Page 10

The laser diode used in this device is classified as a Class 3B laser product according to IEC 825-1 regulations and as a Class IIIb laser product according to CDRH regulations. Because it is not possible to apply a classification label on the laser diode used in this device, the following label (Fig. D) is reproduced here:

LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT MAXIMUM OUTPUT RADIATION EMITTED WAVE LENGTH TO IEC 825-1 (1993)

10 mW 650~680 nm

Figure D. Laser diode class label

Any changes made to the laser diode’s optic elements, in particular, can cause the diode’s radiation level to increase to its maximum level (10 mW at 650~680 nm).

ix

Page 11

x

Page 12

Installation Manual

1.

GENERAL FEATURES

1.1

INTRODUCTION

LazerData® 16000 Scanner

The LazerData 16000 Series Bar Code Scanner is a bar code reader complete with decoder. This scanner is designed to provide an inexpensive solution in omnidirectional reading applications by combining the following advanced technologies with PSC’s solid experience in the material-handling sector.

ACR™ Technology Advanced Code Reconstruction Technology (ACR™) allows the reading of lowaspect-ratio labels placed anywhere on a parcel and also enhances the readability of poorly printed or damaged codes.

CD SQUARE™ Technology CD SQUARE™ Technology provides useful information on label position and object shape elaborated during the bar code reading phase. This innovative technology identifies the location area of the code and measures the code distance from the scanner.

PACKTRACK™ System The PackTrack™ System is a patented parcel-tracking system that improves the reading features in omnidirectional stations. In particular, the PackTrack™ System manages six-sided reading systems when it is impossible to detect the real position of the code on the parcel, thus overcoming the need for external accessories essential in traditional tracking systems.

Flexibility The high-frequency laser diode modulation system guarantees complete immunity to ambient light and allows installation of the LazerData 16000 Scanner in any working area. General Features - 1.1

Page 13

LazerData® 16000 Scanner

Installation Manual

The 16000 Scanner is provided with an Adjustable Focus System that enables users to freely select the most suitable reading field for their application. Focus length can be very easily adjusted by choosing among six different positions of the optical system. The LazerData 16000 Scanner is easily configurable by means of the user-friendly Windows-based LDHOST configuration program provided on a diskette. It is also possible to configure the scanner either through the built-in keypad or by sending ESC sequences from a Host computer.

1.2

DESCRIPTION

The main features of the LazerData 16000 Scanner are: • scanning speed of 800 scans/s for standard models; higher speeds available on request

• two serial communication interfaces

• readability of all popular codes

• supply voltage range from 10 to 30 VDC

• electrical connection via connectors or junction box

• test mode, to verify the reading features and exact positioning of the scanner without the need for external tools

• programmable in five different operating modes, to suit the most varied bar code reading system requirements

• light source, solid-state laser diode; the wavelength of the emitted light is 650~680 nm. For laser safety precautions refer to the “Safety Precautions” section at the beginning of this manual.

• low power consumption.

•

IP65 protection class of the enclosure, the reader is suitable for industrial environments where protection against harsh external conditions is required.

1.2 - General Features

Page 14

LazerData® 16000 Scanner

Installation Manual

1.2.1

Indicators

The LazerData 16000 Scanner has three LEDs and an LCD display on the front panel, one LED on the side panel, and an internal beeper. The indicators have the following functions: EXT TRIG yellow – indicates the external presence sensor is active (Figure A, 9 ).

GOOD READ red

TX DATA green – indicates the main serial interface is operating correctly during data transmission (Figure A, 7 )

– indicates a probable code is present in the reading zone (Figure A, 8 ).

LASER ACTIVE green – indicates the laser beam for bar code reading is active (Figure A, 2 ) LCD

1.3

The LCD displays messages to indicate the LazerData 16000 Scanner configuration and the code read after decoding. It is a 2- by 16-character display (Figure A, 6 )

AVAILABLE MODELS

The 16000 Scanner is available in two models with different connection systems: LD160101: connector model LD160102: junction box model

1.4

ACCESSORIES

The following LazerData 16000 Scanner accessories are available on request: • LD16-90DEG: 90° deflection mirror • LD16-MOUNT: mounting bracket

General Features - 1.3

Page 15

LazerData® 16000 Scanner

1.5

Installation Manual

APPLICATIONS

The LazerData 16000 Bar Code Scanner was specifically designed for industrial applications and for all applications that require high reading performance, such as: • • • • code reconstruction reading of codes with a wide depth of field reading of high resolution codes positioned at long distances from the reader code reading on fast moving objects

The LazerData 16000 Scanner is designed for both single- and multi-reader layouts. For typical layouts, see section 2.9.

1.4 - General Features

Page 16

LazerData® 16000 Scanner

Installation Manual

2.

INSTALLATION

2.1

LIST OF PARTS

When you open your LazerData 16000 Scanner package, ensure all the following parts (see Figure 2.1) are supplied and intact: 1) LazerData 16000 Series Scanner 2) This installation manual + bar code test chart 3) LazerData 16000 Scanner configuration program disk 4) Mounting screws Junction Box model 8) JBOX

Connector model 5) 3-pin female connector (power supply) 6) 6-pin male connector (inputs) 7) 19-pin male connector (outputs) 2 3 5

6

7

4

8 1

Figure 2.1 - Scanner package contents

Installation - 2.1

Page 17

LazerData® 16000 Scanner

2.2

Installation Manual

GUIDE TO INSTALLATION

Use the following checklist to ensure a complete installation of your LazerData 16000 Scanner. 1. Read all information in the section “Safety Precautions” at the beginning of this manual. 2. Correctly position and mount the scanner for bar code reading according to the information in sections 2.3, 2.4, 2.7, 2.8, and 3.3. 3. Provide correct system cabling according to the signals necessary (see the applicable subsections under sections 2.5 or 2.6). 4. Configure the software parameters from a host computer using the LDHOST interface utility program provided on diskette, or using the keyboard mode through the keypad and the display, or using the Host Mode programming procedure by ESC sequences via the serial interface. For more details about these configuration methods, refer to the section “LazerData 16000 Scanner Configuration” in the Help Online of the LDHOST utility program. NOTE Fine tuning of the scanner position for bar code reading can be accomplished using the Test Mode as described in LDHOST.

The installation is now complete.

2.2 - Installation

Page 18

LazerData® 16000 Scanner

Installation Manual

!

2.3

OPENING THE SCANNER

Before installing the LazerData 16000® Scanner, it may be necessary to open the scanner to perform the following operations: • select the main serial interface type (see section 2.3.1) • set the multidrop address (see section 2.3.2) • select the input type (see section 2.3.3)

WARNING Disconnect the power supply cable, before you unscrew the connector or cable panel of the LazerData 16000 Scanner, to prevent shock.

Refer to the following instructions and Figure 2.2 when opening the reader: 1. The part of the device to be opened is the connector or cable panel on the side of the scanner. 2. Unscrew the four screws to open the scanner. 3. Carefully remove the panel as shown in Figure 2.2. Pay attention not to stretch the flat ribbon cables between the panel and the scanner.

Installation - 2.3