Page 71

UPC-E CHECK DIGIT TRANSMISSION: ENABLE Use this label to enable sending the UPC-E check digit to the host. NOTE This features DOES NOT APPLY to the IBM 46xx interface.

6 400064 000017 R44-1340

67

Page 72

UPC-E CHECK DIGIT TRANSMISSION: DISABLE Use this label to disable sending the UPC-E check digit to the host. NOTE This features DOES NOT APPLY to the IBM 46xx interface.

6 400064 000000 68

VS1200 & HS1250 Programming Kit

Page 73

EAN-8 CHECK DIGIT TRANSMISSION: ENABLE Use this label to enable sending the EAN-8 check digit to the host. NOTE This features DOES NOT APPLY to the IBM 46xx interface.

6 400184 000010 R44-1340

69

Page 74

EAN-8 CHECK DIGIT TRANSMISSION: DISABLE Use this label to disable sending the EAN-8 check digit to the host. NOTE This features DOES NOT APPLY to the IBM 46xx interface.

6 400184 000003 70

VS1200 & HS1250 Programming Kit

Page 75

EAN-13 CHECK DIGIT TRANSMISSION: ENABLE Use this label to enable sending the EAN-13 check digit to the host. NOTE This features DOES NOT APPLY to the IBM 46xx interface.

6 400185 000019 R44-1340

71

Page 76

EAN-13 CHECK DIGIT TRANSMISSION: DISABLE Use this label to disable sending the EAN-13 check digit to the host. NOTE This features DOES NOT APPLY to the IBM 46xx interface.

6 400185 000002 72

VS1200 & HS1250 Programming Kit

Page 77

CODE 39 The labels on the following pages allow you to enable or disable Code 39, select barcode content verification, choose whether or not to send the check digit to the host and set the minimum number of good reads required before the label data is sent to the host.

CODE 39: ENABLE Use this barcode to select Code 39 as an active symbology.

6 400142 000014 R44-1340

73

Page 78

CODE 39: DISABLE Use this barcode to disable Code 39 as an active symbology.

6 400142 000007 74

VS1200 & HS1250 Programming Kit

Page 79

CODE 39: CHECK DIGIT – VERIFY Use this barcode to enable Verify Code 39 check digit. Scanning this label tells the scanner to calculate the check digit and verify that it matches the barcodes internal check digit. The check digit will not be sent to the host unless you also enable Code 39: Check Digit - Send. Check your system interface communications requirements before changing this setting.

6 400085 000010 R44-1340

75

Page 80

CODE 39: CHECK DIGIT – DON'T VERIFY Using this barcode disables verification of the Code 39 check digit. If you disable this feature, you should also scan the label that disables sending the Code 39 Check Digit. Check your system interface communications requirements before changing this setting.

6 400085 000003 76

VS1200 & HS1250 Programming Kit