Page 61

LOCAL FORMATTING

LOCAL PORT PARAMETERS SCREEN

COM HARDWARE PROTOCOL: RS 232 COM BAUD RATE: 9600 COM PARITY: NONE COM DATA BITS: EIGHT COM STOP BITS: ONE COM SOFTWARE PROTOCOL: NONE COM ECHO/PASS-THROUGH: NO_ECHO

TRANSMIT ON ANY NO READ: TRANSMIT ON ALL NOREADS: TRANSMIT ALGORITHM ID: TRANSMIT READ DIRECTION:

YES YES NO NO

START OF MESSAGE STRING: END OF MESSAGE STRING: <CR><LF> GOOD COMPARE STRING: GC NO COMPARE STRING: NC SCANNER ID STRING: FIELD DELIMETER STRING: + INTERCHARACTER DELAY: 0 (0 - 999 msec) KEYS: SPACE=TOGGLE+ BKSPACE=TOGGLE- <CTRL-U>=LAST SCREEN

PAGE 4 - LOCAL PORT FORMATTING Purpose of Screen: Allows the user to set the data transfer parameters for the Local Port. Allows the user to format the data string for the Local Port. Field Descriptions: COM HARDWARE PROTOCOL - Hardware protocol is set to RS-232. COM BAUD RATE - The baud rate can be set using any of the following values: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400. COM PARITY - Parity for this port can be set to none, even or odd. If set to none there is no parity bit in the transmission. 5-25

Page 62

Series 9000E Scanner/Decoder COM DATA BITS - The number of data bits per character can be 7 or 8. COM STOP BITS - The number of stop bits per character can be 1 or 2. COM SOFTWARE PROTOCOL - Software protocols may be specified if desired. Choices are NONE or XON/XOFF. COM ECHO/PASS THROUGH - Each transmission received on this port can be echoed (repeated) to another port. The choices are NO ECHO, HOST, LOCAL, or BOTH. Selecting NO ECHO will not echo any transmission. Selecting HOST will re-transmit the input signal on this port to the output on the HOST port. Selecting LOCAL will echo the input signal on this port to the output on the local port. Selecting BOTH will echo the input signal on this port to the output on both ports. TRANSMIT ON ANY NOREAD - User can determine whether a data transmission will (YES) or will not (NO) be made when a No Read condition occurs in ANY field. GOOD READ BASED ON must be set to “ALL FIELDS”. TRANSMIT ON ALL NO READS - User can determine whether a data transmission will (YES) or will not (NO) be made when a No Read condition occurs in ALL fields. TRANSMIT ON ANY NOREAD must be set to YES. TRANSMIT ON NO COMPARE - User can determine whether a data transmission will (YES) or will not (NO) be made when a No Compare condition occurs. TRANSMIT ALGORITHM ID - User can determine if the Algorithm ID will be part of the serial transmission. Will not transmit when multiple fields have been selected. TRANSMIT READ DIRECTION - User can determine if direction of bar code read (F = Forward, R = Reverse) is transmitted. Will not transmit when multiple fields have been selected. START OF MESSAGE STRING - User may select any character string to signify the beginning of each data transmission. The length can be up to 10 characters. If control characters are included they must be bracketed, < >.

5-26

Page 63

LOCAL FORMATTING END OF MESSAGE STRING - User may select a string of characters to signify the end of each data transmission. Default string is <CR><LF> (carriage return, line feed). Maximum length is 10 characters. GOOD COMPARE STRING - User may select a string of characters to be transmitted to signify a Good Compare. Default is GC. Maximum length is 60 characters. NO COMPARE STRING - User may select a string of characters to be transmitted to signify No Compare. Default is NC. Maximum length is 60 characters. SCANNER ID STRING - User may select a character string to identify the scanner sending the message. In an installation with multiple decoders connected to a host, this identification string may be necessary. Maximum length is 10 characters. FIELD DELIMITER STRING - When data for more than one bar code is sent during a single transmission, a character or string of characters is specified that separates the bar code data fields. This occurs if more than one bar code label is on a single package. Default character is "+". Control characters must be bracketed, < >. Maximum length is two characters. INTERCHARACTER DELAY - Sets the delay between every character sent to the port.

Operator Action: 1.

2.

With the cursor set to the BAUD RATE line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line. With the cursor set to the PARITY line press SPACE to step through the choices, ODD, EVEN or NONE. When the desired choice is displayed press ENTER to select it and move to the next line.

5-27

Page 64

Series 9000E Scanner/Decoder 3.

With the cursor set to the DATA BITS line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.

4.

With the cursor set to the STOP BITS line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.

5.

With the cursor set to the RTS/CTS FLOW CONTROL line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.

6.

With the cursor set to the SOFTWARE PROTOCOL line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.

7.

With the cursor set to the ECHO/PASS-THROUGH line press SPACE to step through the choices. When the desired choice is displayed press ENTER to select it and move to the next line.

8.

With the cursor positioned on the TRANSMIT ON ANY NO READ line press SPACE to select YES or NO. When the desired choice is displayed press ENTER to select it and move to the next line.

9.

With the cursor positioned on the TRANSMIT ON ALL NO READS line press SPACE to select YES or NO. When the desired choice is displayed press ENTER to select it and move to the next line.

10. With the cursor positioned on the TRANSMIT ALGORITHM ID line press SPACE to select YES or NO. When the desired choice is displayed press ENTER to select it and move to the next line. 11. With the cursor positioned on the TRANSMIT READ DIRECTION line press SPACE to select YES or NO. When the desired choice is displayed press ENTER to select it and move to the next line. Note:

The BACK SPACE or DEL keys can be used to edit information entered on the following lines.

12. With the cursor positioned on the START OF MESSAGE STRING Line type the message start string. Control characters must be enclosed in < >. 5-28

Page 65

LOCAL FORMATTING

13. With the cursor positioned on the END OF MESSAGE STRING Line type in the message end string. Press ENTER to select new string and move cursor to the next line. Control characters must be enclosed in < >. Press ENTER to select default, <CR><LF>. 14. With the cursor positioned on the GOOD COMPARE STRING line type in the Good Compare message. To accept the default (GC), press ENTER. 15. With the cursor positioned on the NO COMPARE STRING line type in the No Compare message. To accept the default (NC), press ENTER. 16. With the cursor positioned on the SCANNER ID STRING line type in the character string used to identify the scanner. When the message is typed in press ENTER to enter the string and move the cursor to the next line. 17. FIELD DELIMITER - With the cursor positioned on the FIELD DELIMITER line type in the character string used. Press ENTER to select the new string and move the cursor to the next line. Control characters must be enclosed in < >. Press ENTER to select default, "+". 18. With the cursor positioned on the INTERCHARACTER DELAY line type in the value in milliseconds of the delay. Value must be between 0 and 999 msec.

5-29

Page 66

Series 9000E Scanner/Decoder INPUT/OUTPUT PULSE PARAMETERS SCREEN

OUTPUT #1 GOOD-READ: (0-9999 msec) OUTPUT #2 NO-READ: (0-9999 msec) OUTPUT #3 GOOD-COMPARE: (0-9999 msec) OUTPUT #4 NO-COMPARE: (0-9999 msec)

10 msec 10 msec 10 msec 10 msec

OUTPUT PULSES ARE ACTIVE WHEN: LOW GATE INPUT IS ACTIVE WHEN: LOW GOOD READ BASED ON: ALL FIELDS TRANSMIT NOCOMPARE ON NOREAD: YES

KEYS: UP DOWN LEFT RIGHT BACKSPACE DEL <CTRL-U>=LAST SCREEN

PAGE 5 - OUTPUT PULSE CONFIGURATION Purpose of Screen: This screen enables the user to select output pulse duration’s for various read conditions. Duration’s up to 9999 milliseconds are possible. Field Descriptions: GOOD READ - The duration of the output pulse that occurs on a Good Read condition can be programmed. Values up to 9999 milliseconds may be entered. NO READ - The duration of the output pulse that occurs on a No Read condition can be programmed. Values up to 9999 milliseconds may be entered.

5-30

Page 67

LOCAL FORMATTING GOOD COMPARE - The duration of the output pulse that occurs on a Good Compare condition can be programmed. Values up to 9999 milliseconds may be entered. NO COMPARE - The duration of the output pulse that occurs on a No Compare condition can be programmed. Values up to 9999 milliseconds may be entered. OUTPUTS ARE ACTIVE - Outputs can be made active high or active low. An active high output would normally be low (logic 0) and go high (logic 1) when activated. An active low output is the opposite. GATE INPUT IS ACTIVE - Gate input can be made active high or active low. An active high gate input would normally be low (logic 0) and go high (logic 1) when activated. An active low gate input is the opposite. GOOD READ BASED ON - When multiple fields are used this entry line defines the criteria for Good Read Pulse Output.

a

All Fields - Every code type for each field must be identified for Good Read Pulse. This is the default condition. First Field - Good Read pulse asserted if first field contains data. Any Field - Good Read pulse asserted if any field contains data.

TRANSMIT NOCOMPARE ON NOREAD - This option will allow the user greater control over the No Compare output pulse. If YES is selected the output of scanner will be one of the following: bar code GC text GR pulse GC pulse bar code NC text GR pulse NC pulse NR NC text NR pulse NC pulse

5-31

Page 68

Series 9000E Scanner/Decoder If NO is selected the output of scanner will be one of the following: bar code GC text GR pulse GC pulse bar code NC text GR pulse NC pulse NR No NC text NR pulse no NC pulse If formatting is modified the Good Read Text will appear before or after the bar code. Operator Action: 1.

With the cursor positioned at the end of the GOOD READ line type in the desired duration in milliseconds. Press ENTER to select this value and move to the next line.

2.

With the cursor positioned at the end of the NO READ line type in the desired duration in milliseconds. Press ENTER to select this value and move to the next line.

3.

With the cursor positioned at the end of the GOOD COMPARE line type in the desired duration in milliseconds. Press ENTER to select this value and move to the next line.

4.

With the cursor positioned at the end of the NO COMPARE line type in the desired duration in milliseconds. Press ENTER to select this value and move to the next line.

5.

With the cursor positioned at the end of the OUTPUTS ARE ACTIVE line use SPACE to display the choices; High or Low. When the desired condition is displayed, press ENTER to select this condition and move to the next line.

6.

With the cursor positioned at the end of the GATE INPUT IS ACTIVE line use SPACE to display the choices; High or Low. When the desired condition is displayed, press ENTER to select this condition and move to the next line.

7.

With the cursor positioned at the end of the GOOD READ BASED ON line use SPACE to display the choices; All Fields, First Field, or Any Field. Press ENTER to select.

5-32

Page 69

LOCAL FORMATTING 8.

With the cursor positioned at the end of the TRANSMIT NOCOMPARE ON NOREAD line use SPACE to display the choices; YES or NO. When the desired condition is displayed press ENTER to select this condition and move to the next line.

5-33

Page 70

Series 9000E Scanner/Decoder CONFIGURATION SAVE/DEFAULT SCREEN

SAVE CONFIGURATION: NO DEFAULT CONFIGURATION: NO

LAZERDATA MODEL: LD9000E REVISION: 2.00 Date: August 23, 1995

KEYS: SPACE=TOGGLE+ BKSPACE=TOGGLE- <CTRL-U>=LAST SCREEN

PAGE 6 - SAVE DATA BASE CONFIGURATION Purpose of Screen: This screen enables the user to save a new configuration or load the default data base configuration. Field Descriptions: SAVE CONFIGURATION - Saves current user configuration. DEFAULT CONFIGURATION - Loads the factory default configuration but does not automatically save. If scanner is powered down prior to saving the DEFAULT CONFIGURATION the scanner will return to its previously saved configuration. Returns terminal type to 1 (“DEC VT100, ANSI, LCDOS”). Operator Action: 5-34