Page 1

Xi3000 Bluetooth Scanner

WARNING This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correcting the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. If applicable, as below FCC Caution: To assure continued compliance, (example – use only shielded interface cables when connecting to computer or peripheral devices). Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

User’s Manual

FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Page 2

4.4.1 4.4.2 4.4.3 4.4.4 4.4.5

Table of Contents 1.

INTRODUCTION...........................................................................................1

2.

Xi3000-BTSTAND INSTALLATION...........................................................2

5.

GENERAL FEATURES ................................................................................6 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9

4.

6.

BLUETOOTH HID ...................................................................................... 22 6.1 CONFIGURING Xi3000 ............................................................................. 22 6.1.1 Activate Bluetooth HID Interface ................................................... 22 6.1.2 Reset Connection ............................................................................ 23 6.1.3 Authentication & PIN Code ............................................................ 23 6.1.4 Device Name Broadcasting ............................................................ 23 6.1.5 Update Settings ............................................................................... 23 6.2 HID KEYBOARD INTERFACE.................................................................... 23 6.2.1 Keyboard Type................................................................................ 23 6.2.2 Keyboard Style - Alphabets............................................................. 23 6.2.3 Keyboard Style – Digits .................................................................. 23 6.2.4 Capital Lock Status......................................................................... 24 6.2.5 Alphabets Transmission.................................................................. 24 6.2.6 Digits Transmission ........................................................................ 24 6.3 CONFIGURING BLUETOOTH DEVICE DRIVER ........................................... 25 6.3.1 Windows XP with Service Pack2 .................................................... 25 6.3.2 Widcomm Bluetooth Driver ............................................................ 27

BUZZER......................................................................................................6 INDICATOR .................................................................................................6 SCAN MODES .............................................................................................6 AUTO-SENSE..............................................................................................7 RE-READ DELAY ........................................................................................8 SCANNER TIME-OUT DURATION ................................................................8 READING REDUNDANCY ............................................................................8 SUPPORTED SYMBOLOGIES ........................................................................8 NEGATIVE BARCODES................................................................................9

OUTPUT INTERFACE (Xi3000-BTSTAND)............................................10 4.1 KEYBOARD WEDGE INTERFACE ...............................................................10 4.1.1 Keyboard Type ................................................................................10 4.1.2 Keyboard Style - Alphabets.............................................................10 4.1.3 Keyboard Style – Digits ..................................................................10 4.1.4 Capital Lock Status .........................................................................11 4.1.5 Alphabets Transmission ..................................................................11 4.1.6 Digits Transmission ........................................................................11 4.1.7 Inter-Character Delay.....................................................................11 4.2 RS232 INTERFACE ...................................................................................12 4.2.1 Baud Rate / Parity / Data Bits.........................................................12 4.2.2 Flow Control ...................................................................................12 4.2.3 Inter-Character Delay.....................................................................12 4.3 USB INTERFACE ......................................................................................12 4.4 MEMORY PARAMETERS ...........................................................................12

BLUETOOTH SERIAL PORT................................................................... 14 5.1 CONFIGURING Xi3000-BT....................................................................... 14 5.1.1 Activate Bluetooth Serial Port Interface......................................... 14 5.1.2 Authentication & PIN Code ............................................................ 14 5.1.3 Device Name Broadcasting ............................................................ 14 5.1.4 Update Settings ............................................................................... 15 5.1.5 Timeout ........................................................................................... 15 5.2 CONFIGURING BLUETOOTH DEVICE DRIVER ........................................... 15 5.2.1 Windows XP with Service Pack2 .................................................... 15 5.2.2 Belkin Bluetooth Driver .................................................................. 17

2.1 POWER UP THE Xi3000-BTSTAND ..........................................................2 2.2 POWER UP THE Xi3000-BT .......................................................................3 2.3 SETUP RF CONNECTION .............................................................................3 2.4 CHARGING YOUR Xi3000-BT ....................................................................4 2.4.1 Scanner .............................................................................................4 2.4.2 Battery...............................................................................................4 2.4.3 DC Jack.............................................................................................5 2.5 INTERFACE SETTING ..................................................................................5 3.

Transmit Buffer Setting ................................................................... 13 Memory Mode................................................................................. 13 Clear Data ...................................................................................... 13 Send Data........................................................................................ 13 Memory Data Delay........................................................................ 13

7.

SYMBOLOGY PARAMETERS ................................................................. 30 7.1 7.2 7.3 7.4 7.5 7.6 7.7

CODE39 ................................................................................................... 30 ITALY / FRENCH PHARMACODE ............................................................... 30 INDUSTRIAL / INTERLEAVE / MATRIX 25.................................................. 30 CODABAR ................................................................................................ 31 UPCE ...................................................................................................... 31 EAN8 ...................................................................................................... 32 UPCA...................................................................................................... 32

Page 3

7.8 7.9 7.10 7.11 7.12 8.

EAN13 ....................................................................................................32 MSI .........................................................................................................32 PLESSEY...................................................................................................33 TELEPEN ..................................................................................................33 RSS .........................................................................................................33

DATA OUTPUT FORMAT.........................................................................35 8.1 8.2 8.3 8.4

9.

CHARACTER SUBSTITUTION .....................................................................35 PREFIX / POSTFIX CODE ...........................................................................35 CODE ID ..................................................................................................35 LENGTH CODE .........................................................................................36

DATA EDITING...........................................................................................37 9.1 9.2 9.3 9.4 9.5 9.6 9.7 9.8 9.9 9.10 9.11

10.

SELECT EDITING FORMAT ........................................................................37 RESTORE DEFAULT FORMAT....................................................................37 APPLICABLE CONDITIONS ........................................................................38 TOTAL NUMBER OF FIELDS ......................................................................38 DIVIDING DATA INTO FIELDS ...................................................................38 ADDITIONAL FIELDS ................................................................................39 FIELD TRANSMISSION SEQUENCE.............................................................39 END OF FORMAT PROGRAMMING .............................................................39 ACTIVATE DATA EDITING FORMATS........................................................39 EXCLUSIVE DATA EDITING ......................................................................40 PROGRAMMING EXAMPLES ......................................................................40 CONFIGURING YOUR Xi3000-BT.......................................................41

10.1 ENTER CONFIGURATION MODE................................................................41 10.2 DEFAULT .................................................................................................41 10.3 LIST SETTING ...........................................................................................41 10.4 SETTING PARAMETER VALUES.................................................................42 10.4.1 Numeric Parameters .......................................................................42 10.4.2 Character String Parameters..........................................................42 10.4.3 Key Type/Status Setting...................................................................43 10.5 EXIT CONFIGURATION MODE...................................................................44

Page 4

1. Introduction

2. Xi3000-BTSTAND Installation

The Xi3000-BT is POS-X’s Wireless scanner utilizing Bluetooth Technology. The scanner has a range of over 50 meters and a battery life is over 50 hours or 35,000 scans for the Xi3000-BT. The Xi3000-BT scanner uses CCD linear imager. This manual contains the information for operating and configuring the Xi3000-BT Wireless Barcode Scanner and is divided into two portions. The first portion describes the installation, operation and programmable features of the scanner. The second portion contains the setup barcodes used to configure the scanner. The Xi3000-BT is one of the most versatile and flexible wireless barcode scanners available today. The Xi3000-BT contains all the features and functions required for up to date barcode reading. Owing to the compact design and extremely low power consumption, this scanner provides for easy installation and high product durability. The scanner will not only satisfy for the requirements needed today, but also can fulfill your long-term needs. The main functions and features are listed below. • Barcode Readability: Most popular barcode symbologies are supported including the newest RSS Code. • Negative barcodes supported. • Eight scan modes supported. • Programmable Beeping Tone • Dual Color Indicator • Interface Support (base unit): KB Wedge, RS232, and USB • Bluetooth Serial Port Profile Supported: The scanner can transmit scanned data to Bluetooth enabled computer/PDA via standard Bluetooth Serial Port communication. • Bluetooth HID Supported: The scanner can transmit scanned data to Bluetooth enabled computer/PDA via standard HID communication. • Programmable Code ID: Code ID can be individually configured for each symbology. • Programmable Length Code • Programmable Prefix Code • Programmable Postfix Code • Character Substitution • Data Editing: Data can be reorganized according to user programmable formats. Up to three data editing formats are supported. • Extremely Low Power Consumption

The Xi3000-BT kit contains: (1) - Xi3000-BT wireless barcode scanner (1) - Xi3000-BTSTAND base (1) - Rechargeable battery (1) - A Serial/Keyboard/USB Cable (depending on configuration ordered) (1) - A power supply for the base or the scanner. (1) - Diskette containing “Scan Manager” and this manual

Note: Please refer to chapter 5 Bluetooth Serial Port for Bluetooth Serial Port installation and configuration instructions. 2.1 Power Up the Xi3000-BTSTAND

Connect the interface cable into the 15-pin connector at the back of the base. The interface of the cable depends on what you ordered. There are three types of cables available: RS232, Keyboard or USB. Power off your PC or Laptop when connect the cable to PC or Laptop. Once your cable is connected to the base, plug the other end into the appropriate port on your PC. For example, if you have a serial cable then plug into the com port of your PC, if you have a Keyboard cable then plug into keyboard port of your PC and if you have a USB cable plug into the USB port on your PC. Connect the power supply provided to your AC outlet and plug the other end into the base then power on your PC. Now you are ready to configure your scanner and base.

1

2

Page 5

2.2 Power Up the Xi3000-BT

2.4 Charging your Xi3000-BT

When you receive your Xi3000-BT, the battery is separated from Xi3000-BT. Please insert the battery into the bottom of the scanner and lock the battery by pushing the clip to power on the scanner. The scanner will beep and the LED will be on when power on.

There are three methods to charge the battery. Placing the scanner on the base, inserting the battery in front of the base or inserting the power supply into the DC Jack at bottom of the scanner. 2.4.1 Scanner

Push up to lock the battery. Please ensure to remove the battery to power off the scanner if it will not be used for a prolonged period. The LED will be off and the power to the scanner will be disconnected.

2.3 Setup RF Connection

Place the scanner with a battery inserted on the base to charge your scanner. When charging, the scanner LED will flash RED. When the battery is fully charged, around 4 hours from completely empty battery, the LED stays on solid RED.

Upon powering up the scanner will try to establish an RF connection with its base. At this stage we need to “pair” the scanner and base.

2.4.2 Battery

Turn the base upside down and you will find 2 labels. The first label has the words “SET CONNECTION” and a barcode. The second label is the serial number. To link the scanner to the base, scan the “SET CONNECTION” barcode label, the scanner will beep once then scan the SERIAL number barcode. The scanner will beep twice, low then high beep. When it establishes RF connection with the base the scanner will then emit three short ascending beeps. Your “pairing” is established. Insert the battery in front of the base to charge your battery with the power adaptor connected. When charging, the base charging LED will be RED. When the battery is fully charged, around 4 hours from completely empty battery, the LED will be solid GREEN.

3

4

Page 6

3. General Features 2.4.3 DC Jack

3.1 Buzzer The buzzer of the scanner beeps differently to indicate various operating conditions. • Power On Beep: The scanner will issue a long beep to indicate a successful power on.

Insert the power supply to the DC Jack at bottom of the scanner. When charging, the scanner LED will flash RED. When the battery is fully charged, around 4 hours from completely empty battery, the LED stays on solid RED.

• Good Read Beep: The system provides four volume levels and four beeping tones (frequencies) that the user can select from to signify a good read. The available options are: Volume: Maximum/Loud/Medium/Minimum Frequency: 8 / 4 / 2 / 1 kHz

2.5 Interface Setting

• Error Beep: The scanner will issue a long beep with a low tone to indicate errors.

Once you have “paired” the scanner and base, you need to specify the interface type to your PC. The interface settings are stored in the base. So ensure that you have RF connection between your scanner and base prior to setting the interface type. For details on selecting interfaces please refer to the relevant section in this manual.

• Enter / Exit Configuration Beep: The scanner will issue 6 beeps upon entering / exiting the configuration mode. • Setup Beep: In configuration mode, the scanner will normally beep twice when a setup barcode is read. If the particular setup parameter needs more than one read, the scanner will only issue a short beep to indicate that there are more setup barcodes needed to complete the current parameter setting.

3.2 Indicator There is a dual color indicator on top of the scanner. Normally it is off, and will turn red when there is a good read. The indicator will be blue when the scanner is at configuration mode.

3.3 Scan Modes There are eight scan modes supported by the scanner. The user can choose the desired scan mode depending on the application requirements. But, if the scanner is a trigger-less scanner, only continuous mode or testing mode can be selected (other scan modes involve trigger switch interaction). The supported scan modes are described below. • Auto Off Mode: The scanner will start scanning once the switch is triggered. The scanning continues until either a barcode is read or a preset scanning period (Scanner Time-Out Duration) is expired.

5

6

Page 7

• Continuous Mode: The scanner is always scanning.

3.5 Re-read Delay

• Auto Power Off Mode: The scanner will start scanning once the switch is triggered. The scanning continues until a preset scanning period (Scanner Time-Out Duration) is expired. Unlike the Auto Off mode, the scanner will continue to scan and the scanning period is re-counted each time there is a successful read. • Alternate Mode: The scanner will start scanning once the switch is triggered. The scanner will continue scanning until the switch is triggered again. • Momentary Mode: The scanner will be scanning as long as the switch is depressed. • Repeat Mode: The scanner is always scanning just like Continuous Mode. But now the switch acts like a “re-transmit button”. If the switch is triggered within 1 second after a good read, the same data will be transmitted again without actually reading the barcode. This “re-transmit button” can be triggered as many times as user desired, as long as the time between each triggering does not exceed 1 second. This scan mode is most useful when the same barcode is to be read many times.

If the scanner mode is set to Continuous, Auto Power Off, Alternate, or Momentary mode, the scanner will prevent accidentally reading the same barcode twice by using a Re-read Delay (Blocking Time). The barcode must be taken away from the scanning line longer than the Re-read Delay to allow second reading of the same barcode. The user can set the Re-read Delay if necessary.

3.6 Scanner Time-out Duration This parameter is used to limit the maximum scanning period when the scan mode is either Auto Off Mode or Auto Power Off Mode. This time-out duration is specified in units of second. The default time-out duration is ten seconds.

3.7 Reading Redundancy

• Laser Mode: This scan mode is used on laser scanners. The scanner will scan once when the trigger is pressed. The scanning continues until a barcode is read, the trigger is released or a preset scanning period (Scanner Time-Out Duration) is expired.

This parameter is used to specify the levels of reading (decoding) security. If No Redundancy is selected, only one successful decoding can make the reading valid. If Three Times Redundancy is selected, it will take 3 successful decodes to make the reading valid. It is obvious that the more redundancy the user selects, the higher the reading security and thus the slower the reading speed. The user must compromise between decoding security and decoding speed if the security feature is needed.

• Test Mode: The scanner is always scanning. The scanner will decode repeatedly even with the same barcode.

3.8 Supported Symbologies

By default, the scan mode is Auto Off mode for scanners with trigger switch, and is Continuous mode for switch-less scanners.

3.4 Auto-Sense

Most of the popular barcode symbologies are supported. Each symbology can be individually enabled or disabled. The scanner will automatically discriminate and recognize all the symbologies that are enabled. The supported barcode symbologies are listed below. • Code 39 (Standard / Full ASCII) • Italy Pharmacode • French Pharmacode • Industrial 25 • Interleave 25 • Matrix 25 • Codabar (NW-7) • UPCA (with or without Add-on) • UPCE (with or without Add-on)

. It will enable the scanner to start scanning once a barcode is brought within Range of the scanner. This will activate the LEDs and the scanner will start decoding the barcode. The auto-sense mode works only under Auto Off mode or Laser mode only.

7

8

Page 8

• EAN8 (with or without Add-on) • EAN13 (with or without Add-on) • Code 93 • Code 128 • EAN 128 • MSI • Telepen • Plessey

4. Output Interface (Xi3000-BTSTAND) The Xi3000-BT is a multi-interface scanner. It can be used as a keyboard wedge scanner, an RS-232 scanner, or a USB scanner. The output interface can be programmed using the setup barcodes in this manual. Please ensure that you have an RF connection between the scanner and the base prior to selecting the interface type.

3.9 Negative Barcodes

4.1 Keyboard Wedge Interface 4.1.1 Keyboard Type The keyboard wedge interface is enabled by configuring/selecting keyboard type. The supported keyboard types are listed below.

The scanner can be configured to read negative barcodes. Normally, barcodes are printed with the color of the bars darker than that of the spaces. But for negative barcodes, they are printed in the opposite sense just like negative films. The spaces of the negative barcodes are printed with a color darker than that of the bars.

• PCAT - US, French German, Italian, Swedish, Norwegian, UK, Belgium, Spanish, and Portuguese KBD • PS2-30 • IBM 3477 TYPE (Japanese KBD) • IBM 34XX, 319X & Memorex Telex (122Keys) 4.1.2 Keyboard Style - Alphabets Keyboard layout style can be selected. There are three options to this setting: default layout (US or English style), AZERTY layout, and QWERTZ layout. This setting only works when the keyboard type selected is for US keyboard. The scanner will make necessary adjustment when sending the ‘A’, ‘Q’, ‘W’, ‘Z’, ‘Y’, and ‘M’ character according to this setting. 4.1.3 Keyboard Style – Digits There are two digit layout styles as shown on the following figures. One has digit on top (upper row) of a key and another has digits on bottom (lower row) of a key. The digit layout style can be changed by the following configuration settings. There are three options: Default, Lower Row, and Upper Row. The scanner will make necessary adjustment when sending digits according to the setting value of this parameter. This setting is used with the above setting (Keyboard Style – Alphabets) and perhaps Character Substitution setting, when support to languages not available on the scanner is needed. ! 1

@ 2

# 3

Digits on Lower Row

9

10

$ 4

Deleted:

Page 9

1 !

2 @

3 #

4.2 RS232 Interface

4 $

User can select the desired, flow control, baud rate, parity, and data bits to be used in this output interface.

Digits on Upper Row

4.1.4 Capital Lock Status In order to send alphabets with correct case, the scanner needs to know the capital lock status of the keyboard. Incorrect settings may result in reversed case of alphabets being transmitted. There are 3 options to this parameter: On, Off, or Auto Detection. If this parameter is set to Auto Detection, the scanner will automatically detect the capital lock status of the keyboard before it transmits data. 4.1.5 Alphabets Transmission User can choose how alphabets are sent by this parameter configuration. The alphabets can be sent according to their case (the Case Sensitive option), or the case is ignored (the Ignore Case option) when transmitting. 4.1.6 Digits Transmission User can choose how the scanner transmits digits by configuring this parameter. The scanner can transmit digits by using the alphanumeric key or by using the numeric keypad. The Num Lock status of the keyboard should be ON if numeric keypad option is selected. Numeric Key Pad

4.2.1 Baud Rate / Parity / Data Bits The supported baud rate, parity, and data bit are listed below. • Baud Rate: 115200 / 38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 600 • Parity: None / Even / Odd • Data bit: 8 / 7 4.2.2 Flow Control The user can further configure the flow (handshake) control method to be used. The available options are listed below. • No Flow Control • Scanner Ready: The scanner will activate the RTS signal after power on. After each good read the scanner waits for an active CTS signal. The data will not be sent until CTS signal becomes active. • Data Ready: The RTS signal will be activated after each good read. The scanner will then wait for the CTS signal becomes active. The data will not be sent until CTS signal becomes active. • Inverted Data Ready: It is like the Data Ready flow control, but the RTS signal level is inverted. 4.2.3 Inter-Character Delay An inter-character delay of 0 to 255 ms can be configured to match the computer response time. The delay time configured is inserted between transmitting every character. The longer the delay time configured, the slower the transmission speed will be. The inter-character delay is zero by default.

4.3 USB Interface

Alpha Numeric Key 4.1.7 Inter-Character Delay An inter-character delay of 0 to 255 ms can be configured to match the computer response time of the keyboard interface. The delay time configured is inserted between transmitting every character. The longer the delay time configured, the slower the transmission speed will be. The inter-character delay is zero by default.

A USB interface is also available. For installation instructions please refer to the separate diskette included with your scanner.

4.4 Memory Parameters The Xi3000-BT reserves 4 KB flash memory as transmit buffer when the scanner is out of service range. Data will be saved into the reserved buffer when the