The text of a manual · part 3 of 3
Xi3000 Bluetooth Scanner User's Manual, pages 19 to 25
Pages 19 to 25 of 25
The original document is the PDF (703 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the POS-X Xi3000-BT
Page 19
• Checksum Transmission: This parameter specifies whether the checksum character is included in the data being transmitted.
• System Number Transmission: If this parameter is enabled, the system number will be included in the data being transmitted.
• Code Length Qualification: Because of the weak structure of the 2 of 5 codes, a partial scan has a high probability of decoding as a valid but shorter 2 of 5 codes (known as short scan). To prevent this kind of undesired reading, the Code Length settings can help to insure that the correct code is read by qualifying the allowable code length. Code length parameters can be configured in two ways: Fixed Code Length or Max / Min code length. If the fixed code length is selected, up to 2 fixed lengths can be specified. And if max / min code length is selected, the max length and the min length must be specified, and the scanner will only accept those codes with lengths fall between max / min length specified.
• Checksum Transmission: If this parameter is enabled, the checksum character will be included in the data being transmitted.
7.6 EAN8 • Convert to EAN13: If this parameter is enabled, the EAN8 read will be expanded into EAN13, and the following processing will follow the parameters configured for EAN13. • Checksum Transmission: If this parameter is enabled, the checksum character will be included in the data being transmitted.
7.4 Codabar • Start/Stop Transmission: This parameter specifies whether the start/stop characters of Codabar are included in the data being transmitted. • Start / Stop Selection: Four different start / stop pairs can be selected as start / stop characters as listed below. abcd / abcd abcd / tn*e ABCD / ABCD ABCD / TN*E
7.7 UPCA • Convert to EAN13: If this parameter is enabled, the UPCA read will be expanded into EAN13, and the following processing will follow the parameters configured for EAN13. • System Number Transmission: If this parameter is enabled, the system number will be included in the data being transmitted. • Checksum Transmission: If this parameter is enabled, the checksum character will be included in the data being transmitted.
7.5 UPCE • System Number Selection: The UPCE comes with 2 formats: System Number 0 and System Number 1. These two differ in the method of encoding data. The system number 1 is the new UPCE extension to the ordinary UPCE (system number 0). Users have the choice of enabling two system numbers or just system number 0. Warning: Because of the way system number 1 is encoded, if both system numbers are enabled, user might suffer from short scanning UPCA or EAN13 into UPCE system number 1 barcodes. • Convert to UPCA: If this parameter is enabled, the UPCE read will be expanded into UPCA, and the following processing will follow the parameters configured for UPCA.
31
7.8 EAN13 • ISBN / ISSN Conversion: If these parameters are enabled, the scanner will convert the code read into ISBN or ISSN code if the formats are correct (EAN13 codes start with 978 or 979 for ISBN, and 977 for ISSN). • Checksum Transmission: If this parameter is enabled, the checksum character will be included in the data being transmitted.
7.9 MSI
32
Page 20
• Checksum Verification: Three kinds of checksum calculations can be implemented into MSI code: Single Modulo 10, Double Modulo 10, or Modulo 11 & 10 checksum. If the checksum character is incorrect, the barcode will not be read.
• Code ID Transmission: If this parameter is enabled, the Code ID selected by the preceding setting will be included in the data being transmitted.
• Checksum Transmission: User can control the checksum transmit ion format by configuring this parameter. 1) Transmitted 2) Last digit not transmitted 3) Last 2 digits not transmitted
• Checksum Transmission: If this parameter is enabled, the checksum character will be transmitted together with data.
• Application ID Transmission: If this parameter is enabled, the Application ID will be included in the data being transmitted.
• Code Length Qualification: Because of the weak structure of the MSI code, a partial scan has a high probability of decoding as a valid but shorter MSI codes (known as short scan). To prevent this kind of undesired readings, the Code Length settings can help to ensure that the correct code is read by qualifying the allowable code length. Code length limitations can be set in 2 ways: Fixed Code Length and Max/Min code length. If the fixed code length is selected, up to 2 fixed lengths can be specified. And if max / min code length is selected, the max length and the min length must be specified, and the scanner will only accept those codes with lengths fall between max/min length specified.
7.10 Plessey • Convert to UK Plessey: If this parameter is enabled, the scanner will change each occurrence of the character ‘A’ into character ‘X’ in the code. • Checksum Transmission: If this parameter is enabled, the checksum characters (two characters) will be transmitted together with data.
7.11 Telepen • Telepen Output: There are two flavors of encoding formats for Telepen. One is the original Telepen format and another is AIM Telepen format. User can choose the desired encoding format for Telepen readings.
7.12 RSS • Code ID Selection: User has choice of using RSS Code ID (‘]e0’) or EAN128 Code ID (‘]C1’).
33
34
Page 21
8. Data Output Format Data read by the scanner will be processed in the following sequence (RS-232, Keyboard Wedge and USB interfaces). 1) The character substitution is performed on the barcode data. 2) The Code ID and the Length Code are inserted at the beginning of the data as shown below. [Code ID] [Length Code] [Data] 3) The resulting data of step 1 will be processed by the editing formats. For details, please refer to the section “Data Editing”. 4) And finally the Prefix Code and the Postfix Code will be added before transmission. [Prefix Code] [Resulting Data of Step 3] [Postfix Code]
Code 39 Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 25 Codabar Code 93 Code 128 UPCE EAN8 EAN13 MSI Plessey UPCA Telepen
Set 1 Set 2 Set 3 Set 4 Set 5 A C Y M A A C Y M A A C Y M A C H H H S D I Z I S E G G G S F N X N F I L L L G H K K K C S E C E E P B B FF E M A A F E V V D P M W W E Q P J A A A E Z
8.1 Character Substitution
8.4 Length Code
There are three character substitution settings on the scanner. These settings are configured on a character base. That is, a specific character is to be substituted by another character. The character substitution is performed on every occurrence of the characters specified in these settings. Be aware, the substitution is performed only on the barcode itself (exclude Prefix Code, Postfix Code, Code ID, Length Code or any Additional Field) and is performed before editing mode processing. If only the character to be replaced is specified, every occurrence of that character in the barcode will be taken away.
Two digits Length Code representing the length of data (character count) can be inserted in front of data being transmitted. This Length Code parameter can be individually enabled or disabled for each barcode symbology.
8.2 Prefix / Postfix Code Up to four characters of prefix / postfix code can be configured for the scanner.
8.3 Code ID Up to two characters of Code ID can be configured for each symbology. To minimize the Code ID configuration efforts, the scanner provides five predefined Code ID Sets that user can select from. User can first select one of the Code ID Sets and then make desired modifications. The pre-defined Code ID Sets are shown below.
35
36
Page 22
9. Data Editing
9.3 Applicable Conditions
The Xi3000-BT scanner provides advanced data editing functions for data formatting. Data editing is performed according to user configured editing formats. Up to three editing formats can be configured. Data is divided into fields by user specified rules. These fields together with user configurable additional fields constitute the data actually sent to the host computer. The detailed descriptions and the configuration procedures of the editing format are described in this section.
Three applicable conditions can be configured to qualify whether the data read by the scanner can be processed by the particular editing format. Data editing will not be performed unless all three applicable conditions are met. The configurable applicable conditions are described below.
9.1 Select Editing Format To start configuring an editing format, the editing format to be configured must first be selected. Once it is selected, the parameters pertaining to editing format (applicable condition, total number of field, field dividing rules, additional fields, and field transmission sequence parameters) can be configured. After all the desired parameters are configured, the “End of Format Programming” label must be read to complete the configuration of that editing format. Note: Before completing the configuration of the editing format, if parameters other than those pertaining to editing format are read, the editing format under configuration will be aborted. User must restart the configuration again by selecting editing format to be configured.
• Code Type: This parameter specifies the code type of the data eligible for data editing. Multiple code types can be specified for this parameter. • Data Length: This parameter specifies the length (character count) of the data eligible for data editing. It is specified in the range format. The length of the data must fall between max and min length limits. If the max length and the min length configured is both zero, the scanner will not perform this length qualification. • Matching String and its Location: User can specify a particular character string (up to four characters) that must appear in the data that is eligible for data editing. User can also specify where (character position, starts from one) this string should appear in the data by configuring the matching string location. If the location specified is zero, the scanner only checks for the existence of the matching string in the data. To disable the matching string qualification, just leave the matching string empty.
9.4 Total Number of Fields
9.2 Restore Default Format After the editing format to be configured is selected, user can read the “Restore Default Format” label to put the editing format back to default setting. The default settings of the editing format are listed below. • Applicable Code Type: All • Applicable Length: Max length and min length are zero. • Matching string: Empty • Matching String Location: 0 • Total number of field: 1 • Field Setting: Not Configured • Additional Fields: Empty • Field Transmission Sequence: F1
Data can be divided into at most 6 fields. The total number of fields must be correctly specified. The fields are numbered from F1 to F6 accordingly, but only F1 to F5 can be configured. Please note that, the number of fields can be configured is always one less than the total number of fields specified. The extra data characters beyond the last field configured will be automatically assigned to the next field. That is, if three fields are configured for the editing format, the data characters after F3 will be assigned to F4 automatically.
9.5 Dividing Data into Fields Data eligible for editing format is divided into fields according to user specified rules. The rule for each field can be configured in two ways. • Field Terminating String: The field division can be specified by termination string of the field. The field terminating string configured can be up to two characters. The scanner will search for the occurrence of this particular string in the data for the field. The field terminating string is
37
38
Page 23
always included in the field. User though, has the option of discarding this terminating string. • Field Length: The field division can be simply specified by the field length. The scanner will assign the next specified number of characters into the field.
9.6 Additional Fields
9.10 Exclusive Data Editing If this parameter is enabled, all data read by the scanner must be processed by the editing format. If the data is not eligible for all enabled editing formats, the scanner will not accept the reading and the data will not be transmitted.
9.11 Programming Examples
User can create up to five additional fields for each editing format. Each additional field can have at most four characters. The additional fields are numbered AF1 to AF5 accordingly.
9.7 Field Transmission Sequence After the data fields and the additional fields are configured, user can now program the transmission sequence of these fields that comprise the final data. The “Start” label must be read before assigning the field transmission sequence. And then the desired field transmission sequence can be specified. The scanner will transmit the fields in the order (sequence) user programmed when sending data. The field transmission sequence can be assigned in any desired order and fields can also be assigned multiple times. The maximum number of fields can be assigned is twelve. After the sequence has been assigned, the “End” label must be read to complete the setting.
Example 1: Extracts data from the 10th character to the 19th character. Total Number of Fields: 3 Field 1: Divide field by field length, set field length to 9 Field 2: Divide field by field length, set field length to 10 Field Transmission Sequence: F2 Example 2: Extract the date code, item number, and quantity information from barcodes. Data is encoded in the barcode like this: From the first character to the 6th character is the date code. From the 7th character is the item number, its length is not fixed but is delimited by a ‘-’ character. After the ‘-’ character is the quantity information. Data should be transmitted like this: Item number goes first, then a TAB character, and then the date code, and then another TAB character and finally the quantity. Total Number of Fields: 3
9.8 End of Format Programming After all the desired parameters are configured, the “End of Format Programming” label must be read to conclude the programming of the editing format. This label is located at the bottom of every even page in the “Editing Format Parameters” section of the configuration manual.
Field 1: Divide fields by field length and set the field length to 6. Field 2: Divide fields by field terminating string. Set terminating string to ‘-’, and discard the terminating string. Additional Field 1: Set to one TAB character. Field Transmission Sequence: F2 AF1 F1 AF1 F3
9.9 Activate Data Editing Formats Before data can be processed by a particular editing format, that format must be enabled. The editing formats can be enabled or disabled individually.
39
40
Page 24
10. Configuring your Xi3000-BT
10.4 Setting Parameter Values
The configuration of Xi3000-BT Scanner is done by reading the setup labels contained in the Configuration Manual (the second part of this manual). This section describes the procedure of configuring the scanner. Some configuration examples are also given in this section for illustration.
For most of the parameters, only one read is required to set them to new values. The scanner will respond with two beeps when these parameters are configured. But for some special parameters, multiple reads are required to complete the setting. The scanner will respond with a short beep if the configuration of the parameter is still not complete. These parameters usually refer to a numeric value or a string of characters, such as keyboard type, inter-character delay, prefix / postfix code, etc..
10.1 Enter Configuration Mode To start the configuration, the “Enter Setup” label must be read. This will put the scanner in the configuration mode. The scanner will respond with 6 beeps and the indicator will turn blue after the label is read. This “Enter Setup” label is located at the bottom of almost every even page of the Configuration Manual.
For these kinds of parameters, the label of the parameter to be configured must be read first. Then the labels comprising the numeric value or character string are read. Finally, the “Validate” label must be read to complete the setting. The scanner will respond with two beeps when the “Validate” label is read. 10.4.1 Numeric Parameters The configuration procedures for numeric parameters are shown below.
10.2 Default All the parameters of the scanner will return to their default values by reading the “Default” label. The scanner will beep twice when the “Default” label is read.
Parameter Label
10.3 List Setting
Decimal Label
The current setting of all scanner parameters can be sent to the host computer for user inspection. The listing is separated into ten pages. User can select the page of interest by reading the “Page x” label Page 1: Interface, Buzzer, and Scanner Parameters Page 2: Prefix, Postfix, and Length Code Setting Page 3: Code ID Page 4: Readable Symbologies Page 5: Symbology Parameters (1/3) Page 6: Symbology Parameters (2/3) Page 7: Symbology Parameters (3/3) Page 8: Editing Format 1 Page 9: Editing Format 2 Page 10: Editing Format 3
"Validate" Label For example, to configure the Inter-Character Delay to be 15 ms, the “InterCharacter Delay” label is first read, and then the decimal digit labels “1” and “5”, and finally, the “Validate” label to complete the setting. 10.4.2 Character String Parameters Basically, each character of a string is programmed by two hexadecimal digits, which usually comprise a value that is the ASCII code equivalence of the character being programmed. Beside the two hexadecimal digits, there is an optional key type/status can also be specified for each character of the string parameters. This optional key type/status can only be specified for some particular parameters when keyboard interface is
41
42
Page 25
used. These parameters are: Prefix Code, Postfix Code, Code ID, and Additional Fields of Editing Formats.
• Add Control (L): The left Control key will be sent together with the character programmed.
The available key type/status settings can be selected will be described briefly. The configuration procedures for character string parameters are shown below.
• Add Alternate (L): The left Alternate key will be sent together with the character programmed. • Add Control (R): The right Control key will be sent together with the character programmed.
Parameter Label
• Add Alternate (R): The right Alternate key will be sent together with the character programmed. For example, to program the Prefix Code to be “Ctrl-Shift-B”, “C”, the programming sequence should be: 1) “Prefix Code” label 2) “Add Control (L)” label 3) “Add Shift” label 4) “4” of the hexadecimal digit 5) “2” of the hexadecimal digit 6) “4” of the hexadecimal digit 7) “3” of the hexadecimal digit 8) “Validate”
Key Type / Status Label
Two Hexadecimal Labels
"Validate" Label For example, to configure the Prefix Code to be “AB”, the “Prefix Code” label is first read, and then the hexadecimal digit labels “4”, “1”, “4”, and “2” are read, and finally, the “Validate” label to complete the setting. 10.4.3 Key Type/Status Setting The key type/status is specified in character basis. Each character programmed is by default of Normal key type. A character of normal key type can have associate status settings (add Shift/Control/Alternate). Whereas a character of Scan Code type may not have any associate key status settings.
Note: In internal representation, characters that are specified with either scan code or associate key status, occupy two normal characters each. So the maximum number of characters can be configured for a string parameter will decrease, if these character specifications are used. 10.5 Exit Configuration Mode Both the “Update”, and the “Exit Setup without Changes” labels will exit the scanner from configuration mode when they are read. These two labels differ in whether to keep the new settings on the scanner or not, as their names suggest. The scanner will respond with 6 beeps and restart itself, if either label is read.
• Normal Key Type: When this label is read, the scanner will assume the following hexadecimal digits are the ASCII code of the character being programmed. And it will also clear all the associate key status settings made to the current character. • Scan Code: When this label is read, the scanner will assume the following hexadecimal digits are the scan code value of the character being programmed. • Add Shift: The Shift key will be sent together with the character programmed.
43
44