The text of a manual · part 7 of 20
VS1200 & HS1250 Programming Kit, pages 61 to 70
Pages 61 to 70 of 193
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC HS-1250 and Datalogic HS-1250
Page 61
EDGE™: DISABLE The Edge™ software only supports the UPC/EAN label set. If an industrial code (Code 39, Code 128, Code 93, Codabar, or Interleaved 2 of 5) is selected in addition to UPC/EAN, the Edge software will be automatically disabled and the Adaptive™ software will be enabled. The barcode label on this page can be used to disable Edge without enabling an industrial code. To re-enable the Edge software (and consequently disable industrial codes), you must use the Return to Default label on page four. Scanning this label will reset the scanner's configuration to the original factory settings. Scan this label to disable the ability to read torn or partially disfigured labels. Scanning this label automatically enables the Adaptive™ software which helps read marginless, overprinted and underprinted labels.
6 4 01 03 6 00 00 04 R44-1340
57
Page 62
UPC/EAN EXPANSION The labels on the following pages allow you to change the UPC/ EAN label transmission format.
UPC-E TO UPC-A EXPANSION – ENABLE Use this label to enable the ex-pansion of UPC-E labels to UPC-A format before transmission to the host terminal. Enabling this feature will automatically disable the 'Expand UPC-E to EAN-13' feature. The scanner will now translate UPC-E label data into UPC-A format before sending it to the host.
6 400065 000016 58
VS1200 & HS1250 Programming Kit
Page 63
UPC-E TO UPC-A EXPANSION – DISABLE Use this label to disable the expansion of UPC-E labels to UPC-A format before transmission to the host terminal. The scanner now sends UPC-E label data to the host.
6 400065 000009 R44-1340
59
Page 64
UPC-E TO EAN-13 EXPANSION – ENABLE Use this label to enable the expansion of UPC-E labels to EAN-13 format before transmission to the host terminal. Enabling this feature will automatically disable the 'Expand UPC-E to UPC-A' feature. The scanner will now translate UPC-E label data into EAN-13 format before sending it to the host.
6 401026 000014 60
VS1200 & HS1250 Programming Kit
Page 65
UPC-E TO EAN-13 EXPANSION – DISABLE Use this label to disable the expansion of UPC-E labels to EAN-13 format before transmission to the host terminal. The scanner will now send UPC-E label data to the host.
6 401026 000007 R44-1340
61
Page 66
UPC-A TO EAN-13 EXPANSION – ENABLE Use this label to enable the expansion of UPC-A labels to EAN-13 format before transmission to the host terminal. The scanner will now translate UPC-A label data into EAN-13 format before sending it to the host.
6 400067 000014 62
VS1200 & HS1250 Programming Kit
Page 67
UPC-A TO EAN-13 EXPANSION – DISABLE Use this label to disable the expansion of UPC-A labels to EAN-13 format before transmission to the host terminal. The scanner will now send UPC-A label data to the host.
6 400067 000007 R44-1340
63
Page 68
UPC CHECK DIGIT TRANSMISSION The following pages contain the programming labels for enabling and disabling the transmission of UPC and EAN check digits. NOTE These features DO NOT APPLY to the IBM 46xx interface. They are:
64
•
UPC-A Check Digit Transmission
•
UPC-E Check Digit Transmission
•
EAN-8 Check Digit Transmission
•
EAN-13 Check Digit Transmission
VS1200 & HS1250 Programming Kit
Page 69
UPC-A CHECK DIGIT TRANSMISSION: ENABLE Use this label to enable sending the UPC-A check digit to the host. NOTE This features DOES NOT APPLY to the IBM 46xx interface.
6 400183 000011 R44-1340
65
Page 70
UPC-A CHECK DIGIT TRANSMISSION: DISABLE Use this label to disable sending the UPC-A check digit to the host. NOTE This features DOES NOT APPLY to the IBM 46xx interface.
6 400183 000004 66