The text of a manual · part 10 of 12
User's / Programming Guide, Handheld Laser Bar Code Scanners, Keyboard Wedge / Wand Emulation Interface: Message Formatting, pages 67 to 71
Pages 67 to 71 of 84, from User's / Programming Guide, Handheld Laser Bar Code Scanners, Keyboard Wedge / Wand Emulation Interface
The original document is the PDF (680 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the PSC 5381
Page 67
XE
Active # Polarity High
XF
Active Polarity Low
06656
61
Page 68
Memory Module The Memory Module option is a factory installed feature that is requested at time of order. The Memory Module option allows the 5300 series scanner to store decoded labels in an internal battery backed up RAM. The stored buffered labels can then be transmitted some time later. The user may also choose an interlabel transmission delay in cases where the transmission rate of the buffered decoded label is faster than the receiving equipment. Switching to the Memory Module mode is achieved by scanning the Enable Memory Module symbol. The Memory Module is cleared every time Memory Module is enabled. While in Memory Module mode, the scanner will store in its internal memory all scanned bar code labels. The user can transmit the stored labels by scanning the Send Memory Module symbol. When the transmission rate is faster than the receiving equipment, the user can program a delay that will occur after each label. The delay is programmed by scanning the Interlabel Delay symbol (see the Intercharacter Delay page of the Setup Parameters section), followed by two digits (see Digit Selection page) to set the delay duration. The allowable range of values is 00 to 99, where 99 corresponds to a delay of 9.9 seconds. In order to restore the scanner to normal operation, the user needs to scan the Disable Memory Module label. Also the user may clear the contents of the Memory Module by scanning the Clear Memory Module symbol or by disabling and enabling Memory Module. Stored labels are cleared whenever Memory Module is enabled. The stored data in the Memory Module cannot be transmitted through the Wand Emulation output. NOTE
CAUTION
62
The Memory Module feature is to be used only with the Memory Module mode. When used with scanners without this optional mode, programmed instructions will be damaged.
User’s / Programming Guide
Page 69
Setup NC
Disable Memory Module*#
ND
Enable Memory Module
MM
Enable automatic switch to memory module
MN
Disable automatic switch to memory module *
If enabled, this mode intelligently switches from POS mode to Memory Module mode based on power source. NOTE
ZK
Send Memory Module
ZL
Clear Memory Module
06656
63
Page 70
Marker Beam The Marker Beam feature provides the user with a spotter beam for improved aiming at distant bar code labels and/or in extremely bright environments. You may also find a Marker Beam useful when scanning through showcase glass or bar code menus with labels in close proximity. This feature is available in all scanners without factory authorization. To activate the Marker Beam, the user must also program the duration of the Marker Beam. First, the symbol Enable Marker Beam is scanned and then followed by scanning one digit symbol from the Digit Selections table. Each digit symbol represents the desired time duration of the Marker Beam in milliseconds. To deactivate the Marker Beam, the user must scan the Disable Marker Beam symbol. For successful programming, the user must hold the trigger down for two seconds after scanning. NQ
Enable Marker Beam
NP
Disable Marker Beam
64
User’s / Programming Guide
Page 71
300 ms
50 MS
350 MS
100 MS
400 MS
150 MS
450 MS
200 MS
500 MS
250 MS
06656