Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 3

User's Manual Pocket Terminal PHL1300 Cradle IRU1300, pages 17 to 24

Pages 17 to 24 of 24

The original document is the PDF (413 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Opticon PHL-1300

Page 17

USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE

3 5

PIN-OUT

5.1 RS232 cable for cradle 1

1

9

9

RS232 cable

DB 9 DB 9 male Signal female (cradle) (PC) 3 2 6+1 5 4 8 7

TxD RxD DSR GND DTR CTS RTS

Signal In/Out Note (cradle)

2 3 4 5 6+1 7 8

RxD TxD DTR GND DSR RTS CTS

OUT IN OUT OUT not used ON (fixed) not used ON (fixed)

5.2 RS485 cable for cradle network

Network cable RS485

1

1

6

6

Modular plug (6P6)

Modular plug (6P6)

Signal

1 2 3 4 5 6

2 3 4 5 -

RD+ RDSD+ SD-

17

Page 18

USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE

6.1.2 Optical specifications

3 6

Light source

650 nm visible laser diode

Scan rate

100 scans/sec

Decode rate

100 decodes/sec

Reading width min. 40 mm.

Resolution at PCS 0,9 : 0.15 mm (6mil)

Min. PCS Values 0.45

SPECIFICATIONS

6.1 SPECIFICATIONS TERMINAL

Depth of field

6.1.3 Supported symbologies Chinese Post 2of5 Codabar incl. ABC and CX Code 39 Code 93 Code 128 EAN-8 incl. +2,+5 EAN-13 incl. +2,+5 IATA Industrial 2of5 Interleaved 2of5 Italian Pharmaceutical Laetus Matrix 2of5 MSI/Plessey UK/Plessey S-Code Telepen UPC-A incl. +2,+5 UPC-E incl. +2,+5

6.1.1 Electrical specifications Main battery

Lithium-Ion rechargeable (Opticon item) Alkaline AA-size batteries (optional user item)

Main battery operating time

Li-Ion: When making every 5 seonds 1 scan with 1 sec laserbeam on and 0.2 sec. green LED on and 0.2 sec. buzzer on, operating time is: approx. 36 hours Alkaline: When making every 5 seonds 1 scan with 1 sec laserbeam on and 0.2 sec. green LED on and 0.2 sec. buzzer on, operating time is: approx. 78 hours Different operation conditions affect the operating time

Backup battery

Lithium CR2032

Backup battery operating time

3 weeks backup time

Battery management

Low voltage indicated on the terminal display. When battery is low the switches off automatically.

Charging method Recharging Lithium-Ion pack in terminal via cradle

18

70 - 380 mm (at PCS 0.9, res. 1.0 mm)

6.1.4 Functionality Memory

ROM: 32 kB FlashROM:(O/S and program) 2 x 256 kB (total 512 kB) fast RAM: 2 kB RAM (data storage): 8 MB battery backed up D-RAM

Microprocessor

16-bit

Real time clock

Quartz RTC, time and date programmable, leap year handling, (accuracy + 60 sec./month)

Display

96x64 Pixels graphic LCD with backlight Character fonts: 5/10 lines x 16 characters

Page 19

USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE

Keyboard

Programming

19 keys total (18 keys user definable) Alpha/Numeric mode Functionality is provided by user application. The application may be downloaded from PC via cradle.

Interfaces

RS232 supported by cradle IrDAsupported on terminal RS485 supported by cradle

Transmission speed

Baudrate: 2400 - 115200 bps

6.1.5 Environmental specifications Temperature

-10 - + 40 oC in operation -20 - + 60 oC in storage

Humidity (non condensing)

20 - 80 % in operation 20 - 90 % in storage

Shock: drop:

1.5 m drop onto concrete surface

Shock: vibration: 10 - 50 Hz with 1G for 30 min, cycle for X,Y,Z. Ambient light rejection fluorescent 3.000 lux max. direct sun 50.000 lux max.

Emission

According to EN50081, part 1

Immunity

According to EN50082, part 1

Safety, Laser class

According to IEC825, Class I laserproduct

6.1.6 Physical specifications Dimensions

(l x w x d) 132 x 55 x 33 mm

Case material

ABS

Weight body (incl. battery): ca. 170 g (depending on battery type)

6.2 SPECIFICATIONS CRADLE 6.2.1 Electrical specifications Power supply

9V DC

Battery charging time when battery in terminal: 8 hours charge

6.2.2 Functionality Interfaces supported

RS232 RS485

Serial communication

RS232 Baudrate: 1200 - 115200 RS485 Baudrate: 1200 - 115200

Transmission modes

Half duplex RS232 Half duplex RS485

Parity

Odd, Even, None

6.2.3 Environmental specifications Temperature

0 - 40 oC in operation -20 - 70 oC in storage

Humidity (non condensing)

30 - 85 % in operation 30 - 90 % in storage

Shock: vibration:

10 - 50 Hz with 1G for 30 min, cycle for X,Y,Z.

Emission

According to EN50081, part 1

Immunity

According to EN50082, part 1

6.2.4 Physical specifications Dimensions

(l x w x h) 134 x 78 x 75 mm

Case material

ABS

Standard connector

RS232 - D Sub 9P Female RS485 - 6 pins modular plug

19

Page 20

USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE

3 7

TROUBLE SHOOTING

This chapter contains information on solving problems you may encounter when using the terminal and/or cradle. If problems occur, first carry out some general checks, before verifying the problem with the descriptions in this chapter.

General checks: Make sure everything is installed properly Check the power supply of all devices Is the reading window of the terminal clean? Is the optical window of the cradle clean? Are the bar code labels readable, eg. not damaged or poorly printed?

If the equipment still does not work after these checks have been performed, please verify if one of the problems described in this chapter applies to the problem you have with the scanner. It is possible that you may not solve the problems, despite our descriptions. In this instance, please contact your dealer or Opticon. When the terminal needs to be repaired, please ensure that the label with the serial number is still present. If sending the terminal or cradle, please use the original packing to minimise the chances of damage.

20

Page 21

USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE

7.1 COMMUNICATION PROBLEMS

No communication from the cradle to the device, or data is transmitted distorted or corrupted.

7.2 READ OPERATION PROBLEMS

When the terminal has a problem with reading the label: ?

?

?

Power indicator of the cradle is not green. Check if the battery case cover of the PHL1300 is closed properly. Clean the optical interface window of the cradle and/or terminal, and try again. Check all cables. When the power indicator is still not green, the cradle needs service.

No data transmitted The cradle will only work if connected to a PC. Clean the optical interface window of the cradle and/or terminal, and try again.

?

?

? ?

Data is corrupted, or no data is transmitted. Is the proper baudrate selected? The computer needs the same baudrate as the terminal. Clean the optical interface window of the cradle and/or terminal, and try again.

?

?

The terminal looses data when the battery pack is removed for a short period. ?

The resolution of the bar code is too high. Decrease the distance between the bar code and the terminal.

The angle between the label and the terminal is too high. Change the angle between the bar code and the terminal.

The distance is too far or too close. Change the distance between the bar code and the terminal.

The bar code is larger than the laser beam. Try moving the terminal a bit further away from the bar code.

The read window is dirty. Clean the read window of the terminal.

The type of the bar code label is not enabled. Enable the bar code symbology in the application program.

The backup battery is empty. Replace the Lithium CR2032 battery by a new one.

21

Page 22

USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE

7.3 TERMINAL PROBLEMS

Terminal does not respond to key presses, while the display stays on. ?

?

Message “Application halted” or “No application installed” is shown. There is no user’s application for PHL1300 loaded in the terminal. Contact your supplier.

For example pressing the shift key does not toggle the shift indicator. There is a flaw in the application program. Disconnect the battery pack, and place it then back in. The terminal will be in off-state. Activate the system menu and restart the application, or download new application. If problems appears continously contact the supplier of the user’s application.

Laser stays off, when pressing the triggerkey. ?

?

22

Power is off. The triggerkey is no powerkey. Press the powerkey to get power. If the terminal is not used the scanner will switch off all functions. Press the powerkey to reactivate.

Laser temperature has become too high. The laser is switched off automatically, when thelaser temperature becomes above 50oC. Wait until the temperature has dropped.

Terminal gets no power, when pressing the powerkey. ?

The main battery is exhausted. Replace the battery pack, or charge the terminal in the cradle.

Terminal does still not operate and needs a service Send the terminal to your supplier for service, paying attention to the limited warranty.

Page 23

USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE

3 8

PRODUCT ORDERING INFORMATION Article Code

TERMINAL PHL1300 PHL-1300

Article Code CRADLE IRU1300

A73900R0020

IRU-1300

ADDITIONAL EQUIPMENT

ADDITIONAL EQUIPMENT

Battery pack for terminal Rechargeable battery pack LBP-1300

Power supply Cable RS232 DB9F AT adapter 09M-25F Cable RS485

ORBLIOP0020

A74030N0020

A50200N0020 O2520000020 P10AT000040 O2520000050

Software development tools Microtec ANSI-C cross compiler O8010000010 C-library for Opticon terminals D4030000020 Application Generator Potstar, Limited version D6010000010 Application Generator Potstar, Professional version D6020000010

23

Page 24 read from a scan by OCR; it may hold reading errors

OP TICON Opticon Article Code 00220000130

24