The text of a manual · part 9 of 12
User's / Programming Guide, Handheld Laser Bar Code Scanners, Keyboard Wedge / Wand Emulation Interface: Message Formatting, pages 58 to 66
Pages 58 to 66 of 84, from User's / Programming Guide, Handheld Laser Bar Code Scanners, Keyboard Wedge / Wand Emulation Interface
The original document is the PDF (680 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the PSC 5381
Page 58
UD
Enable Full ASCII Code 93
UE
Set Minimum Length, specified by two digits 0-1-32
UA
Disable Code 93
16K TF
Enable 16K Code
TE
Disable 16K Code
52
User’s / Programming Guide
Page 59
0
1 2 3
4
Digit Selection
5
MM 6
MAMET 7
UU 8
UU 9
06656
53
Page 60
Symbology Identifiers Your PSC scanner can be programmed to add and/or change symbology identifiers which might be required to be transmitted with messages. This feature is provided to allow a host computer to recognize the type of bar code scanned, as well as the uncoded information. The symbology identifiers are selected by scanning the desired programming bar code symbol as defined below. SYMBOL
FUNCTION
FA
Disable Transmission of Symbology Identifiers*
FB
Enable Transmission of Symbology Identifiers
FE
Set UPC-A Symbology Identifier
FF
Set UPC-E Symbology Identifier
FG
Set EAN-8 Symbology Identifier
FH
Set EAN-13 Symbology Identifier
FI
Set Code 128 Symbology Identifier
54
User’s / Programming Guide
Page 61
FJ
Set Code 39 Symbology Identifier
FK
Set I 2/5 Symbology Identifier
FL
Set S 2/5 Symbology Identifier
FM
Set Code 11 Symbology Identifier
FN
Set Code 93 Symbology Identifier
FO
Set Codabar Symbology Identifier
FP
Set MSI/Plessey Symbology Identifier
To change any single symbology identifier, scan the appropriate symbology identifier bar code symbol and then scan the four hexadecimal characters that represent the two bytes of the identifier. If you select a one character identifier, then scan zero (null) twice for the second character.
06656
55
Page 62
To find the hexadecimal values for the characters turn to the Hexadecimal Conversion Table. The procedure for selecting a symbology identifier is identical to the procedure for selecting Preambles and Postambles. The similar difference is that symbology identifiers are a maximum of two characters, not four.
NOTE
Scanning the ZA (Result to Default) programming symbol will set all symbology identifiers back to PSC defaults as given in Table I and disable the transmission of the symbology identifiers.
The FC programming symbol selects the symbology identifiers for use with ICL 9518/9520 cash registers. FC
Programming Symbol
The FD programming symbol selects the symbology identifiers for use with ICL 9518/9520 cash registers as given in Table 5. FD
56
Programming Symbol
User’s / Programming Guide
Page 63
Table 5. Symbology Identifiers ZA-PSC Default
PC-ICL 9518
CCD
UPC-A
G
$
$
UPC-E
G
(
&
EAN-8
G
))
%
EAN-13
G
)
$
Code 128
I
,
<
Code 39
D
,
<
Interleaved 2/5
E
,
=
Standard 2/5
F
,
<
Code 11
H
,
<
Code 93
J
,
<
Codabar (NW7)
K
,
;
MSI/Plessey
S
,
<
Symbology
06656
57
Page 64
Wand Emulation Parameters Select Code Type Scan Option CC if you intend to operate the scanner in Same Code Wand Emulation mode. If you want the label to be transmitted in Code 39 scan Option CB. CC
Same Code Wand # Emulation
CB
Wand Emulation (Code 39, Full ASCII)
Bar Code Polarity Selected Option WA or WB. WA
Black High#
WB
White High
WC
Black High, Quiescent High
Transmission Rate Select the fastest speed your decoder will accept for best overall performance by scanning one of the following labels. YA
58
5 inches per second
User’s / Programming Guide
Page 65
YB
10 inches per second#
YC
15 inches per second
YD
20 inches per second
YE
30 inches per second
YF
50 inches per second
YG
70 inches per second
06656
59
Page 66
Data Synchronization Your PSC scanner can be prepared to synchronize the transmission of scanned data to the timing sequence some terminals require to properly receive the data. This relationship is diagrammed in Figure 2. Figure 2. Timing Sequence Diagram
Data Transmission
(ta)
data white space
Active
(th)
Data Synchronization
Setup Time (ts) 200 ms - 220 ms Hold Time (th) 0 ms - 10 ms
RTS output is used for the data synchronization signal. Scan XD to enable the data synchronization signal. Scan Option XC to disable Data Synchronization. XC
Disable Data # Synchronization
XD
Enable Data Synchronization
Polarity may be selected as either active high or low by scanning XE (high) or XF (low).
60
User’s / Programming Guide