Programming Parameters
Xmodem Protocol The PT40 supports the Xmodem (checksum) file-transfer protocol for serial communication, which is available in many commercially marketed products. Xmodem is a simple send-and-wait-for-response protocol using a fixed-length data field. The data field is embedded in an Xmodem packet, which also contains a packet number and a single-byte arithmetic checksum. The protocol link is established by the receiver transmitting a NAK character until the sender responds. The sender responds by transmitting an Xmodem packet. The sender then waits for either an ACK signal, in which case it transmits the next packet, or a NAK signal, in which case it retransmits the packet. Once all packets are transmitted, the sender transmits an EOT signal, indicating the end of transmission. Scan the following bar code to set a PT40 to use the Xmodem protocol:
*$+$-CA02EE*
Xmodem protocol
Save-and-Exit Settings Table E-4. Save-and-Exit Settings Setting
ID #
Type
Save and exit
EE
Immediate
Exit only, no save
EF
Immediate
Product Reference Guide
E-7
Page 102
2340.book Page 8 Wednesday, January 29, 2003 12:50 PM
Programming Parameters
Code 39 and ASCII Equivalents for Serial Characters Table E-5 provides Code 39 and ASCII equivalents for serial characters.
Table E-5. Code 39 and ASCII Equivalents for Serial Characters ASCII Hex ASCII Hex ASCII Hex ASCII NUL 00 SP 20 @ 40 SOH 01 ! 21 A 41 a STX 02 “ 22 B 42 b ETX 03 # 23 C 43 c EOT 04 $ 24 D 44 d ENQ 05 % 25 E 45 e ACK 06 & 26 F 46 f BEL 07 & 26 G 47 g BS 08 ( 28 H 48 h HT 09 ) 29 I 49 i LF 0A * 2A J 4A j VT 0B + 2B K 4B k FF 0C , 2C L 4C l CR 0D 2D M 4D m SO 0E . 2E N 4E n SI 0F / 2F O 4F o DLE 10 0 30 P 50 p DC1 11 1 31 Q 51 q DC2 12 2 32 R 52 r DC3 13 3 33 S 53 s DC4 14 4 34 T 54 t NAK 15 5 35 U 55 u SYN 16 6 36 V 56 v ETB 17 7 37 W 57 w CAN 18 8 38 X 58 x EM 19 9 39 Y 59 y SUB 1A : 3A Z 5A z ESC 1B ; 3B [ 5B { FS 1C < 3C \ 5C | GS 1D = 3D ] 5D } RS 1E > 3E ^ 5E ~ US 1F ? 3F _ 5F DEL
E-8
Hex 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
Falcon® PT40
Page 103
2340.book Page 9 Wednesday, January 29, 2003 12:50 PM
General Programming Parameters
General Programming Parameters Table E-6. General Programming Parameters Predefined Defaults Code Parameter
ID #
Type
Acceptable Input D0
Code 39 Enable
D1
D2
Enter 1 for On and 0 for Off. 00
On/Off
On or Off
Off
On
On
Minimum length
01
Value
00–60
00
00
00
Maximum length
02
Value
00–60
00
60
20
Enable checksum
03
On/Off
On or Off
Off
Off
Off
Send checksum
04
On/Off
On or Off
Off
Off
Off
Full ASCII mode
05
On/Off
On or Off
Off
On
On
Accumulate mode
06
On/Off
On or Off
Off
On
Off
Enable AIAG alternate check digit
07
On/Off
On or Off
Off
Off
Off
Interleaved 2 of 5
Enter 1 for On and 0 for Off.
Enable
08
On/Off
On or Off
Off
On
On
Minimum length
09
Value
02–60
02
02
06
Maximum length
0A
Value
02–60
02
60
10
Enable checksum
0B
On/Off
On or Off
Off
Off
Off
Send checksum
0C
On/Off
On or Off
Off
Off
Off
Use lengths 6 and 14 only (case code)
0D
On/Off
On or Off
Off
Off
Off
Codabar
Enter 1 for On and 0 for Off.
Enable
20
On/Off
On or Off
Off
On
On
Minimum length
21
Value
00–60
00
02
04
Maximum length
22
Value
00–60
00
60
20
Send start/stop
23
On/Off
On or Off
Off
Off
Off
Convert Codabar to CLSI
24
On/Off
On or Off
Off
Off
Off
Code 93
Enter 1 for On and 0 for Off.
Enable
2C
Minimum length
2D
Value
00–50
00
01
02
Maximum length
2E
Value
01–50
00
50
20
Product Reference Guide
On/Off
On or Off
Off
On
On
E-9
Page 104
2340.book Page 10 Wednesday, January 29, 2003 12:50 PM
Programming Parameters
Predefined Defaults Code Parameter
ID #
Type
Acceptable Input D0
Universal Product Code-A (UPC-A)
D1
D2
Enter 1 for On and 0 for Off.
Enable
30
On/Off
On or Off
Off
On
On
Send system digit
31
On/Off
On or Off
Off
On
On
Send check digit
32
On/Off
On or Off
Off
On
Off
Convert UPC-A to EAN-13
33
On/Off
On or Off
Off
On
Off
Universal Product Code-E (UPC-E)
Enter 1 for On and 0 for Off.
Use system digit 0
34
On/Off
On or Off
Off
On
On
Use system digit 1
35
On/Off
On or Off
Off
On
On
Convert UPC-E to UPC-A
36
On/Off
On or Off
Off
On
Off
Send system digit
37
On/Off
On or Off
Off
On
Off
Send check digit
38
On/Off
On or Off
Off
On
Off
European Article Numbering (EAN)/ Japan Article Numbering (JAN)
Enter 1 for On and 0 for Off.
Enable EAN-8/JAN-8
39
On/Off
On or Off
Off
On
On
Enable EAN-13/JAN-13
3A
On/Off
On or Off
Off
On
On
Convert EAN-13 to ISBN
3B
On/Off
On or Off
Off
Off
Off
Send check digit
3F
On/Off
On or Off
Off
Off
On
UPC, EAN, JAN Extensions
Enter 1 for On and 0 for Off.
Allow 2-digit extensions
3C
On/Off
On or Off
Off
On
On
Allow 5-digit extensions
3D
On/Off
On or Off
Off
On
On
Require extensions
3E
On/Off
On or Off
Off
Off
Off
Code 128
Enter 1 for On and 0 for Off.
Enable
40
On/Off
On or Off
Off
On
On
Minimum length
41
Value
00–60
00
02
02
Maximum length
42
Value
00–60
00
60
20
Enable UCC128
43
On/Off
On or Off
Off
Off
Off
E-10
Falcon® PT40
Page 105
2340.book Page 11 Wednesday, January 29, 2003 12:50 PM
General Programming Parameters
Predefined Defaults Code Parameter
ID #
Type
Acceptable Input D0
Other Controls
D1
D2
Enter 1 for On and 0 for Off.
Enable manual reset
B0
On/Off
On or Off
On
On
On
Add symbology identifiers
B5
On/Off
On or Off
Off
On
Off
Auto-Off
B2
Value
00–99 (minutes)
00
60
10
BackLight Timeout
E2
Value
00-99 (1 second units)
16
16
16
07
07
07
Beeper volume
BC
Value
00 = Off 01 (low) – 07 (high) 08 = One level higher 09 = One level lower
Contrast (LCD)
E3
Value
01 (low) – 63 (high)
16
16
16
Date format
D9
On/Off
On = International Off = U.S.
Off
Off
Off
Error tone
BD
Value
00 (low) – 07 (high)
03
03
03
Good-read tone
B8
Value
00 (low) – 07 (high)
05
05
05
Good-read number of beeps
B9
Value
01–04
01
01
01
01
01
01
Good-read tone duration
BA
Value
00 = 0.14 sec. 01 = 0.07 sec. 02 = 0.45 sec. 03 = 0.22 sec.
Keyboard click
DD
On/Off
On or Off
On
On
On
Keypad Timeout (Intercharacter delay)
E4
Value
00-99 (1/4 second units)
3
3
3
Laser delay
DE
Value
00–99 (10-millisecond units)
01
01
01
Time format
D8
On/Off
On = 24-hour Off = 12-hour
On
On
On
A = UPC-A B = Interleaved 2 of 5
Product Reference Guide
C = Code 39 E = UPC-E
G = EAN-8 I = Codabar
K = Code 128 L = Code 93
M = EAN-13
E-11
Page 106
2340.book Page 12 Wednesday, January 29, 2003 12:50 PM
Programming Parameters
Serial Parameters The PT40 is pre-configured at the factory with the parameter settings for serial communications found in Table E-7. Table E-7. Default Parameter Settings for Serial Communications Parameter
Default Setting
Baud rate
9600
Data bits
8
Parity
None
Stop bits
1
Enable Xon/Xoff
Off
Linefeed
None
Protocol
CR with checksun & ACK/NAK response
End of Record Character
CR
Timeout
1 second
Table E-8 specifies serial parameters. Refer to Serial Parameters starting on page D-12 for bar codes to set serial parameters. Table E-5 on page E-8 includes Code 39 and ASCII equivalents for serial characters. Use the Code 39 equivalents when creating bar codes for programming. For a complete listing of parameters and defaults, refer to Programming Parameters on page E-1. Table E-8. Serial Parameters ID #
Parameter
C1
Baud rate
Determines the communication speed. The setting for the PT40 must match the setting that the host computer uses.
C2
Data bits
Specifies the number of data bits in each character.
C3
Parity
Specifies the parity of the data characters.
C4
Stop bits
Selects the minimum space between data characters.
C5
E-12
Description
Used for software data-flow control. With this option enabled, the PT40 transmits an Xoff character when its serial input Xon/Xoff handbuffer has fewer than ten characters of free space. Once all the shaking data in the serial buffer is processed, the PT40 transmits an Xon character.
Falcon® PT40
Page 107
2340.book Page 13 Wednesday, January 29, 2003 12:50 PM
Serial Parameters
Table E-9. Serial Programming Parameters Code Parameter
ID #
Type
Acceptable Input
Serial Programming Parameter Host select
Predefined Default (C8)
Enter 1 for On and 0 for Off. C0
Value
11 = ATs, PS/2s, and compatibles 15 = IBM terminals
None
05
Baud rate
C1
Value
00 = 300 01 = 600 02 = 1200 03 = 2400 04 = 4800 05 = 9600 06 = 19,200 07 = 38,400 08 = 76,800
Data bits
C2
Value
07 = 7 bits 08 = 8 bits
08
Parity
C3
Value
00 = None 03 = Odd 04 = Even
00
Stop bits
C4
Value
01 = 1 bit 02 = 2 bits
01
Enable Xon/Xoff
C5
On/Off
On or Off
Off
Value
00 = None 01 = Strip LF 02 = Add LF
00
Value
Any single ASCII character
1A 01
Linefeed (LF) (Valid for CA = 00 only)
C6
Predefined serial defaults
C8
End-of-file character
C9
Protocol
CA
Value
00 = EOR only 01 = CR with checksum and ACK/NAK response 02 = Xmodem
End-of-record (EOR) character
CC
Value
Any single ASCII character
(CR)
Timeout
CD
Value
00–99 (100-millisecond units)
10
Product Reference Guide
E-13
Page 108
2340.book Page 14 Wednesday, January 29, 2003 12:50 PM
Programming Parameters
NOTES
E-14
Falcon® PT40
Page 109
2340.book Page 1 Wednesday, January 29, 2003 12:50 PM
Appendix F Memory Table Table F-1 shows the relationship between the number of characters, records, and files you can store on a Falcon PT40 based upon the amount of random access memory (RAM) installed on your PT40. Table F-1. Falcon PT40 Memory Record Size
Number of Records
Characters
256K Memory
2 Meg Memory
1-7
15,000
8 - 15
10,000
16 - 23
7,500
64,850
24 - 31
6,000
51,875
32 - 39
5,000
43,200
40 - 47
4,275
37,050
48 - 55
3,750
32,400
56 - 63
3,300
28,800
64 - 71
3,000
25,925
72 - 79
2,725
23,575
80 - 87
2,500
21,600
File #1 65,490 File #2 64,200 File #1 65,490 File #2 21,000
88 - 95
2,300
19,950
96 - 103
2,125
18,500
104 - 111
2,000
17,275
112 - 119
1,875
16,200
120 - 127
1,750
15,250
The maximum number of records per file = 65,490.