The text of a manual · part 8 of 12
User's / Programming Guide, Handheld Laser Bar Code Scanners, Keyboard Wedge / Wand Emulation Interface: Message Formatting, pages 49 to 57
Pages 49 to 57 of 84, from User's / Programming Guide, Handheld Laser Bar Code Scanners, Keyboard Wedge / Wand Emulation Interface
The original document is the PDF (680 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the PSC 5381
Page 49
Transmission of the last character in an EAN/JAN symbol (the check digit) is disabled by scanning Option RF, or is enabled by scanning Option RG.
RF
Disable Transmission of Check Digit
RG
Enable Transmission of Check Digit *#@
RJ
Disable EAN-8 Transmission of check character
RK
Enable EAN-8 Transmission of check character*
RL
Disable EAN-8 Transmission of number system digit
RM
Enable EAN-8 Transmission of number system digit*
RN
Disable EAN-8 independently*
RO
Enable EAN-8 independently with supplement
RP
Enable EAN-8 independently without supplement
06656
43
Page 50
RQ
Disable EAN-8 special 5 character (0’s) preamble
RR
Enable EAN-8 special 5 character (0’s) preamble
RA to RG apply to both EAN-13 and EAN-8. NOTE
Code 39 To disable Code 39, scan Option OA. OA
Disable Code 39
To enable Code 39, scan Option OB or OC. After enabling Code 39, make any additional required selections from Options OD through OG. OB
Enable St6andard Code 39*#@
OC
Enable Full ASCII Code 39
OD
Disable Modulo 43 Check Character*#@
OE
Enable Modulo 43 Check Character
44
User’s / Programming Guide
Page 51
The minimum length of Code 39 messages is set by scanning Option OH, followed by scanning two digits (01-32) from the Digit Selection page.
OH
Minimum Length (specified by two digits 01-32)
The maximum length of Code 39 messages is set by scanning Option OI, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read.
OI
Maximum Length (specified by two digits 01-32)
The START and STOP characters in code 39 may either be transmitted or suppressed. Scan Option OF to suppress transmission of the START and STOP characters. Scan Option OG to enable transmission. OF
Do Not XMIT START and STOP*#@
OG
Transmit START and STOP
The following are only valid if CHK CHAR is enabled.
OJ
Enable Transmission of Code 39 Modulo 43 Check Character
OK
Disable Transmission of Code 39 Modulo 43 Check Character *
06656
45
Page 52
Code 2 of 5 – Interleaved Scan Option PA to disable Interleaved Code 2 of 5.
PA
Disable Interleaved Code 2 of 5*#@
Scan Option PB or PC to enable Interleaved Code 2 of 5.
PB
Enable Interleaved 2 of 5 without Check Digit
PC
Enable Interleaved 2 of 5 with Check Digit
The minimum length of Interleaved 2 of 5 messages is set by scanning Option PD, followed by scanning two digits (02-32) from the Digit Selection page. The value of the number you scan must be even.
PD
Minimum Length I 2 of 5 (specified by two digits 02-32)
The maximum length of Interleaved Code 2 of 5 is set by scanning Option PE, followed by scanning two digits (02-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read. The minimum and maximum lengths must be even numbers.
PE
Maximum Length I 2 of 5 (specified by two digits 02-32)
46
User’s / Programming Guide
Page 53
Code 2 of 5 – Standard Scan Option PF to disable Standard Code 2 of 5. PF
Disable Standard Code 2 of 5 *#@
Scan Option PG to enable Standard Code 2 of 5. PG
Enable Standard 2 of 5
The minimum length of Standard 2 of 5 messages is set by scanning Option PH, followed by scanning two digits (01-32) from the Digit Selection page.
PH
Minimum Length S 2 of 5 (specified by two digits 01-32)
The maximum length is set by scanning Option PI, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read. The minimum and maximum lengths must be even numbers. PI
Maximum Length S 2 of 5
The following are only valid if CHK CHAR is enabled. PO
Disable I 2/5 check character
PP
Enable I 2/5 check character
06656
47
Page 54
Code 128 Scan Option TA to disable Code 128. TA
Disable Code 128
Scan Option TB to enable Code 128. TB
Enable Code 128 *#@
The minimum length of Code 128 messages is set by scanning Option TC, followed by scanning two digits (01-32) from the Digit Selection page.
TC
Minimum Length (specified by two digits 01-32)
The maximum length of Code 128 messages is set by scanning Option TD, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read.
TD
Maximum Length (specified by two digits 01-32) Codabar
Scan Option VA to disable Codabar.
VA
Disable Codabar *#@
Scan Option VB to enable Codabar. VB
48
Enable Codabar
User’s / Programming Guide
Page 55
The minimum length of Codabar messages is set by scanning Option VE, followed by scanning two digits (01-32) from the Digit Selection page.
VE
Minimum Length (specified by two digits 01-32)
The maximum length of Codabar messages is set by scanning Option VF, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read.
VF
Maximum Length (specified by two digits 0-32)
The transmission of the STOP/START Characters is enabled by scanning Option VD, or is suppressed by scanning Option VC.
VC
Disable Transmission *#@ of START/STOP character
VD
Enable Transmission of START/ STOP Character
06656
49
Page 56
MSI/Plessey Previous customization of other scanner features may have made MSI/Plessey unavailable in some scanners. Consult Customer Service for current capabilities or if you require a specific symbology.
PK
Enable MSI/PLESSEY
PL
Set Minimum Length, then scan two digits: 01-14 (see Digit Selection).
PM
Set Maximum Length, then scan two digits: 01-14 (see Digit Selection).
PJ
Disable MSI/PLESSEY
Code 11 Previous customization of other scanner features may have made Code 11 unavailable in some scanners. Consult Customer Service for current capabilities or if you require a specific symbology.
SB
Enable Code 11 with one check digit
SC
Enable Code 11 with two check digits
50
User’s / Programming Guide
Page 57
SF
Set Minimum Length, specified by two digits 01-32
SG
Set Maximum Length, specified by two digits 01-32
SE
Enable transmission of check digits
SD
Disable transmission of check digits
SA
Disable Code 11
Code 93 Previous customization of other scanner features may have made Code 93 unavailable in some scanners. Consult Customer Service for current capabilities or if you require a specific symbology.
UB
Enable Code 93
UC
Standard Code 93
06656
51