Page 28

LazerData® 16000 Scanner

Installation Manual

Rubber seal

J1

Scanner cable

Figure 2.12 - Scanner cable connections to the junction box

5) Close the junction box using the four cover screws making sure the rubber seal is fitted correctly between the housing parts. The JBOX is now installed. The electrical connections for your scanning system are complete. If it ever becomes necessary to disconnect the scanner from the JBOX, simply reverse the procedure in step four.

Installation - 2.13

Page 29

LazerData® 16000 Scanner

2.6

Installation Manual

ELECTRICAL CONNECTIONS

The LazerData 16000 Scanner is available with two different electrical connection systems: Junction box model The scanner is equipped with a cable that connects it to the junction box. The junction box (JBOX) houses spring-clamp terminal blocks for the connections to the power supply and the input/output signals (refer to section 2.5). Connector model The scanner is equipped with four connectors for the following signals: • Power supply

(male, 3 pins)

(Figure B, 13 )

• Presence sensors

(female, 6 pins)

(Figure B, 14 )

• Output/Serial interfaces (female, 19 pins)

(Figure B, 12 )

• Oscillating mirror

(Figure B, 15 )

(female, 2 pins)

Power supply connector

SGND TO 16000 SCANNER CHASSIS VS (10 to 30 VDC) Figure 2.13 - Power supply connector

Pin A B C

2.14 - Installation

Name SGND VS CHASSIS

Power supply pinout Function Signal Ground Supply voltage Chassis Ground

Page 30

LazerData® 16000 Scanner

Installation Manual

Input connector VS

SGND ENC-

ENC+

PS2+/-

PS1+/Figure 2.14 - Input connector

Pin A B C D E F

Input pinout Function Power for external devices (Positive pin) Power for external devices (Negative pin) Presence sensor 2 Presence sensor 1 Encoder (Positive pin) Encoder (Negative pin)

Name VS SGND PS2+/PS1+/ENC+ ENC-

Oscillating mirror connector

1 2

VS1

SGND

Figure 2.15 - Oscillating mirror connector

Pin 1 2

Name VS1 SGND

Oscillating mirror pinout Function Supply voltage (output) (Positive pin) Supply voltage (output) (Negative pin)

This output passes the operating power supply voltage from the scanner to the oscillating mirror. It is physically the same as the input power supplied to the scanner.

Installation - 2.15

Page 31

LazerData® 16000 Scanner

Installation Manual

Output/Serial interface connector (A) SGND (B) VS

(N) DGND

(M) AUX485(L) TXA (K) AUX485+ (J) RXA

(C) NO READ(D) NO READ+ (E) RIGHT-

(H) I.U.

(F) RIGHT+

(G) I.U.

(P) (R) (S) (T) (U)(V) P1 P2 P3 P4 P5 P6

Figure 2.16 - Output/Serial interface connector

Pin A B C D E F G H J K L M N *P *R *S *T *U *V

Output/Serial interface pinout Name Function SGND Supply voltage (Negative pin) VS Supply voltage (Positive pin) NO READNo read output NO READ+ No read output RIGHTRight code output RIGHT+ Right code output I.U. Internal use I.U. Internal use RXA Auxiliary serial interface AUX485 + (see section 2.6.3) TXA AUX485 DGND Digital ground P1 *Main serial interface P2 (see section 2.6.2) P3 P4 P5 P6

*The function of the pins depends on the interface selected.

2.16 - Installation

Page 32

LazerData® 16000 Scanner

Installation Manual

2.6.1

Power supply

The supply voltage for correct operation of the scanner must be between 10 and 30 VDC. The max. power consumption is 9 W. The power block (optional), supplies the power necessary for the scanner and allows main power to be used. A security system allows the laser to activate only once the motor has reached the correct rotational speed; consequently, the laser beam is generated after a slight delay from when the scanner is powered up.

2.6.2

Main serial interface

The main serial interface is compatible with the following electrical standards: EIA RS232 EIA RS485-nonpolled EIA RS485-polled 20-mA current loop The configuration parameters of the selected interface can be defined using one of the programming methods available. For this procedure refer to the Help Online shipped on the LDHOST configuration disk. The connections and possibility of use regarding the interface selected are described in the following sections.

NOTE The signals relative to the selected interface are only available on the output connector if the jumper inside the scanner is correctly positioned. Refer to section 2.3.1 for further details.

Installation - 2.17

Page 33

LazerData® 16000 Scanner

Installation Manual

RS232 interface The main serial interface is used in this case for point-to-point connections; it handles communication with the Host computer and allows both transmission of code data and configuration of the scanner. The following pins of the 19-pin connector are used for RS232 interface connection: Pin Name Function T RXD Received data R TXD Transmitted data P RTS Request to send S CTS Clear to send N DGND Digital Ground The RTS and CTS signals control data transmission and synchronize the connected devices. If the RTS/CTS hardware protocol is enabled, the scanner activates the RTS output to indicate a message can be transmitted. The receiving unit must activate the CTS input to enable the transmission. RTS DGND

TXD

CTS

RXD

16000 SCANNER

USER INTERFACE

T

RXD

R

TXD

P

RTS

S

CTS

N

DGND

TXD RXD

DGND

Figure 2.17 - RS232 connections

2.18 - Installation

Page 34

LazerData® 16000 Scanner

Installation Manual

RS485-nonpolled interface The RS485-nonpolled interface is a full duplex interface. RS485-nonpolled interface is used for point-to-point connections over longer distances than those acceptable for RS232 communications or in electrically noisy environments. Pin V R P T S

Name GNDRS485 TX 485+ TX 485RX 485+ RX 485TX485+

Function RS485 Ground Reference RS485 output (+) RS485 output (-) RS485 input (+) RS485 input (-)

TX485-

GNDRS485

RX485-

RX485+

USER INTERFACE

16000 SCANNER R

TX485+

P

TX485-

T

RX485+

S

RX485-

V

GNDRS485

RX485

TX485

GND

Figure 2.18 - RS485-nonpolled interface connections

Installation - 2.19

Page 35

LazerData® 16000 Scanner

Installation Manual

RS485-polled interface The RS485-polled interface is a Half Duplex (3 wires + shield) interface. The polled configuration can be used for Multidrop connections with a Multiplexer, or it can be used for a master-slave layout (see section 2.9.2 and 2.9.3). Device connection to the Multidrop line can be controlled externally through the RS485CNTR line. For example, it may be necessary to disconnect a scanner from the line if the device is damaged or the line is overloaded. To do this, apply a voltage from 12 to 30 VDC to the RS485CNTR signal using SGND as a reference. Pin V P R U

Name GNDRS485 TX RX 485TX RX 485+ RS485CNTR

Function RS485 Ground Reference Negative transmit/receive Positive transmit/receive Multidrop device disconnect

TXRX485-

RS485CNTR

TXRX485+

GNDRS485

USER INTERFACE

16000 SCANNER Vext 12 to 30 Vdc

B

VS

V GNDRS485

1

R

TXRX485+

7

P

TXRX485-

6

U

RS485CNTR

A

SGND

RS485GND RXTX+ RXTX-

GND

Figure 2.19 - RS485-polled interface connections

2.20 - Installation

Page 36

LazerData® 16000 Scanner

Installation Manual

The figure below shows a multidrop configuration with LazerData 16000 Scanners connected to a Multiplexer. max. 2 m.

120 Ohm

6.6 ft. 16000 SCANNER #x (up to 31)

R P V

16000 SCANNER #1

R P V

16000 SCANNER

R

#0

P V max. 1200 m. 1,312 yds.

TX485+ TX485GNDRS485

+RTX485 -RTX485

MULTIPLEXER RS485REF

120 Ohm

Figure 2.20 - LazerData 16000 Scanner multidrop connection to a multiplexer

20-mA C.L. interface The LazerData 16000 Scanner has two current generators (one for transmission and one for reception), allowing for both active and passive type connections. The following pins of the 19-pin output connector are used for the connections: Pin U V N R P T S

Name DRVIN DRVOUT C.L. GND CLOUT+ CLOUTCLIN+ CLIN-

Function input current generator output current generator generator reference Current Loop output (+) Current Loop output (-) Current Loop input (+) Current Loop input (-) Installation - 2.21