 from Windows (refer to Downloading Applications with PPGXFER starting on page 3-8)

•

Refer to Serial Parameters on page E-12.

Product Reference Guide

E-1

Page 96

2340.book Page 2 Wednesday, January 29, 2003 12:50 PM

Programming Parameters

For information about using PAL, including installation instructions refer toUsing PALPRO40 to Collect Data starting on page 2-7, or to the Portable Applications Library (PAL) User’s Guide, available at www.pscnet.com from the Product Manuals link. For an overview of using PPG to program the PT40, refer to PT Program Generator (PPG) on page 1-10. For complete information refer to the PT Program Generator (PPG) User’s Manual, available at www.pscnet.com from the Product Manuals link. The human readable portion of the barcode symbol, as shown in this manual, is optional and not required for scanning purposes.

Table E-1. Programmable Settings and Parameter Terms Settings

E-2

Description

Code Parameter

The “human” name for programming options.

ID#

The “PT40” name for programming options. For example, to set a Code 39 minimum label length, enter 01 when programming the PT40. Programming ID numbers given in this appendix can be used with all programming methods.

Type

Indicates the kind of setting to use for each code parameter:

On/Off

A toggle. 1 turns the parameter on, and 0 turns it off.

Value

Requires a two-character entry (e.g., 02 for two beeps after each good read, or 05 for a length of five).

String

Uses one or more ASCII characters, followed by // to indicate the end of the string.

Immediate

Takes effect as soon as the ID number is entered.

Acceptable Input

Gives the settings or range of settings that you can use for each code parameter.

Predefined Defaults

Tells how the parameter is set when you select predefined default D0, D1, or D2 (refer to Table E-2).

Falcon® PT40

Page 97

2340.book Page 3 Wednesday, January 29, 2003 12:50 PM

Using Bar Codes

Using Bar Codes To program the PT40, scan Code 39 bar codes that contain the desired parameters and settings. This section provides several programming bar codes. Custom bar codes can be made using any bar code printing software that supports Code 39.

Using Predefined Defaults The PT40 has the following four sets of parameter defaults. These parameters can be used during trouble-shooting, initialization, or setup. Reset the PT40 to a predefined default set by scanning one of the following bar codes: Table E-2. Predefined Defaults for the PT40 Predefined Defaults Default Name

Type

Bar Code

Description

*$+$-D0EE*

Turns every ON/OFF parameter OFF and sets all minimum and maximum lengths to zero. Turns every ON/OFF parameter ON, sets all minimum lengths as low as possible, and sets all maximum lengths as high as possible.

Predefined Default 0 (D0)

Immediate

Predefined Default 1 (D1)

Immediate

*$+$-D1EE*

Predefined Default 2 (D2)

Immediate

*$+$-D2EE* This default set will work for most applications.

Immediate

Restores the default serial communications settings. Refer to Table E-7 on page E-12 for the default settings.

Serial Default

Default set installed on the PT40 at the factory.

*$+$-C8EE*

Product Reference Guide

E-3

Page 98

2340.book Page 4 Wednesday, January 29, 2003 12:50 PM

Programming Parameters

Alternate Parameters for the Falcon PT40 Enter these commands by scanning the bar codes with the PT40’s laser or through the PC’s serial port. With PT Program Generator (PPG), you can embed these codes in a PPG application. The Falcon PT40 recognizes the following bar code commands at all times: Table E-3. Scannable Bar Codes of Alternate Settings for the PT40 Scannable Bar Codes of Alternate Settings for the PT40 Setting Name

Bar Code

Clear Mode

*--* Has the same effect as the

Character Clear Mode

*-+*

High Beep Mode

*.+* Sounds a high beep on the PT40.

Low Beep Mode

*.-* Sounds a low beep on the PT40.

Receive File Mode

*/.* Prepares the PT40 to accept a program.

Retrieve Data Mode

Reset Mode CAUTION

E-4

*$$*

Description <CLR> key

Has the same effect as the <CLR> key for the last character entered.

Retrieves data if the application program stops execution and gives the PROGRAM FAILED message. Connect the PT40 to the PC and start the communications program on the PC, then scan this bar code. The data will transmit, one file at a time.

*+.* Clears all memory and resets the PT40. Falcon® PT40

Page 99

2340.book Page 5 Wednesday, January 29, 2003 12:50 PM

Using Bar Codes

Guidelines for Creating Programming Bar Codes Keep the following in mind when creating bar codes for programming the PT40: •

Create custom programming bar codes using the extended (full ASCII) Code 39 character set.)

•

The first and last character of each bar code must be an asterisk (*), the start and stop character for Code 39.

•

The first asterisk of the programming bar code must be followed immediately by the characters $+$-.

•

The programming bar code must end with EE followed by the last asterisk. The PT40 will treat multiple bar codes of programming information as one entry as long as *$+$- appears at the beginning of the first bar code and EE* does not appear until the end of the last bar code.

Scan the following bar code to enable Code 39 scanning and set the maximum length for Code 39 to 35 characters: Enable Code 39; set max length to 35 characters

*$+$-0010235EE*

Like all Code 39 bar codes, this sample starts and ends with an asterisk (*). $+$- starts programming mode. 00 is the ID number for the parameter that enables Code 39, and 1 turns it on. 02 specifies the Code 39 maximumlength parameter, and 35 sets it to 35 characters per label. EE saves the new settings and exits programming mode.

Using Multiple Bar Codes You can create multiple bar codes to program the PT40. After making the settings in the first bar code (which must begin with *$+$-), the PT40 waits for additional programming bar code entry if the first bar code does not include EE*. You can scan the single bar code above or the following two bar codes to achieve the same results:

*$+$-001* Product Reference Guide

*0235EE* E-5

Page 100

2340.book Page 6 Wednesday, January 29, 2003 12:50 PM

Programming Parameters

Commands cannot be split between two or more bar codes. It is not possible to have a parameter ID number at the end of one bar code and its setting or string at the beginning of the next.

Programming Parameters For a description of serial parameters, refer to Table E-8 on page E-12. For a complete list of parameters and defaults, refer to Programming Parameters on page E-1.

Setting the Hour Format, Time, and Date Use the PT40’s keyboard to enter the time and date in the current format.

Time Turn on parameter ID value D8 to set the PT40's real-time clock display to 24-hour (military-style) format. When this parameter is set to Off, the time is displayed in 12-hour format. The default time display is 24-hour format. Use the 12- and 24-hour bar codes to change the format. To set the time on the PT40’s clock, scan the Time bar code. Time

*%-*

Date Turn on parameter ID value D9 to set the PT40’s date display to international format (day/month/year) or off to set it to U.S. format (month/day/year). The default format is U.S. Format. To set the date in the PT40, scan the Date bar code. Use the International Format bar codes to change the format.Refer to Clock and Calendar on page D-12 for these bar codes. Date

*%.*

When finished setting the date and time formats, press any function key to return to the program.

E-6

Falcon® PT40