Page 31

Symbology 23

Code-39 Spare Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID (Range: 0016-FF16)

[Set ASCII Code]

END

Page 32

24 Symbology

Interleaved 2 of 5 Read Disable ■

Enable

Format

Standard ■

Odd Scode

Checksum Verification Disable ■

Enable

Checksum Transmission Disable ■

Enable

Spare

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

[Set ASCII Code]

START

Page 33

Symbology 25

Industrial 2 of 5 Read Disable ■

Enable

Checksum Verification Disable ■

Enable

Checksum Transmission Disable ■

Enable

Spare

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

END

[Set ASCII Code]

Page 34

26 Symbology

Matrix 2 of 5 Read Disable ■

Enable

Checksum Verification Disable ■

Enable

Checksum Transmission Disable ■

Enable

Spare

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

[Set ASCII Code]

START

Page 35

Symbology 27

China Post 2 of 5 Read Disable ■

Enable

Checksum Verification Disable ■

Enable

Checksum Transmission Disable ■

Enable

Spare

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

END

[Set ASCII Code]

Page 36

28 Symbology

Codebar / NW7 Read Disable

Enable ■

Start/End Symbol Types ABCD/ABCD ■ abcd / abcd

ABCD/TN*E abcd / tn*t

Start/End Transmission Disable ■

Enable

Checksum Verification Disable ■

Enable

Checksum Transmission Disable ■

Enable

Spare

Disable ■

Enable

START

Page 37

Symbology 29

Codebar / NW7 Truncate Digits Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

END

[Set ASCII Code]

Page 38

30 Symbology

Code-128 Read Disable

Enable ■

Format

Standard ■

UCC/EAN-128

Append Function

Disable ■

Enable

Checksum Verification Disable

Enable ■

Checksum Transmission Disable ■

Enable

Spare

Disable ■

Enable

START

Page 39

Symbology 31

Code-128 Truncate Digits Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

END

[Set ASCII Code]

Page 40

32 Symbology 7

Code-93 Read Disable ■

Enable

Append Function

Disable ■

Enable

Checksum Verification Disable

One

Two ■

Checksum Transmission Disable ■

Enable

Spare

Disable ■

Enable

Truncate Digits

Leading Digits (Range: 0010-1510)

[Set Value] Ending Digits

Code Length

Min. Code Length (Range: 0010-4810)

[Set Value] Max. Code Length

Code ID

ID

(Range: 0016-FF16)

[Set ASCII Code]

START