The text of a manual · part 7 of 15
PowerWedge 20 User's Guide: Input Editing
Pages 51 to 65 of 148, from PowerWedge 20 User's Guide
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC Powerwedge 20 and Datalogic Powerwedge 20
Page 51
Input Editing
Input Editing The PowerWedge 20 gives you the ability to modify input from bar code scanners, magnetic stripe readers, auxiliary serial devices, and keyboards. This feature is known as input editing. With input editing, you program the decoder to change the format of the input data before it sends the data to your computer or terminal. You can program your decoder for input editing using any programming method (see Programming the PowerWedge 20 on page 17).
table
User’s Guide
45
Page 52
Input Editing
Table 5 shows just a few of the many uses for input editing. Table 5. Examples of Input Editing By programming the decoder to …
You can change this …
To this …
Delete the first three characters of each string
A0037066 A0037067
37066 37067
Separate the input into two fields separated by a space
A0037066 A0037067
A 0037066 A 0037067 or A003 7066 A003 7067
Separate the input into three fields separated by dashes
A0037066 A0037067
A-003-7066 A-003-7067
Rearrange the order of the fields
A0037066 A0037067
0037066A 0037067A
Separate the input into fields separated by commas and rearrange the order of the fields
A0037066 A0037067
7066,A003 7067,A003
Add text to the data
A0037066 A0037067
Ser. #A0037066 Ser. #A0037067 or A0037066 Jan/95 A0037067 Jan/95
Input editing overrides standard preamble and postamble settings. Programmed preambles and postambles will be attached only to data input that doesn’t qualify for editing (see the next section).
46
PowerWedge® 20
Page 53
Input Editing
Creating Qualification Definitions To qualify for input editing, the data that enters the decoder must meet certain criteria that you define. For example, you may require the data to be Code 39, to have exactly ten numbers or letters, and to end with an X. These criteria make up a qualification definition. Any input that meets all the criteria for a definition will be edited according to the parameters that you set for it and output in the format that you specify. You can create up to four different qualification definitions for input editing. The definitions are numbered 1 through 4, and each definition has its own set of I.D. numbers for programming parameters (see Table 6). Parameters for each definition include the following:
User’s Guide
•
Symbology This specifies whether the data must be of a particular bar code type or come from a specific magnetic stripe channel, an auxiliary serial device, or keyboard input. Only data of the designated symbology can be considered for qualification. (This parameter can also be set to consider any input regardless of symbology or source.)
•
Record length This specifies what length (from 1 through 99 characters) the data must be. Only data of the designated length will be considered. (This parameter can also be set to consider data of any length.)
•
Number of input fields This specifies into how many fields (from 1 through 8) the input data will be broken down. Each field can then be defined as a specific number of characters (or any number of characters) beginning with a specific character (or any character).
•
Output sequence This specifies the order in which to output the defined fields. The output sequence can also include additional information, such as symbology identifiers, preambles, postambles, or up to 16 extra fields that contain text strings. These extra fields are numbered 0 through 9 and A through F; each field has its own programming I.D. number. (For more information about output sequencing, see Understanding Output Sequences on page 51.)
47
Page 54
Input Editing
When data is read, the decoder processes the definitions in numerical order. If the input data qualifies under definition 1, the decoder edits and outputs the data; if the data does not qualify under definition 1, the decoder tries definition 2. The process continues in order through all four definitions, and the data is edited according to the first definition under which it qualifies; the other definitions are not used. If the data doesn’t qualify under any of the four definitions, then the decoder outputs the data without editing it.
If the “allow qualified data only” parameter (I.D. #AD) is enabled, no data will be output unless it qualifies under one of the definitions. NOTE
Parameters for Input-Editing Definitions Table 6 lists I.D. numbers and predefined defaults for parameters for input-editing definitions 1 through 4. You can change your decoder’s settings for these parameters using the bar code menu, bar code batch, serial batch, or on-screen method of programming. Table 6. Input Editing Parameters
PARAMETER
I.D. #
PREDEFINED DEFAULTS
TYPE D0
D1
D2
Definition 1
Enter 1 for On and 0 for Off.
Enable
70
On/Off
Off
On
Off
Symbology (0 = any; for other values, see I.D. #B5 on page 52)
71
Value
0
C
0
Record length (01–99, or 00 for any)
72
Value
00
00
00
48
PowerWedge® 20 table
Page 55
Input Editing
Table 6. Input Editing Parameters (Continued)
PARAMETER
Number of fields (01–08)
I.D. #
73
PREDEFINED DEFAULTS
TYPE D0
D1
D2
01
05
01
Value
Fields 1–8 (length followed by qualifier; 00 = any length; (00) = any qualifier) Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Field 7 Field 8
74 75 76 77 78 79 7A 7B
Field
00(00)
00(00) 01! 00(00) 01= 03(00) 00(00) 00(00) 00(00)
00(00)
Output sequence (see Table 7)
7C
String
//
*
//
*60610561036201B1// (see Understanding Output Sequences on page 51, for explanation)
Definition 2
Enter 1 for On and 0 for Off.
Enable
80
On/Off
Off
Off
Off
Symbology (0 = any; for other values, see I.D. #B5 on page 52)
81
Value
0
0
0
Record length (01–99, or 00 for any)
82
Value
00
00
00
Number of fields (01–08)
83
Value
01
01
01
Fields (length followed by qualifier; 00 = any length; (00) = any qualifier) Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Field 7 Field 8
84 85 86 87 88 89 8A 8B
Field
00(00)
00(00)
00(00)
Output sequence (see Table 7)
8C
String
//
//
//
User’s Guide
49 table
Page 56
Input Editing
Table 6. Input Editing Parameters (Continued)
PARAMETER
I.D. #
PREDEFINED DEFAULTS
TYPE D0
D1
D2
Definition 3
Enter 1 for On and 0 for Off.
Enable
90
On/Off
Off
Off
Off
Symbology (0 = any; for other values, see I.D. #B5 on page 52)
91
Value
0
0
0
Record length (01–99, or 00 for any)
92
Value
00
00
00
Number of fields (01–08)
93
Value
01
01
01
00(00)
00(00)
00(00)
Fields (length followed by qualifier; 00 = any length; (00) = any qualifier) Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Field 7 Field 8
94 95 96 97 98 99 9A 9B
Field
Output sequence (see Table 7)
9C
String
50 table
//
//
//
PowerWedge® 20
Page 57
Input Editing
Table 6. Input Editing Parameters (Continued) I.D. #
PARAMETER
PREDEFINED DEFAULTS
TYPE D0
D1
D2
Definition 4
Enter 1 for On and 0 for Off.
Enable
A0
On/Off
Off
Off
Off
Symbology (0 = any; for other values, see I.D. #B5 on page 52)
A1
Value
0
0
0
Record length (01–99, or 00 for any)
A2
Value
00
00
00
Number of fields (01–08)
A3
Value
01
01
01
Fields (length followed by qualifier; 00 = any length; (00) = any qualifier) Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Field 7 Field 8
A4 A5 A6 A7 A8 A9 AA AB
Field
00(00)
00(00)
00(00)
Output sequence (see Table 7)
AC
String
//
//
//
Allow qualified data only
AD
On/Off
Off
Off
Off
Understanding Output Sequences An output sequence does not contain any text that will actually be output; it contains pointers to fields, which may contain input data or text strings. For example, you cannot include a comma in an output sequence; instead, you must include the output-sequence value of the field containing a comma. An output sequence can also contain autoterminators, preambles, and postambles. Each field and other type of information is assigned a specific value (either the field number or letter, or the parameter I.D. number) for inclusion in the output sequence (see Table 7). User’s Guide
51
Page 58
Input Editing
Each output sequence must end with an end-of-string character (//). Each input editing definition has its own output sequence with its own I.D. number. The order of the values in the output sequence determines the order in which the field contents and other information will appear in the output. If a field is not included in the output sequence, its contents will be stripped from the data during input editing. Table 7. Output Sequence Settings TYPE OF INFORMATION
Fields 01–08
ACTUAL OUTPUT
01–08
The contents of each specified field
Magnetic stripe preambles Channel 1 Channel 2 Channel 3
48 4E 58
Magnetic stripe postambles Channel 1 Channel 2 Channel 3
49 4F 59
A text string
A text string
Extra fields
60–6F
The contents of each specified field; see Using Extra Fields on page 53
Redirection commands
90–96
None; see Table 9
Autoterminator
B1
A single ASCII character
Symbology identifier
B5
A code identifying the input form
End-of-string character (//)
52
VALUE USED IN OUTPUT SEQUENCE
Must be used to end each output sequence
PowerWedge® 20
Page 59
Input Editing
Using Extra Fields You can define up to 16 extra fields for input editing. Use the extra fields to include text strings or keyboard actions. For example, by defining one field to contain the word aisle, another field to contain the word bin, a third field to contain a tab, and another field to contain a space, you can change N21263 to aisle N21 bin 263
You can include the value for each extra field in the output sequence of any or all of the qualification definitions. Table lists I.D. numbers and predefined defaults for extra fields. You can change your decoder’s settings for these parameters using the bar code menu, bar code batch, serial batch, or on-screen method of programming. Table 8. Extra-Field Parameters PARAMETER
I.D. #
TYPE
Extra field 0
60
Extra field 1 Extra field 2 Extra fields 3–16
D0
D1
D2
String
//
Acc#//
//
61
String
//
//*
//
62
String
//
, //†
//
63–6F§
String
//
//
//
*Two spaces †A comma followed by a space §Extra field 3 = 63 Extra field 8 = 68 Extra field 4 = 64 Extra field 9 = 69 Extra field 5 = 65 Extra field A = 6A Extra field 6 = 66 Extra field B = 6B Extra field 7 = 67 Extra field C = 6C
User’s Guide
PREDEFINED DEFAULTS
Extra field D = 6D Extra field E = 6E Extra field F = 6F
53
Page 60
Input Editing
Redirecting Output After input editing, data is normally output to the host computer or terminal. You can include output-redirection commands or system commands in the output sequence to redirect the data output (see Table 9). Table 9. Output-Redirection Settings
54
VALUE USED IN OUTPUT SEQUENCE
EFFECT
90
Switches output back to the host after data has been redirected
91
Redirects data as control commands to be sent to the system’s host-controlled indicator (HCI) parser (see )
92–95
Redirects data to the serial port’s handshake-out line using the following settings:
92 93 94 95
9600 baud, 8 data bits, no parity, 1 stop bit 9600 baud, 7 data bits, even parity, 1 stop bit 2400 baud, 8 data bits, no parity, 1 stop bit 2400 baud, 7 data bits, even parity, 1 stop bit
96
Redirects data to the serial port’s Tx line
PowerWedge® 20
Page 61
Input Editing
An Input Editing Example
NOTE
To read the bar codes in this example, your PowerWedge 20 decoder must accept Code 39 bar codes with a maximum length of 26 characters. Scan the following bar code to reset your decoder to predefined default D2 and set the maximum length for Code 39 bar codes to 26:
*$+$-D20226EE* Let’s say you are the head of security for a large manufacturing company. Each employee in your company has an identification badge with a Code 39 bar code containing the employee’s first name and last name, a five-digit employee number that begins with 0, and sometimes additional information. Names, numbers, and other information in the bar codes are separated by periods, as in the following example:
*SALLY.ROGERS.01836.MGR* To enter certain areas of the building, employees must present their badges to an I.D. badge reader that passes the data through a PowerWedge 20 to a central computer. The information output to the computer also includes the location of the I.D. badge reader. The output is in the following format: Last name, First nameEmp. #Location Today you are installing a badge reader and decoder at a new location called Area M, and you need to program the decoder to output the data in the proper format. Using the example above, you want the output to be as follows: Rogers, Sally1836Area M To get the results you want, you need to complete three steps.
User’s Guide
55
Page 62
Input Editing
Step 1: Create a Qualification Definition The definition will require the input to be Code 39 data of any length and will break that data down into seven fields, including (1) first name, (3) last name, (5) employee number with the leading zero dropped off, and (7) other information, as shown below:
*SALLY.ROGERS.01836.MGR* 1
2
3
4
5
6
7
Any input that doesn’t meet the definition criteria will not be edited. Table 10 lists the parameters and values you need to use. If you are using predefined defaults (see page 18), you need to program only the parameters whose values are different from the defaults. For example, the D1 default setting for I.D. #71 (definition 1 symbology) is C (Code 39); so if your decoder is using the D1 settings, you do not need to set I.D. #71. Table 10. Parameter Settings for the Example I.D. #
Value
Enable definition 1
70
1
Use definition 1 to filter incoming data.
Symbology
71
C
Only Code 39 input will be edited.
Record length
72
00
The incoming data can contain any number of characters.
Number of fields
73
07
The incoming data contains seven fields.
Field 1
74
00(00)
The first field can be of any length and can begin with any character.
Field 2
75
01.
The second field is exactly one character long and that character is a period.
Parameter
56
Meaning
PowerWedge® 20 table
Page 63
Input Editing
Table 10. Parameter Settings for the Example Parameter
I.D. #
Value
Meaning
Field 3
76
00(00)
The third field can be of any length and can begin with any character.
Field 4
77
02.
The second field is exactly two characters long and the first character is a period.
Field 5
78
04(00)
The fifth field is exactly four characters long and can begin with any character.
Field 6
79
01.
The sixth field is exactly one character long and that character is a period.
Field 7
7A
00(00)
The seventh field can be of any length and can begin with any character.
If you are using the bar code batch programming method and the D2 predefined defaults, your bar codes for the definition should look like the following:
*$+$-70171C73077501.EE* *$+$-7702.7804%U7901.EE* Notice that the bar codes do not include settings for record length or for fields 1, 3, and 7. Since these parameters use the defaults, it is not necessary to include them in the bar codes. Also notice the %U in the second bar code. This is the Code 39 equivalent for the null character, which is used in place of 00 in bar code batch programming.
User’s Guide
57
Page 64
Input Editing
Step 2: Program Extra Fields Set parameters for three extra fields to contain the following: •
The I.D. badge reader’s location
•
A comma and a space to separate the first name from the last name
•
A tab to separate columns in the output
Table 11 lists the parameters and data strings you need to use. Each string ends with the end-of-string character (//). Table 11. Parameter Settings for the Extra Fields Parameter
I.D. #
String
Contents
Extra field 0
60
Area M//
The location of the I.D. badge reader
Extra field 1
61
, //
Extra field 2
62
(TABR)//
A comma followed by a space A tab character
Your bar codes for the extra-field settings should look like the following:
*$+$-60A+R+E+A!M//EE* *$+$-61/L!//62$I//EE* Notice the use of the plus symbols (+) before the R, the E, and the second A. These cause the letters to be output as lowercase (a, r, and e). In the second bar code, /L is the Code 39 equivalent for a comma, and $I is the Code 39 equivalent for a tab character. Also notice that each extra-field setting ends with an end-of-string character (//).
58
PowerWedge® 20
Page 65
Input Editing
Step 3: Program the Output Sequence Enter the following codes: 03610162056260B1// where 03 is field 3 (last name) 61 is extra field 1 (comma and space) 01 is field 1 (first name) 62 is extra field 2 (tab) 05 is field 5 (employee number without the leading 0) 62 is extra field 2 (tab) 60 is extra field 0 (“Area M”) B1 is the autoterminator (a carriage return) // is the end-of-string character
Your bar code for the output sequence should look like the following:
*$+$-7C03610162056260B1//EE* Once you’ve completed these steps, your new I.D. badge reader should be able to read the bar code on each employee’s badge and report that the employee has entered Area M.
User’s Guide
59