Page 49

Transmission of the last character in an EAN/JAN symbol (the check digit) is disabled by scanning Option RF, or is enabled by scanning Option RG.

RF

Disable Transmission of Check Digit

RG

Enable Transmission of Check Digit *#@

RJ

Disable EAN-8 Transmission of check character

RK

Enable EAN-8 Transmission of check character*

RL

Disable EAN-8 Transmission of number system digit

RM

Enable EAN-8 Transmission of number system digit*

RN

Disable EAN-8 independently*

RO

Enable EAN-8 independently with supplement

RP

Enable EAN-8 independently without supplement

06656

43

Page 50

RQ

Disable EAN-8 special 5 character (0’s) preamble

RR

Enable EAN-8 special 5 character (0’s) preamble

RA to RG apply to both EAN-13 and EAN-8. NOTE

Code 39 To disable Code 39, scan Option OA. OA

Disable Code 39

To enable Code 39, scan Option OB or OC. After enabling Code 39, make any additional required selections from Options OD through OG. OB

Enable St6andard Code 39*#@

OC

Enable Full ASCII Code 39

OD

Disable Modulo 43 Check Character*#@

OE

Enable Modulo 43 Check Character

44

User’s / Programming Guide

Page 51

The minimum length of Code 39 messages is set by scanning Option OH, followed by scanning two digits (01-32) from the Digit Selection page.

OH

Minimum Length (specified by two digits 01-32)

The maximum length of Code 39 messages is set by scanning Option OI, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read.

OI

Maximum Length (specified by two digits 01-32)

The START and STOP characters in code 39 may either be transmitted or suppressed. Scan Option OF to suppress transmission of the START and STOP characters. Scan Option OG to enable transmission. OF

Do Not XMIT START and STOP*#@

OG

Transmit START and STOP

The following are only valid if CHK CHAR is enabled.

OJ

Enable Transmission of Code 39 Modulo 43 Check Character

OK

Disable Transmission of Code 39 Modulo 43 Check Character *

06656

45

Page 52

Code 2 of 5 – Interleaved Scan Option PA to disable Interleaved Code 2 of 5.

PA

Disable Interleaved Code 2 of 5*#@

Scan Option PB or PC to enable Interleaved Code 2 of 5.

PB

Enable Interleaved 2 of 5 without Check Digit

PC

Enable Interleaved 2 of 5 with Check Digit

The minimum length of Interleaved 2 of 5 messages is set by scanning Option PD, followed by scanning two digits (02-32) from the Digit Selection page. The value of the number you scan must be even.

PD

Minimum Length I 2 of 5 (specified by two digits 02-32)

The maximum length of Interleaved Code 2 of 5 is set by scanning Option PE, followed by scanning two digits (02-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read. The minimum and maximum lengths must be even numbers.

PE

Maximum Length I 2 of 5 (specified by two digits 02-32)

46

User’s / Programming Guide

Page 53

Code 2 of 5 – Standard Scan Option PF to disable Standard Code 2 of 5. PF

Disable Standard Code 2 of 5 *#@

Scan Option PG to enable Standard Code 2 of 5. PG

Enable Standard 2 of 5

The minimum length of Standard 2 of 5 messages is set by scanning Option PH, followed by scanning two digits (01-32) from the Digit Selection page.

PH

Minimum Length S 2 of 5 (specified by two digits 01-32)

The maximum length is set by scanning Option PI, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read. The minimum and maximum lengths must be even numbers. PI

Maximum Length S 2 of 5

The following are only valid if CHK CHAR is enabled. PO

Disable I 2/5 check character

PP

Enable I 2/5 check character

06656

47

Page 54

Code 128 Scan Option TA to disable Code 128. TA

Disable Code 128

Scan Option TB to enable Code 128. TB

Enable Code 128 *#@

The minimum length of Code 128 messages is set by scanning Option TC, followed by scanning two digits (01-32) from the Digit Selection page.

TC

Minimum Length (specified by two digits 01-32)

The maximum length of Code 128 messages is set by scanning Option TD, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read.

TD

Maximum Length (specified by two digits 01-32) Codabar

Scan Option VA to disable Codabar.

VA

Disable Codabar *#@

Scan Option VB to enable Codabar. VB

48

Enable Codabar

User’s / Programming Guide

Page 55

The minimum length of Codabar messages is set by scanning Option VE, followed by scanning two digits (01-32) from the Digit Selection page.

VE

Minimum Length (specified by two digits 01-32)

The maximum length of Codabar messages is set by scanning Option VF, followed by scanning two digits (01-32) from the Digit Selection page. If the minimum and maximum values are set equal, only codes of that exact length are read.

VF

Maximum Length (specified by two digits 0-32)

The transmission of the STOP/START Characters is enabled by scanning Option VD, or is suppressed by scanning Option VC.

VC

Disable Transmission *#@ of START/STOP character

VD

Enable Transmission of START/ STOP Character

06656

49

Page 56

MSI/Plessey Previous customization of other scanner features may have made MSI/Plessey unavailable in some scanners. Consult Customer Service for current capabilities or if you require a specific symbology.

PK

Enable MSI/PLESSEY

PL

Set Minimum Length, then scan two digits: 01-14 (see Digit Selection).

PM

Set Maximum Length, then scan two digits: 01-14 (see Digit Selection).

PJ

Disable MSI/PLESSEY

Code 11 Previous customization of other scanner features may have made Code 11 unavailable in some scanners. Consult Customer Service for current capabilities or if you require a specific symbology.

SB

Enable Code 11 with one check digit

SC

Enable Code 11 with two check digits

50

User’s / Programming Guide

Page 57

SF

Set Minimum Length, specified by two digits 01-32

SG

Set Maximum Length, specified by two digits 01-32

SE

Enable transmission of check digits

SD

Disable transmission of check digits

SA

Disable Code 11

Code 93 Previous customization of other scanner features may have made Code 93 unavailable in some scanners. Consult Customer Service for current capabilities or if you require a specific symbology.

UB

Enable Code 93

UC

Standard Code 93

06656