Page 51

DOUBLE READ TIMEOUT = 1 SECOND Sets the time you must wait between reading the same label twice to one second.

6 400077 001001 R44-1340

47

Page 52

PERIPHERAL PORT The VS1200 & HS1250 peripheral port can be configured to accept input from an undecoded handheld scanner. The labels on the following pages allow you to enable/disable the port, or change the communication speed.

HANDHELD PERIPHERAL PORT: ENABLE Use this label to enable the peripheral port to accept input from a handheld (HHLC) scanner.

6 401035 000005 48

VS1200 & HS1250 Programming Kit

Page 53

HANDHELD PERIPHERAL PORT: DISABLE Use this label to disable the peripheral port to accept input from a handheld (HHLC) scanner.

6 401035 000012 R44-1340

49

Page 54

HANDHELD PERIPHERIAL PORT SPEED Since the communication speed of handheld scanners vary greatly, it is necessary to select a speed that tells the VS1200 or HS1250 how long to wait to receive a complete barcode data. This selection process is rather unscientific (trial and error) since industry standards do not exist. We have included references for known and tested models of other manufacturers handheld scanners, but these should be considered as guidelines since newer and older models from the same manufacturer may be different. The selectable options are named speeds five through nine with five being used for scanners that communicate at a slow rate and nine for scanners that communicate at a faster rate.

50

VS1200 & HS1250 Programming Kit

Page 55

HANDHELD PERIPHERAL PORT: SPEED = 5 This label sets the communication speed to five. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data. This setting works best when connecting a Symbol Technology undecoded scanner to the peripherial port.

6 401067 000059 R44-1340

51

Page 56

HANDHELD PERIPHERAL PORT: SPEED = 6 This label sets the communication speed to six. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data.

6 401067 000066 52

VS1200 & HS1250 Programming Kit

Page 57

HANDHELD PERIPHERAL PORT: SPEED = 7 This label sets the communication speed to seven. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data. This is the default setting. Use this setting when connecting a SP400, Caere or PSC undecoded scanner.

6 401067 000073 R44-1340

53

Page 58

HANDHELD PERIPHERAL PORT: SPEED = 8 This label sets the communication speed to eight. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data.

6 401067 000080 54

VS1200 & HS1250 Programming Kit

Page 59

HANDHELD PERIPHERAL PORT: SPEED = 9 This label sets the communication speed to nine. Use Peripherial Port Speed settings to tell the scanner how long to wait to receive a complete barcode data.

6 401067 000097 R44-1340

55

Page 60

CHANGING BARCODE TYPES One of the scanner's features is the ability to autodiscriminate between the UPC/EAN symbology family and one industrial codes; Code 39, Interleaved 2 of 5, Code 128, Codabar or Code 93. The following barcodes allow you to change the types of barcode symbologies that your scanner recognizes. Be sure that your POS terminal interface can recognize the barcodes you wish to enable before you change these settings. To change symbologies: 1. Select the symbology you wish to enable. (e.g. Code 39) 2. Scan the appropriate programming barcode label that enables the selected symbology. 3. Enable all additional parameters that are required by your POS terminal (e.g. check digits, start/stop characters, etc). All of the symbology selection features on the following pages can be used to customize the VS1200 or HS1250 scanner.

56

VS1200 & HS1250 Programming Kit