For the PSC 16000

Page 37

LazerData® 16000 Scanner

Installation Manual

CLOUTGNDCL CLOUT+ DRVIN CLINDRVOUT CLIN+

16000 SCANNER

USER INTERFACE

I = 20 mA V

DRVOUT

R C.L. OUT+ P

C.L. OUT-

N

CLGND

U

DRVIN

SGND

I = 20 mA T C.L. IN+ S

C.L. IN-

GND MAX. 300 METERS

Figure 2.21 - 20-mA C.L. active connections 16000 SCANNER

USER INTERFACE +

T C.L. IN+ S

C.L. IN-

+ R C.L. OUT+ P

C.L. OUT-

MAX. 300 METERS

Figure 2.22 - 20-mA C.L. passive connections

2.22 - Installation

Page 38

LazerData® 16000 Scanner

Installation Manual

2.6.3

Auxiliary interface

The auxiliary serial interface is equipped with both RS232 and RS485-polled interface connections. The interface type is exclusive and is selectable through the LDHOST configuration program. For the RS232 auxiliary interface only RXA and TXA pins are used. The following pins of the 19-pin connector are used: Pin J L N K M V

Name RXA TXA DGND AUX485 + AUX485 GNDRS485

Function Auxiliary input Auxiliary output Ground Auxiliary interface Auxiliary interface RS485 Ground Reference 485GND TXD 485+ RXD

16000 SCANNER

USER INTERFACE

J

RXA

L

TXA

N

DGND

TXD RXD GND

Figure 2.23 - RS232 Auxiliary interface connections

Installation - 2.23

Page 39

LazerData® 16000 Scanner

Installation Manual

16000 SCANNER

USER INTERFACE

K

AUX485+

M

AUX485-

V

GNDRS485

RXTX+ RXTXGND

Figure 2.24 - RS485 Auxiliary interface connections

NOTE RS485-polled interface cannot be selected as auxiliary interface if the main interface is 20-mA CL.

2.6.4

Inputs

The inputs of the scanner are on the 6-pin circular connector (Figure B, 14 ) on the body of the scanner. These inputs are called ENC, PS1 and PS2. ENC is the Encoder input. In PackTrack™ mode, it detects the conveyor speed. PS1 is the main presence sensor. When active, this input tells the scanner to scan for a code and that decoding can take place. The yellow LED (Figure A, 9 ) indicates the PS1 is active. PS2 can be used as the stop signal for the reading phase. All inputs are optocoupled and driven by a constant current generator; the command signal is filtered through an anti-disturbance circuit which generates a delay of about 5 ms for PS1 and PS2 and 500 µs for ENC. For PS1 and PS2, the NPN or PNP connection must be made by setting the jumper as shown in section 2.3.3.

2.24 - Installation

Page 40

LazerData® 16000 Scanner

Installation Manual

16000 SCANNER

+ 5V

Vext A

VS

D/C

PS1+/PS2+

B

SGND

PRESENCE SENSOR V

PSIN

Figure 2.25 - Presence sensor input PNP command Vext

16000 SCANNER + 5V

A

VS

D/C

PS1-/PS2-

B

SGND

PRESENCE SENSOR V

PSIN

Figure 2.26 - Presence sensor input NPN command

16000 SCANNER

ENCODER A

VS

E

ENC+

F

ENC-

B

SGND

V

+ 5V

Ground

Signal

Figure 2.27 - Encoder NPN input command using scanner power 16000 SCANNER

Vext

ENCODER

+ 5V E

ENC+

F

ENC-

V

Signal

Figure 2.28 - Encoder NPN input command using external power

Installation - 2.25

Page 41

LazerData® 16000 Scanner

Installation Manual

16000 SCANNER

ENCODER A

VS

E

ENC+

F

ENC-

B

SGND

+ 5V

Figure 2.29 - Encoder PNP input command using scanner power 16000 SCANNER

Vext

ENCODER V

+ 5V E

ENC+

F

ENC-

Signal

Figure 2.30 - Encoder PNP input command using external power

Isolation between the command logic and the scanner is maintained by powering the inputs with a different supply voltage (Vext) from that supplied on the 6-pin connector (VS). The driving logic of the input signals may be powered, for convenience, with the voltage supply between pins A (VS) and B (SGND) of the connector. In this case, however, the device is no longer electrically isolated. The voltage available on the input connector, between pins A and B, is physically the same as used to power the scanner. The electrical features of these inputs are: Maximum voltage

30 V

Maximum current

25 mA

2.26 - Installation

Page 42

LazerData® 16000 Scanner

Installation Manual

2.6.5

Outputs

Apart from the main and auxiliary interface outputs on the 19-pin circular connector (Figure B, 12 ), there are also indicator and power supply outputs for external devices. Pin A B C D E F G H

Name SGND VS NO READNO READ+ RIGHTRIGHT+ I.U. I.U.

Function Power for external devices (Negative pin) Power for external devices (Positive pin) No read output No read output Right code output Right code output Internal use Internal use

A D.C. output voltage, the same as that powering the scanner, is present between pins A and B. This may be used to power external devices: electrical isolation between the scanner and external devices is lost in this case. The NO READ output activates when a code signaled by the presence sensor is not decoded. The RIGHT output is used to signal the presence of a right code, thus a good decode condition. The NO READ and RIGHT outputs are all level- or pulse-programmable: a 50-ms pulse is generated in the second case. Further programming information is supplied in the LDHOST Help File. These outputs are created using optoisolated Darlington drivers and supply both the collector and emitter in output, allowing both loads referenced to ground and to the power supply to be driven. The electrical features are given below: Collector-emitter voltage

30 V Max.

Collector current

130 mA Max.

Saturation voltage (VCE)

1 V at 10 mA Max.

Maximum power dissipation

90 mW at 50°C/122ºF (Ambient temperature).

Installation - 2.27

Page 43

LazerData® 16000 Scanner

Installation Manual

USER INTERFACE

16000 SCANNER

Vext 30 Vdc max

D/F

NO READ+ RIGHT+

C/E

NO READRIGHT-

Figure 2.31 - Output interface

When the load is powered by an external power supply, the voltage must be less than 30 V. The limit requested by the maximum power dissipation is more important than that of the maximum collector current: if one of these outputs is continuously driven, the maximum current must not be more than 40 mA, although 130 mA may be reached in pulse conditions.

2.7

POSITIONING

The LazerData 16000 Scanner is able to decode moving bar code labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the scanner, take into consideration these three ideal label-position angles: Pitch 0°, Skew 10° to 30° and Tilt 0°. Follow the suggestions for the best orientation: The Pitch angle is represented by the value P in Figure 2.32. Position the reader in order to minimize the Pitch angle. P

Figure 2.32 - "Pitch" angle

2.28 - Installation

Page 44

LazerData® 16000 Scanner

Installation Manual

The Skew angle is represented by the value S in Figure 2.33. Position the reader to assure at least 10° for the Skew angle. This avoids the direct reflection of the laser light emitted by the scanner.

S

Figure 2.33 - "Skew" angle

The Tilt angle is represented by the value T in Figure 2.34. For code reconstruction, see section 3.1.1. T

Figure 2.34 - Tilt angle

!

2.8

FOCUS ADJUSTMENT

Before installing the scanner, select a specific reading area by means of the optical system for manual adjustment of the focal length. The focus adjustment is obtained by rotating a regulation screw that moves the internal lenses and therefore causes the laser beam focusing position to change. Seven marks, numbered from 0 to 6, are printed on the regulation screw to indicate the different positions of the internal optics. The diagram in section 3.3 shows the reading performance that can be obtained from 16000 Scanners when operating with different focus positions and bar code label densities.

Installation - 2.29

Page 45

LazerData® 16000 Scanner

Installation Manual

Even though the screw is marked with seven positions, the focus adjustment is continuous and not by step; this allows an optimum adjustment around the selected position.

WARNING Disconnect the scanner from the power supply during this operation to avoid exposure to hazardous visible laser light.

Refer to the following instructions when adjusting the focus: 1) Unscrew the focus regulation cover (Figure A,

3

) near the laser output win- dow for access to the focus adjustment screw. 2) Carefully turn the screw counterclockwise until the number 0 is aligned with the notch as shown in the following figure. 3) Now turn the focus adjustment screw clockwise to reach the desired position (refer to the reading diagrams in section 3.3).

Figure 2.35 - Focus regulation

NOTE The focus adjustment screw is positioned by default at the value 2.

2.30 - Installation