For the PSC 16000

Page 19

LazerData® 16000 Scanner

16000 SCANNER CONNECTOR MODEL

16000 SCANNER JUNCTION BOX MODEL

Figure 2.2 - Opening the LazerData 16000 Scanner

2.4 - Installation

Installation Manual

Page 20

LazerData® 16000 Scanner

Installation Manual

!

2.3.1

Main interface selection

The main serial interface of the LazerData 16000 Scanner offers the following communication types: • EIA RS232 • EIA RS485-nonpolled • EIA RS485-polled • 20-mA current loop The RS232 interface is factory set. To select the interface type: 1. Remove the connector or cable panel as described in section 2.3. 2. Position the jumper onto the correct connector as indicated in Figure 2.3 according to your model. 16000 SCANNER

CONNECTOR PANEL

16000 SCANNER

20 mA CL

RS232

RS485-polled

RS485-nonpolled

20 mA CL

RS232

RS485-polled

RS485-nonpolled

JBOX CABLE PANEL

Figure 2.3 - LazerData 16000 Scanner main interface selection

Installation - 2.5

Page 21

LazerData® 16000 Scanner

2.3.2

!

Installation Manual

Multidrop Address selection

When using the RS485-polled interface, the Multidrop address must be selected. Proceed as follows: 1. Open the panel as described in section 2.3. 2. Position the switches as desired, referring to Figure 2.4. 16000 SCANNER

12345

16000 SCANNER

ON

54321

DIP SWITCH

ON

DIP SWITCH

CONNECTOR PANEL

JBOX CABLE PANEL

Figure 2.4 - Multidrop address selection

The following table shows the Multidrop address settings where: 1 = ON

5

4

Position 3 2

1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0

1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0

1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0

2.6 - Installation

1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0

0 = OFF

Address 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

5

4

Position 3 2

1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0

1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0

1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0

1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0

Address 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Page 22

LazerData® 16000 Scanner

Installation Manual

!

2.3.3

Input selection

Two presence sensor inputs are provided (PS1 and PS2). They can be selected as both positive inputs (PNP) or as both negative inputs (NPN). Refer to the following figure: 16000 SCANNER

NPN

PNP

CONNECTOR PANEL

16000 SCANNER NPN PNP

JBOX CABLE PANEL

Figure 2.5 - Input selection for LazerData 16000 Scanner

Installation - 2.7

Page 23

LazerData® 16000 Scanner

2.4

Installation Manual

MECHANICAL INSTALLATION

The LazerData 16000 Scanner can be installed to operate in any position. There are 16 screw holes (M5 X 8) on the sides of the scanner for mounting. The diagrams below give all the information required for installation; refer to section 2.7 for correct positioning of the scanner with respect to the code passage zone.

mm inches

Figure 2.6 - Overall scanner dimensions - connector model

2.8 - Installation

Page 24

Installation Manual

LazerData® 16000 Scanner mm inches compression connectors PG7 N°6 Figure 2.7 - Overall scanner dimensions - junction box model.

Installation - 2.9

Page 25

LazerData® 16000 Scanner

2.5

Installation Manual

JUNCTION BOX (JBOX) INSTALLATION

The JBOX provides a passive connection between your scanner and the outside world in a fast, practical way. It represents an alternative to other standard connectors. Figure 2.8 shows the basic layout of a scanner using the junction box. Scanner cable

Junction Box

16000 SCANNER System cables

Figure 2.8 - Scanner using JBOX

For JBOX connections, the scanner has a cable that terminates in a 24-pin connector that plugs into the junction box. The system cables pass through six compression connectors on the side of the JBOX. The individual wires of the cables connect to spring-clamp terminal blocks inside the JBOX, which provide access to all scanner signals. Refer to Figure 2.7 for the JBOX overall dimensions.

2.5.1 Mounting JBOX JBOX is designed to be mounted to a panel of metal, plastic or other appropriate material using the mounting screws provided in the package. To do this: 1) Open the junction box by unscrewing the four cover screws. You can use the JBOX as a template. Mark the panel through the screw holes in the JBOX, set the JBOX aside, and drill two small pilot holes in the panel. 2) Align the junction box with the pilot holes, insert the two self-threading screws with their washers, and screw them into the panel until the JBOX is tight against the panel (see Figure 2.9).

Figure 2.9 - Mounting JBOX

2.10 - Installation

Page 26

LazerData® 16000 Scanner

Installation Manual

2.5.2 Wiring the JBOX To wire the JBOX for your electrical connections: 1) Open the junction box by unscrewing the four cover screws. 2) Pass all system cables through the compression connectors in the junction box housing. 3) To connect the power and input/output signals: • Prepare the individual wires of the system cables by stripping the insulation back approximately 11 mm (~ 0.4 inch). • Using a device such as a screwdriver, push down on the orange lever directly above the clamp (see Figure 2.10). • Insert the wire into the clamp and release the lever. The wire will now be held in the spring clamp.

Figure 2.10 - System cable connections to the junction box

Use solid or stranded wire that meets the following specifications: Positions 1-4: Positions 5-39:

24 - 16 AWG 26 - 20 AWG

0.2 – 1.5 mm2 0.14 – 0.5 mm2

The junction box pinouts are indicated in the following table:

Installation - 2.11

Page 27

LazerData® 16000 Scanner

Installation Manual

18

J1

39

1

5

17

Figure 2.11 - JBOX connector and pinout

Pin

JBOX Pinout for LazerData 16000 Scanner Name Pin Name

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20

VS SGND VS SGND CHASSIS VS VS ENC+ ENCSGND SGND VS VS PS1+/PS2+/SGND SGND NOREAD+ NOREADRIGHT+

21 22 23 *24 *25 *26 27 28 29 30 31 32 33 34 35 36 37 38 39

RIGHTI.U. I.U. TXD/TX485+/CLOUT+ RTS/TX485-/CLOUTGNDRS485/DRVOUT RS485CNTR/DRVIN SGND TXD/TX485+/CLOUT+ RTS/TX485-/CLOUTGNDRS485/DRVOUT RXD/RX485+/CLIN+ CTS/RX485-/CLINSGND TXA AUX485+ SGND RXA AUX485-

* The signals on pins 24, 25, and 26 are repeated on pins 29, 30, and 31 to facilitate network connections (that is, multiplexer using the RS485-polled interface). In this way the network bus can enter and exit the junction box from different spring clamps but be physically connected together.

4) After wiring the junction box and while the scanner is unplugged from power, place the scanner cable so that the rubber seal fits into the cutout in the housing of the junction box. Plug the 24-pin connector into connector J1 on the PCB inside the junction box as shown in Figure 2.12.

2.12 - Installation