The text of a manual · part 6 of 20
VS1200 & HS1250 Programming Kit, pages 51 to 60
Pages 51 to 60 of 193
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC HS-1250 and Datalogic HS-1250
Page 51
DOUBLE READ TIMEOUT = 1 SECOND Sets the time you must wait between reading the same label twice to one second.
6 400077 001001 R44-1340
47
Page 52
PERIPHERAL PORT The VS1200 & HS1250 peripheral port can be configured to accept input from an undecoded handheld scanner. The labels on the following pages allow you to enable/disable the port, or change the communication speed.
HANDHELD PERIPHERAL PORT: ENABLE Use this label to enable the peripheral port to accept input from a handheld (HHLC) scanner.
6 401035 000005 48
VS1200 & HS1250 Programming Kit
Page 53
HANDHELD PERIPHERAL PORT: DISABLE Use this label to disable the peripheral port to accept input from a handheld (HHLC) scanner.
6 401035 000012 R44-1340
49
Page 54
HANDHELD PERIPHERIAL PORT SPEED Since the communication speed of handheld scanners vary greatly, it is necessary to select a speed that tells the VS1200 or HS1250 how long to wait to receive a complete barcode data. This selection process is rather unscientific (trial and error) since industry standards do not exist. We have included references for known and tested models of other manufacturers handheld scanners, but these should be considered as guidelines since newer and older models from the same manufacturer may be different. The selectable options are named speeds five through nine with five being used for scanners that communicate at a slow rate and nine for scanners that communicate at a faster rate.
50
VS1200 & HS1250 Programming Kit
Page 55
HANDHELD PERIPHERAL PORT: SPEED = 5 This label sets the communication speed to five. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data. This setting works best when connecting a Symbol Technology undecoded scanner to the peripherial port.
6 401067 000059 R44-1340
51
Page 56
HANDHELD PERIPHERAL PORT: SPEED = 6 This label sets the communication speed to six. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data.
6 401067 000066 52
VS1200 & HS1250 Programming Kit
Page 57
HANDHELD PERIPHERAL PORT: SPEED = 7 This label sets the communication speed to seven. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data. This is the default setting. Use this setting when connecting a SP400, Caere or PSC undecoded scanner.
6 401067 000073 R44-1340
53
Page 58
HANDHELD PERIPHERAL PORT: SPEED = 8 This label sets the communication speed to eight. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data.
6 401067 000080 54
VS1200 & HS1250 Programming Kit
Page 59
HANDHELD PERIPHERAL PORT: SPEED = 9 This label sets the communication speed to nine. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data.
6 401067 000097 R44-1340
55
Page 60
CHANGING BARCODE TYPES One of the scanner's features is the ability to autodiscriminate between the UPC/EAN symbology family and one industrial codes; Code 39, Interleaved 2 of 5, Code 128, Codabar or Code 93. The following barcodes allow you to change the types of barcode symbologies that your scanner recognizes. Be sure that your POS terminal interface can recognize the barcodes you wish to enable before you change these settings. To change symbologies: 1. Select the symbology you wish to enable. (e.g. Code 39) 2. Scan the appropriate programming barcode label that enables the selected symbology. 3. Enable all additional parameters that are required by your POS terminal (e.g. check digits, start/stop characters, etc). All of the symbology selection features on the following pages can be used to customize the VS1200 or HS1250 scanner.
56
VS1200 & HS1250 Programming Kit