Page 51
LOCAL FORMATTING can be a literal string such as GR, a formatted data string or a combination of the two. See Data Formatting Codes page 5-17. HOST NO READ XMIT FORMAT - This entry determines what data is transmitted from the Host Port if a No Read condition occurs. This is usually a message string saying that there is no bar code label to transmit. See Data Formatting Codes page 5-17. LOCAL NO READ XMIT FORMAT - This entry determines what data is transmitted from the Local Port if a No Read condition occurs. This is usually a message string saying that there is no bar code label to transmit. See Data Formatting Codes page 5-17. HOST READ CONFLICT XMIT FORMAT - This entry determines what data is transmitted from the Host Port if a Read Conflict occurs. A Read Conflict occurs when the bar codes read on a particular package exceeds the number of Field Definitions that have been entered. See Data Formatting Codes page 5-17. LOCAL READ CONFLICT XMIT FORMAT - This entry determines what data is transmitted from the Local Port if a Read Conflict occurs. A Read Conflict occurs when the bar codes read on a particular package exceeds the number of Field Definitions that have been entered. See Data Formatting Codes page 5-17. LABEL MASK - This entry allows the user to define which fields the decoded labels are inserted into. Five labels per field can be specified. LABEL MASK EXAMPLES: Label: "123456" Label Mask String: 123* 123 match up so we have a good compare. Label: "123456" Label Mask String: 1?3?5? 1,3,5 match up so we have a good compare. * - ignores all characters from that point on in the bar code. ? - ignores the character in that position in the bar code.
5-15
Page 52
Series 9000E Scanner/Decoder Operator Actions: 1.
With the cursor at the first CODE TYPE line, use the DOWN ARROW key to select the desired line. Press the SPACE BAR to review the code types available. When the correct choice is displayed, press ENTER to move to the XMIT S/S line.
2.
With the cursor on the XMIT S/S line use the SPACE BAR to toggle between the choices, YES and NO. When the desired choice is displayed, press ENTER to make the selection and move to the next line.
3.
With the cursor on the XMIT CHK DGT line use the SPACE BAR to toggle between the YES and NO choices. Press ENTER to select the appropriate choice and move to the next field.
4.
With the cursor positioned on the LENGTH line, enter the number of characters in the code to be read including any check characters and start/stop characters if enabled. Entering a zero will cause any length to be read.
5.
With the cursor positioned on the READ COUNTS line, enter the number of times the label must be read before it will be transmitted.
6.
When all the desired code types have been entered, use the DOWN ARROW key to position the cursor next to the HOST GOOD READ XMIT FORMAT line. This is the first of six entries that format the Local and Host ports for the Good Read, No Read and Read Conflict conditions.
7.
With the cursor positioned on the LABEL MASK line enter the characters for the label mask string. This string will accept the * and ? qualifiers. When the * is used everything from the asterisk till the end of the letter is ignored. When the ? is used, the positions selected are ignored.
DATA FORMATTING CODES: The two types of entries are data formatting and literal formatting.
5-16
Page 53
LOCAL FORMATTING Data formatting information is always bracketed by % and controls how the bar code data is transmitted. Data formatting information only applies to the current field. Different fields can have different data formatting. The % symbol is used as a format place holder (any characters not bracketed by % will transmit as literal messages). D is label data. It indicates label data should be transmitted. C is read count (how many times a label is seen on a package). It indicates read count data should be transmitted. Any string following this command must be preceded by a %. N, S, and Z control fill characters. N = not fill, S = fill with spaces, and Z = fill with zeros. R, L, and M select right (or right justified), left (or left justified), or middle (midstring characters). The entry for M is two numbers with a comma between them. For example, an entry of 3,7 would mean that with a string of eight characters such as 12345678 or ABCDEFGH the selection would start at the third character (3 or C) and end with the seventh character (7 or G). For example, %DZR6% and %DR6% both mean transmit right six characters. In the event that the data is passed on to a system (e.g. a main frame computer) with a standard format of greater than six characters, %DZR6% would be used and the blank spaces filled with zeros. %DR6% would be used when the string is shorter than the bar code.
DATA FORMATTING CODES EXAMPLES: Example bar code: "012345678" Format Control %D% %DR6%
Output "012345678" "345678" 5-17
Page 54
Series 9000E Scanner/Decoder %DL6% %DM2,6% %DZR11% %DSL11%
"012345" "12345" "00012345678" "012345678__" (the label followed by two spaces)
Literal formatting information is transmitted from the port exactly as entered. Literal messages have a maximum length of sixty characters. %D% will send the message out to the port exactly like it was decoded.
HOST PORT PARAMETERS SCREEN
COM HARDWARE PROTOCOL: RS 232 COM BAUD RATE: 9600 COM PARITY: NONE COM DATA BITS: EIGHT COM STOP BITS: ONE RTS/CTS FLOW CONTROL: NO COM SOFTWARE PROTOCOL: NONE COM ECHO/PASS-THROUGH: NO_ECHO TRANSMIT ON ANY NO READ: TRANSMIT ON ALL NOREADS: TRANSMIT ALGORITHM ID: TRANSMIT READ DIRECTION:
YES YES NO NO
START OF MESSAGE STRING: END OF MESSAGE STRING: <CR><LF> GOOD COMPARE STRING: GC NO COMPARE STRING: NC SCANNER ID STRING: FIELD DELIMETER STRING: + INTERCHARACTER DELAY: 0 (0 - 999 msec) KEYS: SPACE=TOGGLE+ BKSPACE=TOGGLE- <CTRL-U>=LAST SCREEN
PAGE 3 - HOST PORT FORMATTING Purpose of Screen: Allows the user to set the data transfer parameters between the Series 9000E Bar Code Scanner/Decoder and the host computer available through the Host Port. 5-18
Page 55
LOCAL FORMATTING
Allows the user to format the data string which is sent from Series 9000E Bar Code Scanner/Decoder to the host computer when a bar code is read.
5-19
Page 56
Series 9000E Scanner/Decoder Field Descriptions: COM HARDWARE PROTOCOL - Allows choice of one of three hardware protocols: RS-232, RS-422, RS-485 2 wire*, RS-485 4 wire*. * intended to be used with LazerData Multidrop only COM BAUD RATE - The baud rate can be set using any of the following values: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400. COM PARITY - Parity for this port can be set to none, even or odd. If set to none there is no parity bit in the transmission. COM DATA BITS - The number of data bits per character can be 7 or 8. COM STOP BITS - The number of stop bits per character can be 1 or 2. RTS/CTS FLOW CONTROL - This controls whether the RTS and CTS handshake signals will be used for RS-232 or RS-422. COM SOFTWARE PROTOCOL - Software protocols may be specified if desired. If NONE is chosen, no software protocol will be used. Other choices are: ACK/NAK (ACK/NAK Timeout is explained on page 5-9), XON/XOFF (short cut keys are CTRL Q and CTRL S, respectively), INTERMEC and LazerData MULTI-DROP. COM ECHO/PASS THROUGH - Each transmission received on this port can be echoed (repeated) to another port. The choices are NO ECHO, HOST, LOCAL, or BOTH. Selecting NO ECHO will not echo any transmission. Selecting HOST will re-transmit the input signal on this port to the output on this port. Selecting LOCAL will echo the input signal on this port to the output on the local port. Selecting BOTH will echo the input signal on this port to the output on both ports. TRANSMIT ON ANY NOREAD - User can determine whether a data transmission will (YES) or will not (NO) be made when a No Read condition occurs in ANY field.
5-20
Page 57
LOCAL FORMATTING TRANSMIT ON ALL NOREADS - User can determine whether a data transmission will (YES) or will not (NO) be made when a No Read condition occurs in ALL fields. TRANSMIT ON ANY NOREAD must be set to YES. TRANSMIT ON NO COMPARE - User can determine whether a data transmission will (YES) or will not (NO) be made when a No Compare condition occurs. TRANSMIT ALGORITHM ID - User can determine if the Algorithm ID will be part of the serial transmission. Will not transmit when multiple fields have been selected. TRANSMIT READ DIRECTION - User can determine if direction of bar code read (FWD = Forward, REV = Reverse) is transmitted. Will not transmit when multiple fields have been selected. START OF MESSAGE STRING - User may select any character string to signify the beginning of each data transmission. The length can be up to 10 characters. If control characters are included they must be bracketed, < >. For example: <STX>. END OF MESSAGE STRING - User may select a string of characters to signify the end of each data transmission. The length can be up to 10 characters. Default string is <CR><LF> (carriage return, line feed). GOOD COMPARE STRING - User may select a string of characters to be transmitted to signify a Good Compare. Default is GC. Maximum length is 60 characters. NO COMPARE STRING - User may select a string of characters to be transmitted to signify No Compare. Default is NC. Maximum length is 60 characters. SCANNER ID STRING - User may select a character string to identify the scanner sending the message. In an installation with multiple decoders connected to a host, this identification string may be necessary. Maximum length is 10 characters.
5-21
Page 58
Series 9000E Scanner/Decoder FIELD DELIMITER STRING - When data for more than one bar code is sent during a single transmission, a character or string of characters is specified that separates the bar code data fields. This occurs if more than one bar code label is on a single package. Default character is "+". Control characters must be bracketed, < >. Maximum length is 2 characters. INTERCHARACTER DELAY - Sets the delay between every character sent to the port. Operator Action: 1.
With the cursor positioned at the end of the HARDWARE PROTOCOL line press SPACE to step through the choices. When the desired choice is displayed press ENTER to enter it and proceed to the next line.
2
With the cursor set to the BAUD RATE line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.
3.
With the cursor set to the PARITY line press SPACE to step through the choices, ODD, EVEN or NONE. When the desired choice is displayed press ENTER to select it and move to the next line.
4.
With the cursor set to the DATA BITS line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.
5.
With the cursor set to the STOP BITS line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.
6.
With the cursor set to the RTS/CTS FLOW CONTROL line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.
7.
With the cursor set to the SOFTWARE PROTOCOL line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.
5-22
Page 59
LOCAL FORMATTING 8.
With the cursor set to the ECHO/PASS-THROUGH line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.
9.
With the cursor positioned on the TRANSMIT ON ANY NO READ line press SPACE to select YES or NO. When the desired choice is displayed press ENTER to select it and move to the next line.
10. With the cursor positioned on the TRANSMIT ON ALL NO READS line press SPACE to select YES or NO. When the desired choice is displayed press ENTER to select it and move to the next line. 11. With the cursor positioned on the TRANSMIT ALGORITHM ID line press SPACE to select YES or NO. When the desired choice is displayed press ENTER to select it and move to the next line. 12. With the cursor positioned on the TRANSMIT READ DIRECTION line press SPACE to select YES or NO. When the desired choice is displayed press ENTER to select it and move to the next line. Note: The BACK SPACE or DEL keys can be used to edit information entered on the following lines.
13. With the cursor positioned on the START OF MESSAGE STRING LINE type the message start string. Control characters must be enclosed in < >. 14. With the cursor positioned on the END OF MESSAGE STRING Line type in the message end string. Press ENTER to select new string and move cursor to the next line. Control characters must be enclosed in < >. Press ENTER to select default, <CR><LF>. 15. With the cursor positioned on the GOOD COMPARE STRING line type in the Good Compare message. To accept the default (GC), press ENTER. 16. With the cursor positioned on the NO COMPARE STRING line type in the No Compare message. To accept the default (NC), press ENTER.
5-23
Page 60
Series 9000E Scanner/Decoder 17. With the cursor positioned on the SCANNER ID STRING line type in the character string used to identify the scanner. Press ENTER to select the string and move the cursor to the next line. 18. With the cursor positioned on the FIELD DELIMITER line type in the character string used. Press ENTER to select the new string and move the cursor to the next line. Control characters must be enclosed in < >. Press ENTER to select default, "+". 19. With the cursor positioned on the INTERCHARACTER DELAY line type in the value in milliseconds of the delay. Value must be between 0 and 999 msec.
5-24