Page 40

Keyboard Wedge Parameters Scan symbol CE to enable Keyboard Wedge mode. Next, select a terminal type by scanning the symbol CF for IBM PC-AT or PS/2 models 50/60/80; or symbol CG for PC-XT type terminals. Alternatively, you may scan just CF or CG to enable wedge mode and select a terminal type.

CE

Wedge Mode Enable @

ZA

Reset to Wedge Default Values

CF

PC-AT, PS/2 and 50/60/80@, U.S.A.

CG

PC-XT – U.S.A.

CH

IBM 3151 – U.S.A.

CI

DEC VT220 – U.S.A.

CN

Macintosh

CP

IBM 3477 – U.S.A.

34

User’s / Programming Guide

Page 41

CT

IBM 319X – U.S.A.

CY

PS/2 Mode 57/25, U.S.A.

C6

Unisys B-26

C8

Link 125

CV

PC-AT German Keyboard

CW

PC-AT French Keyboard

CX

PC-AT UK Keyboard

\B

PC-AT Belgian Keyboard

\C

PC-AT Swiss Keyboard

\D

PC-AT Danish Keyboard

06656

35

Page 42

\E

PC-AT Italian Keyboard

\F

PC-AT Spanish Keyboard

\G

PC-AT Swedish Keyboard

\H

PC-AT Portuguese Keyboard

\L

DEC VT 220/320/420 German Keyboard

\M

DEC VT 220/320/420 French Keyboard

In normal Wedge Mode, the scanner emulates the keyboard exactly. Should a scanned bar code label have alphabetic characters, they will be presented to the computer as if they had been typed at the keyboard. They will be affected by the Caps Lock key. If the scanned label has lower case alphabetic characters AND the Caps Lock key in ON, then the alphabetics will be presented as upper case. With the Caps Lock key ON, the user may required that the scanned alphabetics are presented to the computer exactly as they are encoded in the label. This is accomplished by scanning EO – Shift Alphabetic Characters.

36

User’s / Programming Guide

Page 43

EO

Shift Alphabetic Characters

EP

Normal Alphabetic Characters*

NOTE

In some models of scanner, the wedge output is capable of two types. To enable primary or secondary keyboard modes, scan one of the next two labels.

CQ

Enable Primary Keyboard@

CR

Enable Secondary Keyboard

NOTE

In Wedge Mode, non-printable ASCII characters (00-31H) do not allow for an obvious translation to keycodes. There are two approaches to this issue – they are explained in Appendix A.

@Q

Enable Primary Function Key Table@

@R

Enable Secondary Function Key Table

See Appendix A. NOTE

06656

37

Page 44

Symbologies The PSC scanner is configured with Code 39, Code 128, UPC-A and UPC-E not expanded symbologies. The user has the ability to enable or disable any of the symbologies given below as well as UPC or EAN supplements, I 2 of 5 with check digit, and Code 39 modulo 43 check digit. The bar codes that can be read by PSC’s bar code scanners include: Code 39

Code 93

Interleaved 2 of 5

Code 128

Standard 2 of 5

Codabar

UPC-A, UPC-E

Code 11

EAN/JAN

MSI/Plessey

The minimum label lengths are set to 1 character, except Code I 2 of 5, which is set to 14 characters; andCode S 2 of 5, which is set to 4 characters. The maximum label length for all symbologies is set to 32 characters. The user has the ability to set the minimum and maximum label lengths. The symbol * indicates Default Parameter for serial mode. The symbol # indicates Default Parameters for Wand Emulation. The symbol @ indicates default parameters for Wedge Mode. It is recommended that the user disable those symbologies and parameters that are not being used. NOTE

UPC (A and E) Scan Option QA to disable all UPC labels. QA

38

Disable UPC (both A and E)

User’s / Programming Guide

Page 45

Option QB or Option QC enable both UPC-A and UPC-E. If UPC is enabled, any UPC label, with or without supplement, is read. The supplement is read if Option QB is selected, and it is ignored if Option QC is selected.

QB

Enable UPC with 2 or 5 Digit Supplement Enabled

QC

Enable UPC with 2 or 5 Digit Supplement Disabled *#@

Expanded UPC-E is disabled by scanning Option QH, or is enabled by scanning Option QI.

QH

Disable Expanded UPC-E *#@

QI

Enable Expanded UPC-E

Transmission of the first character in a UPC symbol (the number system character) is disabled by scanning Option QD or enabled by scanning Option QE.

QD

Disable Transmission of Number System Digit

QE

Enable Transmission of Number System Digit *#@

06656

39

Page 46

Transmission of the last character in a UPC symbol (the check digit) is disabled by scanning Option QF, or is enabled by scanning Option QG.

QF

Disable Transmission of Check Digit

QG

Enable Transmission of Check Digit *#

Scanning QJ causes UPC-A labels to be transmitted as EAN-13 labels. Scanning QK disables this feature. QJ

Enable UPC to EAN Translation

QK

Disable UPC to EAN Translation *#@

QN

Disable second beep on Supplement decoded *

QO

Enable second beep on Supplement decoded

QP

Set supplement retry count (16 by default) range = 1-32

QR

Disable transmissionof UPC-E check digit

40

User’s / Programming Guide

Page 47

QS

Enable transmissionof UPC-E check digit*

QT

Disable transmission of UPC-E number system digit

QU

Enable transmission of UPC-E number system digit

QV

Disable UPC-E*

QW

Enable UPC-E independently with supplement

QX

Enable UPC-E independently without supplement*

Q0

Disable mandatory supplements*

Q1

Enable mandatory supplements

QA to QG apply to UPC-A and UPC-E. NOTE

06656

41

Page 48

EAN/JAN Scan Option RA to disable EAN/JAN (8 or 13 digit).

RA

Disable EAN/JAN (8 or 13 Digit) #@

Option RB or RC enables both EAN 8 digit and EAN 13 digit. If EAN/JAN is enabled, any EAN/JAN label, with or without supplement, is read. The supplement is read if Option RB is selected and is ignored if Option RC is selected.

RB

Enable EAN/JAN with 2 or 5 Digit Supplement enabled

RC

Enable EAN/JAN with 2 or 5 Digit *Supplement disabled

Transmission of the first character in an EAN/JAN symbol (the number system character) is disabled by scanning Option RD, or is enabled by scanning Option RE.

RD

Disable Transmission of Number System Digit

RE

Enable Transmission of Number System Digit *#@