Page 10

scanner is out of signal range and data will transmit to server when the scanner is back to the service range. The Xi3000-BT can work offline and store the reading data into the internal Flash memory for later upload to the host. The stored data can be up to 128Kbytes. 4.4.1 Transmit Buffer Setting Please enable the transmit buffer by scanning transmit buffer setting ENABLE label. Disable the manual memory function by scanning the DISABLE transmit buffer setting. 4.4.2 Memory Mode Please enable the manual memory function by scanning the memory mode ENABLE label. Disable the manual memory function by scanning the DISABLE memory mode label. 4.4.3 Clear Data The CLEAR label will enable the user to CLEAR or ERASE the data in the scanner’s memory. The user must also scan the CONFIRM label immediately after the CLEAR label. 4.4.4 Send Data This enables the user to transmit the data in the scanner’s memory to the host. The interface selected by the user will be used for the transmission. During the transmission the red LED of Xi3000-BT will be flashing. 4.4.5 Memory Data Delay This will enable the user to set a delay between each data records in memory at time of transmission.

5. Bluetooth Serial Port The Xi3000-BT can be configured to the standard Bluetooth Serial Port as the data output interface. This will make the Xi3000-BT send the scanned barcode data to Bluetooth enabled computer or PDA directly without the Xi3000-BTSTAND (however, a charging dock is still needed for charging the Xi3000-BT battery). This section illustrates a step-by-step installation and configuration procedures of the Xi3000-BT for Bluetooth Serial Port. Bluetooth transceivers/dongles always come with their own driver or Windows XP with service pack2 provides the buildin Bluetooth driver. There are several Bluetooth device drivers for Windows and WinCE/Pocket PC from different companies. Here we use Window XP with service pack2 build-in Bluetooth driver and BELKIN driver as examples. For detail installation procedures, please refer to the user’s manual of the Bluetooth transceiver in use.

5.1 Configuring Xi3000-BT Before starting the configuration, the scanner must be powered up. If you have not done so, please follow the procedures described in section 2.2 “Power Up the Xi3000-BT” to power up the scanner. First step of the configuration is always to put the scanner in configuration mode by scanning the “Enter Setup” barcode. After all the desired configurations are done, the “Update” barcode must be scanned to save the new settings and put the scanner back to normal operation mode. 5.1.1 Activate Bluetooth Serial Port Interface Scan the “Activate Bluetooth Serial Port” barcode will change the interface type to Bluetooth Serial Port. 5.1.2 Authentication & PIN Code The Xi3000-BT can do connection authentication if communication security is desired. Once this setting is enabled, a user configurable PIN code is verified during connection establishment. The scanner will refuse connection if the PIN code is incorrect. User can specify up to six characters of PIN code. 5.1.3 Device Name Broadcasting The scanner can be configured to hide itself by NOT broadcasting itself on the air. This can avoid unwanted computer/PDA from connecting to the scanner. But for

13

14

Page 11

the initial (first time) connection setup, this setting must be enabled. User can disable this setting for security reasons after initial connection setup is completed.

3.

Check My device is set up and ready to be found and click Next button.

5.1.4 Update Settings After all the desired settings are completed, the “Update” barcode must be scanned to make the new settings effective. The scanner will re-start itself after “Update” barcode is scanned. 5.1.5 Timeout The scanner will stay active only for one minute waiting for connection. If there is no connection request during that period, the scanner will go to power down mode to conserve power with three serial descending tones as indication. User can make the scanner go back to active mode by pulling the trigger. And again, the scanner will stay active for another one minute waiting for connection before it goes to power down mode again. Once there is a successful connection, the scanner will stay active until the connection is closed (when the host application closes the COM port). After the connection is closed, the scanner will again wait for new connection request for one minute before it goes to power down mode.

4. Select Xi3000-BT scanner and click Next button for next step.

5.2 Configuring Bluetooth Device Driver Please follow the procedures below to configure the Bluetooth driver on the host system. Please note that, when searching nearby Bluetooth devices on Host computers, the Xi3000-BT will come out with the serial number as their device name. Please check the serial number label on the scanner when making connections. 6. Enter the PIN code and click Next button for next step. The authentication PIN code is always asked from the Window XP built-in driver, so the user has to set Xi3000-BT scanner with Authentication and PIN code. In this case, 1 is the passkey.

5.2.1 Windows XP with Service Pack2 1.

Insert the Bluetooth dongle into PC host.

2.

Double click the Bluetooth icon on the lower right of the taskbar.

15

16

Page 12

7. The serial ports are assigned to the device, outgoing COM 10 and Incoming COM 11. Click the Finish button to complete the configuration.

3. Select Client Applications tab and select Bluetooth Serial Port from the list then click Property button.

4. Check Secure Connection if you enable the Authentication and have configured a PIN Code on 1x66. Otherwise uncheck Secure Connection. Click Apply and OK button.

5.2.2 Belkin Bluetooth Driver 1. Click Go to My Computer.

2. Double click the My Bluetooth Places at left Folders window. Right click My Device and select Property.

17

18

Page 13

7. Double click on the service, COM1, which is the Bluetooth Serial Port service. This will enable the connecting process. If Authentication (Secure Connection) is enabled, another window might pop up and asking for PIN code.

5. Wake up Xi3000-BT by pulling the trigger (just in case it falls asleep). Double click Find Bluetooth Devices. 8.

Click OK button. After successful connection, the Bluetooth Device Driver will report the COM port number, which is mapped for this connection. In this case, it is COM3. You can also hear three serial ascending tones from the scanner indicating successful connection. After this initial connection, whenever an application program opens COM3, the Bluetooth driver will automatically try to connect this particular scanner.

6.

Double click Xi3000-BT scanner.

19

20

Page 14

9. Right click the COM1 and select Disconnect to close the connection. There will be three serial descending tones from the scanner to indicate this condition. After the connection is closed, the Xi3000-BT scanner and the Bluetooth driver are properly configured and are ready to go. User can now run their application or “Hyper Terminal” for testing, and make the best use of this scanner.

6. Bluetooth HID The Xi3000-BT scanner can be configured to the standard Bluetooth HID as data output interface. This will make the Xi3000-BT scanner sends the scanned barcode data to Bluetooth enabled computer or PDA directly without the Xi3000BTSTAND (however, a charging dock is still needed for charging the Xi3000-BT battery). This section illustrates a step-by-step installation and configuration procedures of the Xi3000-BT for Bluetooth HID. Bluetooth transceivers/dongles always come with their own driver or Windows XP with service pack2 provides the build-in Bluetooth driver. There are several Bluetooth device drivers for Windows and WinCE/Pocket PC from different companies. Here we use Window XP with service pack2 build-in Bluetooth driver and WIDCOMM driver as examples. For detail installation procedures, please refer to the user’s manual of the Bluetooth transceiver in use. NOTE: Bluetooth HID doesn’t support the following functions on PDA:

„ „ „

Capital Lock Setting: Auto Detection Digit Transmission: Numeric Key Alt Composing

6.1 Configuring Xi3000-BT Before starting the configuration, the scanner must be powered up. If you have not done so, please follow the procedures described in section 2.2 “Power Up the Xi3000-BT” to power up the scanner. First step of the configuration is always to put the scanner in configuration mode by scanning the “Enter Setup” barcode. After all the desired configurations are done, the “Update” barcode must be scanned to save the new settings and put the scanner back to normal operation mode. 6.1.1 Activate Bluetooth HID Interface The HID keyboard interface is enabled by configuring/selecting the HID keyboard type. The supported HID keyboard types are listed below: US, French German, Italian, Swedish, Norwegian, UK, Belgium, Spanish, and Portuguese KBD.

21

22

Page 15

6.1.2 Reset Connection

The digit layout style can be changed by the following configuration settings. There are three options: Default, Lower Row, and Upper Row. The scanner will make necessary adjustment when sending digits according to the setting value of this parameter. This setting is used with the above setting (Keyboard Style – Alphabets) and perhaps Character Substitution setting, when support to languages not available on the scanner is needed.

Scan the “Reset Connection” when switch connection from one PC to another PC. The scanner will re-start itself after this barcode is read. 6.1.3 Authentication & PIN Code The Xi3000-BT scanner can do connection authentication if communication security is desired. Once this setting is enabled, a user configurable PIN code is verified during connection establishment. The scanner will refuse connection if the PIN code is incorrect. User can specify up to six characters of PIN code.

! 1

@ 2

# 3

$ 4

Digits on Lower Row

6.1.4 Device Name Broadcasting The scanner can be configured to hide itself by NOT broadcasting itself on the air. This can avoid unwanted computer/PDA from connecting to the scanner. But for the initial (first time) connection setup, this setting must be enabled. User can disable this setting for security reasons after initial connection setup is completed.

1 !

2 @

3 #

4 $

Digits on Upper Row 6.1.5 Update Settings After all the desired settings are completed, the “Update” barcode must be scanned to make the new settings effective. The scanner will re-start itself after “Update” barcode is scanned.

6.2 HID Keyboard Interface

6.2.4 Capital Lock Status In order to send alphabets with correct case, the scanner needs to know the capital lock status of the keyboard. Incorrect settings may result in reversed case of alphabets being transmitted. There are 3 options to this parameter: On, Off, or Auto Detection. If this parameter is set to Auto Detection, the scanner will automatically detect the capital lock status of the keyboard before it transmits data.

6.2.1 Keyboard Type The HID keyboard interface is enabled by configuring/selecting keyboard type. The supported keyboard types are listed below.

6.2.5 Alphabets Transmission User can choose how alphabets are sent by this parameter configuration. The alphabets can be sent according to their case (the Case Sensitive option), or the case is ignored (the Ignore Case option) when transmitting.

• PCAT - US, French German, Italian, Swedish, Norwegian, UK, Belgium, Spanish, and Portuguese KBD 6.2.2 Keyboard Style - Alphabets Keyboard layout style can be selected. There are three options to this setting: default layout (US or English style), AZERTY layout, and QWERTZ layout. This setting only works when the keyboard type selected is for US keyboard. The scanner will make necessary adjustment when sending the ‘A’, ‘Q’, ‘W’, ‘Z’, ‘Y’, and ‘M’ character according to this setting.

6.2.6 Digits Transmission User can choose how the scanner transmits digits by configuring this parameter. The scanner can transmit digits by using the alphanumeric key or by using the numeric keypad. The Num Lock status of the keyboard should be ON if numeric keypad option is selected. Numeric Key Pad

Deleted:

6.2.3 Keyboard Style – Digits There are two digit layout styles as shown on the following figures. One has digit on top (upper row) of a key and another has digits on bottom (lower row) of a key.

23

24

Alpha Numeric Key

Page 16

6.3 Configuring Bluetooth Device Driver Please follow the procedures below to configure the Bluetooth driver on the host system. Please note that, when searching nearby Bluetooth devices on Host computers, the Xi3000-BT scanner will come out with the serial number as their device name. Please check the serial number label on the scanner when making connections.

5.

Select the Xi3000-BT scanner and click Next button.

6.

Select Let me choose my own passkey and input the passkey in the text field and click Next button.

7.

When the connection is ready, a message will be displayed : Found New Hardware Bluetooth HID Device. Please click Finish button to complete the connection.

6.3.1 Windows XP with Service Pack2 1. Insert the Bluetooth dongle into PC host. 2.

Double click the Bluetooth icon

3.

Click Add button.

4.

on the lower right of the taskbar.

Check My device is set up and ready to be found and click Next button.

25

26

Page 17

3.

Right click the Xi3000-BT scanner and select Pair Device.

4.

Input PIN code and click OK button.

5.

Right click Xi3000-BT scanner and select Discover Available Services.

8. The scanner is ready to use. Please click OK button.

6.3.2 Widcomm Bluetooth Driver icon at PC.

1.

Click

2.

Click Find Bluetooth Devices icon at My Bluetooth Places.

27

28

Page 18

6.

7. Symbology Parameters

Click PC Remote Commander icon.

This section describes user configurable parameters that are pertaining to barcode symbologies.

7.1 Code39 • Standard / Full ASCII Code 39: User can choose to read either Standard Code 39 or Full ASCII Code 39 by configuring this parameter. 7.

• Start/Stop Transmission: This parameter specifies whether the start/stop characters of Code 39 are included in the data being transmitted.

Click Yes Button.

• Checksum Verification: This parameter specifies whether the scanner will perform checksum verification when decoding barcodes. If the checksum is incorrect, the barcode will not be read.

No

• Checksum Transmission: This parameter specifies whether the checksum characters are included in the data being transmitted.

8.

7.2 Italy / French Pharmacode

When the green arrow icon is displayed, the connection is ready.

For Italy /French Pharmacode, there is always a checksum character included in the barcode. So the checksum verification is always performed when decoding these symbologies. User though can choose whether the checksum character is to be transmitted or not. The start / stop transmission of this code shares the same setting of Code 39. • Checksum Transmission: This parameter specifies whether the checksum character is included in the data being transmitted.

7.3 Industrial / Interleave / Matrix 25 • Start / Stop Selection: This parameter provides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 25 barcode but with Interleave 25 start / stop. In order to read this barcode, the start / stop selection parameter of Industrial 25 should set to ‘Interleave 25. • Checksum Verification: This parameter specifies whether the scanner will perform checksum verification when decoding barcodes. If the checksum is incorrect, the barcode will not be read.

29