Page 41

Symbology 33

Code-11 Read Disable ■

Enable

Checksum Verification Disable

One

Two ■

Checksum Transmission Disable ■

Enable

Spare

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

END

[Set ASCII Code]

Page 42

34 Symbology

MSI / Plessey Read Disable ■

Enable

Checksum Verification Disable

Mod 10 ■

Mod 10/10

Mod 11/10

Checksum Transmission Disable

Enable ■

Spare

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

[Set ASCII Code]

START

Page 43

Symbology 35

UK / Plessey Read Disable ■

Enable

Checksum Verification Disable

Enable ■

Checksum Transmission Disable

Enable ■

Spare

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

END

[Set ASCII Code]

Page 44

36 Symbology

IATA Read Disable ■

Enable

Checksum Verification Disable ■

Enable

Checksum Transmission Disable ■

Enable

Spare0

Disable ■

Enable

Spare1

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

[Set ASCII Code]

START

Page 45

Symbology 37

Telepen Read Disable ■

Enable

Format

Numeric Mode ■

ASCII Mode

Auto Mode

Checksum Verification Disable

Enable ■

Checksum Transmission Disable ■

Enable

Spare

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

END

[Set ASCII Code]

Page 46

38 Output Control

Output Control Preamble Transmission Disable ■

Enable

Data0 <‘NULL’>

(Range: 0016-FF16)

[Set ASCII Code]

Data1 <‘NULL’>

(Range: 0016-FF16)

[Set ASCII Code]

Post amble Transmission Disable

Enable ■

Data0 <‘CR’>

(Range: 0016-FF16)

[Set ASCII Code]

Data1 <‘LF’>

(Range: 0016-FF16)

[Set ASCII Code]

Add-On Preamble Transmission Disable ■

Enable

Data 0 <‘CR’>

(Range: 0016-FF16)

[Set ASCII Code]

Data1 <‘LF’>

(Range: 0016-FF16)

[Set ASCII Code]

Spare0 Disable ■

Enable

Spare1

Disable ■

Enable

START

Page 47

Output Control 39

Output Control Prefix Transmission Disable ■

Enable

Clear Prefix Data

(15 Bytes, Range: 0016-FF16)

Data <‘NULL’>

[Set ASCII Code]

Suffix Transmission Disable ■

Enable

Clear Suffix Data

Data <‘NULL’>

(15 Bytes, Range: 0016-FF16)

[Set ASCII Code]

Code ID Transmission Disable ■

Enable

Code ID Position

Before Code ■

After Code

Code Name Transmission Disable ■

Enable

Code Length Transmission Disable ■

END

Enable

Page 48

40 Specific Adjustment

Specific Adjustment Specific Adjustment Beep Loudness

(Range: 0110-1010, Unit: Level)

[Set Value]

Beep Tone

(Range: 1010-5010, Unit: 100Hz)

[Set Value]

Beep Duration

(Range: 0110-9910, Unit: 10ms)

[Set Value]

Stand-By Timer

(Range: 0110-9910, Unit: 1s)

Active Timer

(Range: 0110-9910, Unit: 10ms)

[Set Value]

Sleep Timer

(Range: 0110-9910, Unit: 10ms)

[Set Value]

Good-Read Delay Timer(Range: 0110-9910, Unit: 10ms)

[Set Value]

[Set Value]

Double Confirm Times (Range: 0110-1010)

[Set Value]

Global Min. Code Length (Range: 0110-9910)

[Set Value]

Global Max. Code Length (Range: 0410-4810)

[Set Value]

Spare0

Spare1

START

Page 49 read from a scan by OCR; it may hold reading errors

Appendix 41 pT Appendix evo TAMIYA TAA

Page 50

42 Cable

Cable Type IBM PC, XT, AT & PS/2 Function 5p Din (M) 5p Din (F) 6p Mini Din (M) 6p Mini Din (F) Clock (Host) 1 --1 --Data (Host) 2 --5 --Clock (KBD.) --1 --1 Data (KBD.) --2 --5 GND 4 4 3 3 GND Shield 4 4 3 3 VCC (+5V) 5 5 4 4 4 5

3 2 1

3 2 1

4 5

5 3 1

5p Din (M)

5p Din (F)

Function RST (Host) Data (Host) GND GND Shield VCC (+5V)

Macintosh 4p Mini Din (M) 2 1 4 4 3

5p Mini Din (M)

3 1

4 2

4p Mini Din (M)

4 2

6p Mini Din (F)

4p Mini Din (F) 2 1 4 4 3 3 1

8p Mini Din (F) ----1 5 4 3 2 2 8

6

7

7

6

4 3 1

8 5 2

8 5 2

4 3 1

8p Mini Din (M)

6 4 2

4p Mini Din (F)

NEC 9801 8p Mini Din (M) 4 3 1 5 ----2 2 8

Function Ready (Host) Data (Host) Reset (Host) Retry (Host) Ready (KBD.) Data (KBD.) GND GND Shield VCC (+5V)

6 4 2

8p Mini Din (F)

5 3 1