The text of a manual · part 9 of 13
Falcon PT40 Product Reference Guide, pages 81 to 90
Pages 81 to 90 of 122
The original document is the PDF (6.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC PT40 and Datalogic PT40
Page 81
2340.book Page 1 Wednesday, January 29, 2003 12:50 PM
Appendix D Configuring with Bar Codes This section provides bar codes for common setup parameters that can be used for programming the PSC PT40. Factory default settings are underlined.
Predefined Defaults DO
*$+$-D0EE*
D2
*$+$-D2EE*
D1
*$+$-D1EE*
Serial defaults
*$+$-C8EE*
*$+$-001EE*
Off
*$+$-000EE*
Code 39 ENABLE
On
MINIMUM LENGTH
00
*$+$-0100EE*
40
*$+$-0140EE*
10
*$+$-0110EE*
50
*$+$-0150EE*
20
*$+$-0120EE*
60
*$+$-0160EE*
Product Reference Guide
D-1
Page 82
2340.book Page 2 Wednesday, January 29, 2003 12:50 PM
Configuring with Bar Codes
30
*$+$-0130EE*
MAXIMUM LENGTH
10
*$+$-0210EE*
40
*$+$-0240EE*
20
*$+$-0220EE*
50
*$+$-0250EE*
30
*$+$-0230EE*
60
*$+$-0260EE*
Off
*$+$-030EE*
Off
*$+$-040EE*
Off
*$+$-050EE*
Off
*$+$-060EE*
Off
*$+$-070EE*
ENABLE CHECKSUM
On
*$+$-031EE*
SEND CHECKSUM
On
*$+$-041EE*
FULL ASCII MODE
On
*$+$-051EE*
ACCUMULATE MODE
On
*$+$-061EE*
ENABLE AIAG ALTERNATE CHECK DIGIT
On
D-2
*$+$-071EE*
Falcon® PT40
Page 83
2340.book Page 3 Wednesday, January 29, 2003 12:50 PM
Interleaved 2 of 5
Interleaved 2 of 5 ENABLE
On
*$+$-081EE*
Off
*$+$-080EE*
MINIMUM LENGTH
2
*$+$-0902EE*
30
*$+$-0930EE*
6
*$+$-0906EE*
40
*$+$-0940EE*
10
*$+$-0910EE*
50
*$+$-0950EE*
20
*$+$-0920EE*
60
*$+$-0960EE*
MAXIMUM LENGTH
10
*$+$-0A10EE*
40
*$+$-0A40EE*
20
*$+$-0A20EE*
50
*$+$-0A50EE*
30
*$+$-0A30EE*
60
*$+$-0A60EE*
REQUIRED LENGTH (no default; overrides minimum and maximum settings)
2
*$+$-09020A02EE* 12 *$+$-09120A12EE*
4
*$+$-09040A04EE* 14 *$+$-09140A14EE*
Product Reference Guide
D-3
Page 84
2340.book Page 4 Wednesday, January 29, 2003 12:50 PM
Configuring with Bar Codes
6
*$+$-09060A06EE* 16 *$+$-09160A16EE*
8
*$+$-09080A08EE* 18 *$+$-09180A18EE*
10
*$+$-09100A10EE* 20 *$+$-09200A20EE*
ENABLE CHECKSUM
*$+$-0B1EE*
On
Off
*$+$-0B0EE*
Off
*$+$-0C0EE*
Off
*$+$-0D0EE*
SEND CHECKSUM
*$+$-0C1EE*
On
USE LENGTHS 6 AND 14 ONLY (case code)
*$+$-0D1EE*
On
Codabar ENABLE
On
*$+$-201EE*
Off
*$+$-200EE*
MINIMUM LENGTH
D-4
04
*$+$-2104EE*
40
*$+$-2140EE*
10
*$+$-2110EE*
50
*$+$-2150EE* Falcon® PT40
Page 85
2340.book Page 5 Wednesday, January 29, 2003 12:50 PM
Code 93
20
*$+$-2120EE*
30
*$+$-2130EE*
60
*$+$-2160EE*
MAXIMUM LENGTH
10
*$+$-2210EE*
40
*$+$-2240EE*
20
*$+$-2220EE*
50
*$+$-2250EE*
30
*$+$-2230EE*
60
*$+$-2260EE*
Off
*$+$-230EE*
*$+$-241EE*
Off
*$+$-240EE*
*$+$-2C1EE*
Off
*$+$-2C0EE*
30
*$+$-2D30EE*
SEND STOP/START
On
*$+$-231EE*
CONVERT CODABAR TO CLSI
On
Code 93 ENABLE
On
MINIMUM LENGTH
2
*$+$-2D02EE*
Product Reference Guide
D-5
Page 86
2340.book Page 6 Wednesday, January 29, 2003 12:50 PM
Configuring with Bar Codes
10
*$+$-2D10EE*
40
*$+$-2D40EE*
20
*$+$-2D20EE*
50
*$+$-2D50EE*
MAXIMUM LENGTH
2
*$+$-2E02EE*
30
*$+$-2E30EE*
10
*$+$-2E10EE*
40
*$+$-2E40EE*
20
*$+$-2E20EE*
50
*$+$-2E50EE*
Off
*$+$-300EE*
Off
*$+$-310EE*
Off
*$+$-320EE*
Off
*$+$-330EE*
UPC-A ENABLE UPC-A
On
*$+$-301EE*
SEND SYSTEM DIGIT
On
*$+$-311EE*
SEND CHECK DIGIT
On
*$+$-321EE*
CONVERT UPC-A TO EAN-13
On
D-6
*$+$-331EE*
Falcon® PT40
Page 87
2340.book Page 7 Wednesday, January 29, 2003 12:50 PM
UPC-E
UPC-E USE SYSTEM DIGIT 0
On
*$+$-341EE*
Off
*$+$-340EE*
Off
*$+$-350EE*
Off
*$+$-360EE*
Off
*$+$-370EE*
Off
*$+$-380EE*
Off
*$+$-390EE*
Off
*$+$-3A0EE*
USE SYSTEM DIGIT 1
On
*$+$-351EE*
CONVERT UPC-E TO UPC-A
On
*$+$-361EE*
SEND SYSTEM DIGIT
On
*$+$-371EE*
SEND CHECK DIGIT
On
*$+$-381EE*
EAN/JAN ENABLE EAN-8/JAN-8
On
*$+$-391EE*
ENABLE EAN-13/JAN-13
On
*$+$-3A1EE*
Product Reference Guide
D-7
Page 88
2340.book Page 8 Wednesday, January 29, 2003 12:50 PM
Configuring with Bar Codes
CONVERT EAN-13 TO ISBN
*$+$-3B1EE*
On
Off
*$+$-3B0EE*
Off
*$+$-3F0EE*
Off
*$+$-3C0EE*
Off
*$+$-3D0EE*
*$+$-3E1EE*
Off
*$+$-3E0EE*
*$+$-401EE*
Off
*$+$-400EE*
40
*$+$-4140EE*
SEND CHECK DIGIT
*$+$-3F1EE*
On
UPC/EAN/JAN Extensions ALLOW 2-DIGIT EXTENSIONS
*$+$-3C1EE*
On
ALLOW 5-DIGIT EXTENSIONS
*$+$-3D1EE*
On
REQUIRE EXTENSIONS
On
Code 128 ENABLE
On
MINIMUM LENGTH
2
D-8
*$+$-4102EE*
Falcon® PT40
Page 89
2340.book Page 9 Wednesday, January 29, 2003 12:50 PM
Other Controls
10
*$+$-4110EE*
50
*$+$-4150EE*
20
*$+$-4120EE*
60
*$+$-4160EE*
30
*$+$-4130EE*
MAXIMUM LENGTH
10
*$+$-4210EE*
40
*$+$-4240EE*
20
*$+$-4220EE*
50
*$+$-4250EE*
30
*$+$-4230EE*
60
*$+$-4260EE*
Off
*$+$-430EE*
*$+$-B01EE*
Off
*$+$-B00EE*
*$+$-B51EE*
Off
*$+$-B50EE*
ENABLE UCC128
On
*$+$-431EE*
Other Controls ENABLE MANUAL RESET
On ADD CODE ID
On
Product Reference Guide
D-9
Page 90
2340.book Page 10 Wednesday, January 29, 2003 12:50 PM
Configuring with Bar Codes
AUTO-OFF (in minutes)
Off
*$+$-B200EE*
30
*$+$-B230EE*
5
*$+$-B205EE*
60
*$+$-B260EE*
10
*$+$-B210EE*
90
*$+$-B290EE*
BACKLIGHT DURATION (in seconds)
Always On
*$+$-E200EE*
30
*$+$-E215EE*
10
*$+$-E210EE*
60
*$+$-E260EE*
BEEPER VOLUME
Increase
*$+$-BC08EE*
Low
*$+$-BC01EE*
Decrease
*$+$-BC09EE*
High
*$+$-BC07EE*
Off
*$+$-BC00EE* High
*$+$-BD07EE*
ERROR TONE
Low
*$+$-BD01EE*
Medium
*$+$-BD04EE*
D-10
Falcon® PT40