PowerWedge 20 User's Guide: Programming Options
Pages 66 to 79 of 148, from PowerWedge 20 User's Guide
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC Powerwedge 20 and Datalogic Powerwedge 20
Page 66
Programming Options
Programming Options Table 12 lists programming I.D. numbers for predefined defaults, which provide a fast and easy way to set all parameters off, on, or to factory settings. Table 13 lists cloning, display, and save-and-exit settings. Table 14 provides the following information:
NOTE
For explanations of some general programming parameters, see page 34. For explanations of serial parameters, see page 36. For information about magnetic stripe programming parameters, see page 44. For input-editing parameters, see Input Editing on page 45.
•
Code Parameter is the “human” name for programming options.
•
I.D. # is the “decoder” name for programming options. For example, if you wanted to set a Code 39 minimum label length, you would enter 01 when programming the decoder. Programming I.D. numbers given in this section can be used with all programming methods.
•
Type tells what kind of setting to use for each code parameter:, On/Off is a toggle. 1 turns the parameter on, and 0 turns it off., Value requires a two-character entry (e.g., 02 for two beeps after each good read, or 05 for a length of five)., String uses one or more ASCII characters, followed by // to indicate the end of the string., Immediate takes effect as soon as the I.D. number is entered.
60
PowerWedge® 20
Page 67
Programming Options
•
Acceptable Input gives the settings or range of settings that you can use for each code parameter.
•
Predefined Defaults tells how the parameter is set when you select predefined default D0, D1, or D2 (see page 18).
Table 15 lists parameter settings for serial communications. Table 12. Predefined Defaults SETTING
I.D. #
TYPE
Predefined default set 0
D0
Immediate
Predefined default set 1
D1
Immediate
Predefined default set 2
D2
Immediate
Table 13. Cloning, Display, and Save-and-Exit Settings SETTING
I.D. #
TYPE
Cloning
EC
Immediate
Display settings (on-screen programming only)
ED
Immediate
Save and exit
EE
Immediate
Exit only, no save
EF
Immediate
User’s Guide
61
Page 68
Programming Options
Table 14. General Programming Parameters
CODE PARAMETER
I.D. #
TYPE
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
Code 39
D2
Enter 1 for On and 0 for Off.
Enable
00
On/Off
On or Off
Off
On
On
Minimum length
01
Value
00–50
00
00
00
Maximum length
02
Value
01–50
01
50
20
Enable checksum
03
On/Off
On or Off
Off
Off
Off
Send checksum
04
On/Off
On or Off
Off
Off
Off
Full ASCII mode
05
On/Off
On or Off
Off
On
On
MIL-STD-1189 support
07
On/Off
On or Off
Off
On
Off
Interleaved 2 of 5
Enter 1 for On and 0 for Off.
Enable
08
On/Off
On or Off
Off
On
On
Minimum length
09
Value
02–50
02
02
06
Maximum length
0A
Value
02–50
02
50
10
Enable checksum
0B
On/Off
On or Off
Off
Off
Off
Send checksum
0C
On/Off
On or Off
Off
Off
Off
Use lengths 6 and 14 only
0D
On/Off
On or Off
Off
Off
Off
Matrix 2 of 5
62
D1
Enter 1 for On and 0 for Off.
Enable
10
On/Off
On or Off
Off
On
Off
Minimum length
11
Value
01–50
01
01
06
Maximum length
12
Value
01–50
01
50
10
PowerWedge® 20 table
Page 69
Programming Options
Table 14. General Programming Parameters (Continued)
CODE PARAMETER
I.D. #
TYPE
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
D1
D2
Enable checksum
13
On/Off
On or Off
Off
Off
Off
Send checksum
14
On/Off
On or Off
Off
Off
Off
Standard 2 of 5
Enter 1 for On and 0 for Off.
Enable
15
On/Off
On or Off
Off
On
Off
Minimum length
16
Value
01–50
01
01
06
Maximum length
17
Value
01–50
01
50
10
Enable checksum
18
On/Off
On or Off
Off
Off
Off
Send checksum
19
On/Off
On or Off
Off
Off
Off
Use 2-bar start/stop
1A
On/Off
On or Off
Off
Off
Off
Code 11
Enter 1 for On and 0 for Off.
Enable
1B
On/Off
On or Off
Off
On
Off
Minimum length
1C
Value
01–50
01
01
04
Maximum length
1D
Value
01–50
01
50
10
Require 2 check digits
1E
On/Off
On or Off
Off
Off
Off
Send check digit(s)
1F
On/Off
On or Off
Off
On
Off
Codabar/Ames
Enter 1 for On and 0 for Off.
Enable
20
On/Off
On or Off
Off
On
On
Minimum length
21
Value
01–50
01
01
04
Maximum length
22
Value
01–50
01
50
20
Send start/stop
23
On/Off
On or Off
Off
Off
Off
User’s Guide
63 table
Page 70
Programming Options
Table 14. General Programming Parameters (Continued)
CODE PARAMETER
I.D. #
TYPE
PREDEFINED DEFAULTS D0
D1
D2
Codabar-to-CLSI conversion
24
On/Off
On or Off
Off
Off
Off
Wide intercharacter gaps allowed
25
On/Off
On or Off
Off
On
Off
MSI
Enter 1 for On and 0 for Off.
Enable
26
On/Off
On or Off
Off
On
Off
Minimum length
27
Value
01–14
01
01
04
Maximum length
28
Value
01–14
01
14
10
Require 2 check digits
29
On/Off
On or Off
Off
Off
Off
2nd check digit Mod 11
2A
On/Off
On or Off
Off
Off
Off
Send check digit(s)
2B
On/Off
On or Off
Off
On
Off
Code 93
Enter 1 for On and 0 for Off.
Enable
2C
On/Off
On or Off
Off
On
On
Minimum length
2D
Value
00–50
00
01
02
Maximum length
2E
Value
00–50
00
50
20
Universal Product Code-A (UPC-A)
64
ACCEPTABLE INPUT
Enter 1 for On and 0 for Off.
Enable
30
On/Off
On or Off
Off
On
On
Send system digit
31
On/Off
On or Off
Off
On
On
Send check digit
32
On/Off
On or Off
Off
On
Off
Convert UPC-A to EAN-13
33
On/Off
On or Off
Off
On
Off
PowerWedge® 20 table
Page 71
Programming Options
Table 14. General Programming Parameters (Continued)
CODE PARAMETER
I.D. #
TYPE
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
Universal Product Code-E (UPC-E)
D1
D2
Enter 1 for On and 0 for Off.
Use system digit 0
34
On/Off
On or Off
Off
On
On
Use system digit 1
35
On/Off
On or Off
Off
On
On
Convert UPC-E to UPC-A
36
On/Off
On or Off
Off
On
Off
Send system digit
37
On/Off
On or Off
Off
On
Off
Send check digit
38
On/Off
On or Off
Off
On
Off
European Article Numbering (EAN) Japan Article Numbering (JAN)
Enter 1 for On and 0 for Off.
Enable EAN-8/JAN-8
39
On/Off
On or Off
Off
On
On
Enable EAN-13/JAN-13
3A
On/Off
On or Off
Off
On
On
Convert EAN-13 to ISBN
3B
On/Off
On or Off
Off
Off
Off
Transmit EAN/JAN checksum
3F
On/Off
On or Off
Off
Off
Off
UPC, EAN, JAN EXTENSIONS
Enter 1 for On and 0 for Off.
Allow 2-digit extensions
3C
On/Off
On or Off
Off
On
On
Allow 5-digit extensions
3D
On/Off
On or Off
Off
On
On
Require extensions
3E
On/Off
On or Off
Off
Off
Off
Code 128
Enter 1 for On and 0 for Off.
Enable
40
On/Off
On or Off
Off
On
On
Minimum length
41
Value
01–50
01
01
02
Maximum length
42
Value
01–50
01
50
20
User’s Guide
65 table
Page 72
Programming Options
Table 14. General Programming Parameters (Continued)
CODE PARAMETER
Enable UCC128
I.D. #
43
TYPE
On/Off
Labelcode 4/5
ACCEPTABLE INPUT
On or Off
PREDEFINED DEFAULTS D0
D1
D2
Off
Off
Off
Enter 1 for On and 0 for Off.
Enable
52
On/Off
On or Off
Off
On
Off
Convert
53
On/Off
On or Off
Off
Off
Off
Magnetic Stripe Channel 1
Enter 1 for On and 0 for Off.
Enable
44
On/Off
On or Off
Off
On
On
Required
45
On/Off
On or Off
Off
Off
Off
Preamble
48
String
*
//
1 //†
//
Postamble
49
String
*
//
1//§
//
*Any supported keyboard keys, up to the maximum length supported by available total memory (about 130 characters) † Includes a space after the 1 §Includes a space before the 1
Magnetic Stripe Channel 2 table
Enter 1 for On and 0 for Off.
Enable
4A
On/Off
On or Off
Off
On
On
Required
4B
On/Off
On or Off
Off
Off
Off
Preamble
4E
String
*
//
2 //†
//
Postamble
4F
String
*
//
2//§
//
*Any supported keyboard keys, up to the maximum length supported by available total memory (about 130 characters) †Includes a space after the 2 §Includes a space before the 2
66
PowerWedge® 20
Page 73
Programming Options
Table 14. General Programming Parameters (Continued)
CODE PARAMETER
I.D. #
TYPE
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
Magnetic Stripe Channel 3
D1
D2
Enter 1 for On and 0 for Off.
Enable
54
On/Off
On or Off
Off
On
Off
Required
55
On/Off
On or Off
Off
Off
Off
Preamble
58
String
*
//
3 //†
//
Postamble
59
String
*
//
3//§
//
Auxiliary serial and magnetic stripe identifiers
5A
String
**
‡
‡
‡
Bar code symbology identifiers
5B
String
§§
‡
‡
‡
California DL/ID alpha conversion
5C
On/Off
On or Off
Off
On
On
*Any supported keyboard keys, up to the maximum length supported by available total memory (about 130 characters) †Includes a space after the 3 §Includes a space before the 3 **0 = Auxiliary serial 1 = Magnetic stripe channel 1 2 = Magnetic stripe channel 2 3 = Magnetic stripe channel 3 ‡See I.D. #B5 on page 68 for default settings §§0 = UPC-A 5 = S 2 of 5 A = Code 128 Select the I.D. letter for the ††1 = I 2 of 5 symbology you want to 6 = EAN-8 B = EAN 13 ††2 = Code 39 change, and then enter a 7 = MSI C = Labelcode 4/5 string followed by //. †† 3 = M 2 of 5 8 = Codabar/Ames ††4 = UPC-E 9 = Code 11
User’s Guide table
67
Page 74
Programming Options
Table 14. General Programming Parameters (Continued)
CODE PARAMETER
I.D. #
TYPE
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
Other Controls
D1
D2
Enter 1 for On and 0 for Off.
Programming mode
B0
Value
00 = Off 01 = Serial batch 02 = Menu 03 = Both
02
02
02
Autoterminator
B1
Value
Any single ASCII character (00 = Off)
(CR)
(CR)
(CR)
ASCII capital to lowercase
B2
On/Off
On or Off
Off
Off
Off
Intercharacter delay
B3
Value
00–99 (milliseconds)
00
00
00
CCD/laser redundancy
B4
On/Off
On or Off
Off
Off
Off
Send assigned symbology identifiers*
B5
On/Off
On or Off
Off
On
Off
*Bar Code A = UPC-A H = MSI B = I 2 of 5 I = Codabar/Ames C = Code 39 J = Code 11 D = M 2 of 5 K = Code 128 E = UPC-E M = EAN-13 F = S 2 of 5 N = Labelcode 4/5 G = EAN-8
Magnetic Stripe 1 = Channel 1 2 = Channel 2 3 = Channel 3 Other S = Auxiliary serial
Bar code preamble
B6
String
†
//
§
//
Bar code postamble
B7
String
†
//
**
//
†
Any supported keyboard keys, up to the maximum length supported by available total memory (about 130 characters) §CODEID // (includes a space after CODEID)
68
PowerWedge® 20 table
Page 75
Programming Options
Table 14. General Programming Parameters (Continued)
CODE PARAMETER
I.D. #
TYPE
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
Other Controls (continued)
D1
D2
Enter 1 for On and 0 for Off.
Good-read tone
B8
Value
00 = 3600 Hz 01 = 3840 Hz 02 = 4114 Hz 03 = 4430 Hz 04 = 2400 Hz 05 = 2618 Hz 06 = 2880 Hz 07 = 3200 Hz
04
04
04
Good-read number of beeps
B9
Value
01–04
01
01
01
Good-read tone duration
BA
Value
00 = 0.07 sec. 01 = 0.13 sec. 02 = 0.18 sec. 03 = 0.36 sec.
00
00
00
End-of-transmission beep
BB
On/Off
On or Off
Off
On
Off
Beeper volume
BC
Value
00 = Off 01 = Low 02 = Medium 03 = High
03
03
03
Laser connected to INPUT 2 (Dual model only)
BD
On/Off
On or Off
Off
Off
Off
Interfunction delay
BE
Value
00–99 (milliseconds)
00
00
00 table
Use numeric keypad
BF
On/Off
On or Off
Off
Off
Off
Strip Motorola data identifiers
D3
On/Off
On or Off
Off
Off
Off
User’s Guide
69
Page 76
Programming Options
Table 14. General Programming Parameters (Continued)
CODE PARAMETER
I.D. #
TYPE
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
Other Controls (continued)
D1
D2
Enter 1 for On and 0 for Off.
Laser/input modes
D4
Value
00 = Normal 01 = Autoscan 02 = Multiscan 03 = Symbol blinking
00
00
00
Require keyboard
D5
On/Off
On or Off
On
On
On
Autoscan timeout
D6
Value
01–99 (minutes) 00 = 256 minutes
30
30
30
CTRL out at power-up
D7
On/Off
On = High Off = Low
On
On
On
Bar code preamble for INPUT 2 (Dual model only)
DA
String
*
//
†
//
Bar code postamble for
DB
String
*
//
§
//
INPUT 2 (Dual model only)
table
*Any supported keyboard keys, up to the maximum length supported by available total memory (about 130 characters) †INPUT2 // (includes a space after INPUT2) § TEST// (includes a space before TEST)
70
PowerWedge® 20
Page 77
Programming Options
Table 14. General Programming Parameters (Continued)
CODE PARAMETER
Host device
I.D. #
C0
TYPE
Value
ACCEPTABLE INPUT
*
PREDEFINED DEFAULTS D0
D1
D2
None
None
None
*00 = IBM PC (international keyboard) 01 = IBM AT, PS/2 30-286, 50, 50Z, 60, 70, 80, 90, 95 (international keyboard) 02 = IBM PS/2 25, 30 (international keyboard) NOTE: Settings 00–02 work with DOS only. They transmit the ASCII character set and are not full-keyboard compatible. 10 = IBM PC (U.S. keyboard) 11 = IBM AT, PS/2 30-286, 50, 50Z, 60, 70, 80, 90, 95 (U.S. keyboard); ADDS terminals; NCR 2900; I/O Corp 2476 12 = IBM PS/2 25, 30 (U.S. keyboard) 15 = IBM and Telex terminals (102-key keyboard) 17 = IBM and Telex terminals (122-key keyboard); Decision Data models 3496 and 3781 21 = Macintosh (U.S. keyboard) 25 = Data General D213, D413 32 = TeleVideo 40 = DEC 42 = NEC PowerMate 50 = Serial ASCII 51 = Serial PC scan codes NOTE: The host devices listed above were supported at the time this user’s guide was printed. Additional devices may also be supported. Please contact your dealer or Customer Service for current information.
User’s Guide
71
Page 78
Programming Options s
Table 15. Serial Programming Parameters CODE PARAMETER
I.D. #
TYPE
ACCEPTABLE INPUT
PREDEFINED DEFAULT (C8)
Enter 1 for On and 0 for Off. Data type
C0
Value
50 = ASCII 51 = PC scan codes
50
Baud rate
C1
Value
00 = 300 01 = 600 02 = 1200 03 = 2400 04 = 4800 05 = 9600 06 = 19200 07 = 38400 08 = 57600
05
Data bits*
C2
Value
07 = 7 Bits 08 = 8 Bits
08
Parity*
C3
Value
00 = None 01 = Mark 02 = Space 03 = Odd 04 = Even
00
Stop bits*
C4
Value
01 = 1 Bit 02 = 2 Bits
01
Xon/Xoff handshaking
C5
On/ Off
On or Off
Off
Enable auxiliary serial input
C7
On/ Off
On or Off
Off
Predefined serial defaults
C8
Protocol
CA
Value
00 = EOR only 01 = ACK/NAK
00
*The PowerWedge 20 will not operate with a combination of 7 data bits, no parity, and 1 stop bit
72
PowerWedge® 20 table
Page 79
Programming Options
Table 15. Serial Programming Parameters (Continued) I.D. #
TYPE
End-of-record (EOR) character
CC
Value
Any single ASCII character
(CR)
Timeout
CD
Value
01–99* 00 = 2.55 seconds
03
Require host response
CE
On/ Off
On or Off
Off
Use host-controlled indicators
CF
On/ Off
On or Off
Off
CODE PARAMETER
ACCEPTABLE INPUT
PREDEFINED DEFAULT (C8)
*10-millisecond increments; the default setting (03) means 30 milliseconds
User’s Guide
73