The text of a manual · part 6 of 7
LazerData 16000 Series Bar Code Scanner Installation Manual, pages 46 to 54
Pages 46 to 54 of 62
The original document is the PDF (705 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC 16000
Page 46
LazerData® 16000 Scanner
Installation Manual
2.9
TYPICAL LAYOUTS
A photoelectric sensor, used as a code presence sensor, signals to activate the scanner when a code symbol enters the scanner reading zone.
2.9.1
Standard layout
For Standard layout selections, the main serial interface can be selected for RS232, RS485-nonpolled, or 20-mA C.L. communications.
Host
1
2
1
Main serial interface
2
Presence sensor
Figure 2.36 - Standard layout
Standard with Local Echo Using a Local Echo layout, the data is transmitted on the Auxiliary interface as well as on the Main interface. RS485-polled communications cannot be used on either interface in this layout. Programming in Host Mode can also be accomplished through the Auxiliary interface using a Local Echo layout. Terminal
2 1
Host
3
1
Main serial interface
2
Auxiliary serial interface
3
Presence sensor
Figure 2.37 - Standard with Local Echo layout
Installation - 2.31
Page 47
LazerData® 16000 Scanner
2.9.2
Installation Manual
Master-Slave layout
The master-slave connection is used to collect data from several scanners to build either an omnidirectional or a multisided reading system; there can be one master and up to eight slaves connected with the RS485-polled mode on the auxiliary serial interface. The master scanner is also connected to either a Host or a Multiplexer on the main serial interface. The possible main interface connections are RS232 or RS485nonpolled for Host connections or RS485-polled for Multiplexer connections. (See “Main Interface Selection in section. 2.3.1). For the slave scanners the Multidrop Address Selection must be different from zero and consecutive. (See "Multidrop Address Selection" in section 2.3.2).
NOTE The termination resistors of the RS485 bus must not be installed.
Single Presence Sensor The presence sensor signal is unique to the system; there is a single reading phase and a single message from the master scanner to the Host. 16000 Slave Scanner
1
MULTIPLEXER RS485-polled
2 16000 Slave Scanner HOST PC or PLC RS232 RS485-nonpolled
3
16000 Master Scanner
1 Main serial interface 2 Auxiliary serial interface: RS485-polled 3 Presence sensor Figure 2.38 - Master-slave single presence sensor layout
2.32 - Installation
Page 48
LazerData® 16000 Scanner
Installation Manual
Multiple Presence Sensors In this layout, each scanner has its own presence sensor and therefore multiple reading phases. The master sends the individual messages collected from the multidrop line as well as its own to the Host. 16000 Master Scanner
2
MULTIPLEXER
2
16000 Slave Scanner
RS485-polled
1 HOST PC or PLC
3
3
RS232 RS485-nonpolled
1 Main serial interface 2 Auxiliary serial interface: RS485-polled 3 Presence sensor Figure 2.39 – Multiple presence sensor layout connections
2.9.3
Multiplexer layout
Each scanner is connected to a Multiplexer with the RS485-polled mode on either the main or the auxiliary interface. The other interface is not used. 32
2
1
MULTIPLEXER
Host
P.S.
P.S.
P.S.
Figure 2.40 - Multiplexer layout
Installation - 2.33
Page 49
LazerData® 16000 Scanner
2.9.4
Installation Manual
Omnidirectional reading
Two or more scanners are correctly positioned in a master-slave single presence sensor layout to compose an omnidirectional reading station. This layout is used only with code reconstruction decoding mode. P.S. PHOTOCELL
16000 SCANNER READING AREA code motion
16000 SCANNER
Figure 2.41 - Omnidirectional reading
2.34 - Installation
Page 50
LazerData® 16000 Scanner
Installation Manual
3.
READING FEATURES
3.1
CODE RECONSTRUCTION
The traditional way of bar code reading could be called "Linear Reading". In linear reading, the laser beam crosses the bar code symbol from its beginning to its end as shown in Figure 3.1.
Laser Beam Figure 3.1 - Linear reading
In CODE RECONSTRUCTION mode it is no longer necessary for the laser beam to cross the label from the start to the end. With just a set of partial scans on the label (obtained using the motion of the label itself), the scanner is able to "reconstruct" the bar code. A typical set of partial scans is shown in Figure 3.2.
Code Direction Figure 3.2 - Partial scans
None of the partial scans contains the whole label. The decoder aligns each partial scan correctly and combines them in order to obtain the entire code. The alignment is performed by calculating the time difference from one partial scan to another using a reference code element.
3.1.1
The tilt angle for code reconstruction
The most important parameter in Code Reconstruction is the value of the maximum tilt angle (α maximum) under which the code reconstruction process is still possible. We define the Tilt angle as the angle α between the laser beam and a line parallel to the bar code label, as shown in Figure 3.3.
Reading Features - 3.1
Page 51
LazerData® 16000 Scanner
Installation Manual
Laser Beam 0° to α max
α = tilt angle
α Figure 3.3 - Tilt angle
The formulas to calculate α maximum depend on various factors such as label height, number of scans per second, code motion speed, etc. To obtain α maximum for your application, please contact your PSC Automation representative. You must remember that the decoder will be able to read the label with a tilt angle between + α max and - α max as shown in Figure 3.4 (the shaded zones are the NO READ zones). 0°
−α +α
Laser Beam
Figure 3.4 - Reading zones with a max
3.2
PERFORMANCE
It is possible to change the focus of the LazerData 16000 Scanner in order to reach the reading distance expected. The scan rate is 800 scans/s. Refer to the diagrams in section 3.3 for further details on the reading features. These diagrams are taken on various resolution sample codes at a 25 °C (77ºF) ambient temperature depending on the conditions listed in table 3.1. If standard models do not satisfy specific requirements, you can supply representative code samples to your nearest PSC Automation distributor to obtain complete information on the reading possibilities.
3.2 - Reading Features
Page 52
LazerData® 16000 Scanner
Installation Manual
3.3
READING DIAGRAMS
The diagrams on the following pages show the reading distance for bar codes with different densities and refer to two laser beam apertures. The following table illustrates the convention used for reading diagrams and the operating conditions of the scanners that refer to these measures: C B
CONDITIONS Code
= Interleaved 2/5 or Code 39
PCS
= 0.90
"Pitch" angle
= 0°
"Skew" angle
= 10°
"Tilt" angle
= 0°
A
D
30° 50°
50° 30°
A = minimum reading distance
Operating mode
= linear
B = maximum reading distance at 50° aperture C = maximum reading distance at 30° aperture D = laser beam aperture
Table 3.1 - Reading diagram conventions and operating conditions
F =0
30° aperture angle 50° aperture angle
F =2
12 mil
F =4 F =0 20 mil
F =4 F =6 F =0 F =6
39 mil
F = 6* 0
10
* Long Range Adjustment
20
30
40
50
60
70
Reading Distance (inches)
Figure 3.5 - Reading distances for the LazerData 16000 Scanner
Reading Features - 3.3
Page 53
LazerData® 16000 Scanner
Installation Manual
Example: The following figure shows the reading diagram obtained for the LazerData 16000 Scanner operating with focus screw set at position 6 and bar code density of 20 mil. From figure 3.5 you will get the following reading distances: Minimum Maximum at 50° of laser beam aperture Maximum at 30° of laser beam aperture
= 17.7 in. = 41.3 in. = 49.2 in.
Note: (0,0) is the center of the laser beam output window 40
30
20
10
0
10
20
30
40 0
10
20
30
40
50
60
70
Figure 3.6 - Example of reading diagram for the LazerData 16000 Scanner
3.4 - Reading Features inches
Page 54
LazerData® 16000 Scanner
Installation Manual
20
15
10
5
0
5
10
15
20 0
5
10
15
20
25
30
35 inches
Figure 3.7 - Empty grid for the scanner: reading distance from 0 to 40 inches
Reading Features - 3.5