Page 9
USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE
2.3 HANDLING PRECAUTIONS
Use of the terminal Avoid temperature changes. Sudden temperature changes can cause condensation to form on the terminal. Using the terminal while condensation is present can cause malfunction. Always wait until the condensation clears naturally before attempting operation.
To avoid malfunctioning and to ensure years of trouble free operation, pay attention to the following: General use Do not use or leave the product in extremely hot areas - like direct sunlight, near a heater, or in a car - or in areas that are very cold, humid, moistured or dusty.
Do not leave the terminal in an area where static charge is accumulated, or near devices where electromagnetic emission is generated.
Do not expose the product to rain or water splash. Do not subject the the product to very strong impact, do not throw or drop the terminal from large heights.
!
!
Do not allow a mechanical shock to the product.
Cleaning instructions Clean the exterior by wiping it with a soft, dry cloth. Do not use much water. Do not use thinner, white spirit or other solvents. These can discolour the case and the keys and has a negative effect on the lifetime of the keys. Cleaning of the terminal Clean the optical interface window periodically. Cleaning of the cradle Avoid touching the contacts in the cradle. The contacts must stay as clean as possible to maintain optimal charging capacity. Do not use water when cleaning the cradle. This can cause malfunction in the chargers.
Do not place any objects on top of the terminal. Do not lay the terminal face down. Doing so can cause accidental operation of the [PW] key or [ENTER] key, which can discharge your batteries or change settings you do not want to be changed.
Use of the cradle Do not place any other product than the PHL-type terminal in the cradle.
Maintenance There are no user-serviceable parts inside the terminal or the cradle. So do not try to take it apart. The manufacturer will not be liable for any damage caused by the customer. In case of malfunction that can not be solved by the trouble-shooting instruction in the appendix, please consult our service department.
9
Page 10
USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE
2.4.2 Cradle
2.4 ASSEMBLY
Place for mounting Follow the next steps to make your terminal ready for installation in a system, that is described further in the manual.
2.4.1. Terminal
Place the cradle in normal office conditions. Avoid a place under strong light. Otherwise IrDA communication may be disturbed.
To avoid drop use the hand strap. Power Connection Fix the small cord of the strap around the pillar of the terminal (ref. 1) Insert the handle of the strap in the thin loop (ref. 2) The strap is fixed to the terminal (ref. 3) Hold the handstrap around the wrist when carrying the terminal (ref. 4) !
Do not swing the terminal around.
Attach the DC jack of the AC adapter into the socket of the cradle. Then connect the AC adapter to the mains outlet When the terminal PHL1300 with the rechargeable battery pack is placed in the cradle, the LED on the cradle turns green. When the terminal PHL1300 with penlite batteries is placed in the cradle, no indication is given by the cradle.
2.4.3. Terminal on cradle
1
2
3
4
Start with a full battery To be sure of proper operation, it is advised to start with a full battery, charge the battery pack according to the instructions in the next chapter. Click the battery pack into the terminal, as instructed in the next chapter.
10
Take notice that the IRU1300 cradle is designed for the PHL1300 terminal. No other types of terminals can be placed into this cradle.
Page 11
USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE
2.5 INSTALLING, REPLACING AND CHARGING BATTERIES Wrong use of batteries might cause serious damage to the terminal or to the cradle. In order to avoid damage it is very important to take notice of the instructions.
!
!
!
!
Insert full batteries before use of the terminal. Never remove the main battery pack while the terminal is turned on. Doing so can cause data in the terminal to be deleted. Never change the main battery pack while the backup battery is out. Doing so can crash the application. When you do not use the terminal for a long time, make sure the main battery has enough capacity. When there is not enough capacity in the main battery the backup battery can not be charged and will become too low.
!
!
!
!
Only use recommended batteries. When other batteries are used, defects or other problems can occur. Before installing (new) batteries, please make sure you are using the recommended batteries. Do not make a mistake regarding the polarity (+ , -) of the battery. The terminal will not work when the polarity is incorrect. Use the right charger for batteries The rechargeable Li-Ion battery pack of Opticon can be charged in the cradle IRU1300 when it is in the terminal. Other rechargeable batteries need to be recharged in a separate battery charging device. Follow the instructions for installing, changing and removing the batteries very strictly. The products are not warranted for damage, defects, malfunction or loss of data, resulting from incorrect use of batteries.
11
Page 12
USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE
2.5.1 Required batteries
2.5.5 How to (re)place the main battery in the terminal?
The terminal needs both main battery and backup battery for operation.
!
Main Battery The main battery can consist of: Rechargeable Opticon battery pack (Li-Ion), to be recharged when placing the terminal PHL1300 in the cradle IRU1300. This battery is supplied with the terminal and is recommended by Opticon. Pen lite batteries. Batteries that are not supplied by Opticon must be AA-size and absolutely leakproof. If rechargeable batteries are used, they need to be recharged by a separate battery charging device.
!
Backup Battery Use only one type of battery for backup: Backup cell: CR2032 Li (Lithium, button type).
2.5.2 How to charge the rechargeable battery pack in the cradle? Make sure that the Opticon rechargeable battery pack is inserted in the terminal. If the terminal with the battery pack is placed in the cradle, the LED on the cradle will turn green. When the terminal is placed in the cradle, the rechargeable battery pack will be charged automatically for 8 hours.
2.5.3 When to replace or recharge the main battery? There are 2 reasons for replacing the main battery; as soon as possible after the battery indicator appears on the display. when you are not using the terminal for an extended period.
2.5.4 When to replace the backup battery? When low battery mark appears, replace the battery without delay.
12
Only use batteries as specified in paragraph 2.5.1. If you have data stored, make sure the backup battery is placed and full enough, to avoid data loss.
Unlock main battery case cover: (ref. 1) Unlock the case cover by use of a flat screwdriver or a coin. Remove old battery by simply taking out. Installing Opticon battery pack: (ref. 2) Follow the instructions on the label. Installing penlite batteries: (ref. 3) Make sure you use the right battery size. Place 2 batteries in the battery holder aligning plus (+) and minus (-) ends as shown inside the battery compartment. Lock main battery case cover: Position the case cover and fix its position by screwing hand tight.
Page 13
USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE
2.5.6 How to (re) place the backup battery in the terminal? !
!
Make sure that the main battery is full enough while changing the backup battery. Only use CR2032 Li (Lithium, button type) battery.
Unlock backup battery case cover: (ref. a) Unlock the case cover by use of a small crosshead screwdriver or swatch screwdriver. Remove old battery by simply taking out. Installing backup battery: (ref. b) Make sure that the positive side of the battery is pointed upwards (visible) and place it in the compartment. Lock backup battery case cover: Position the case cover and fix its position by screwing hand tight.
1
2 a b
3
13
Page 14
USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE
2.6 INSTALLING IN A SYSTEM !
!
!
!
Exercise caution at all times when working with AC-powered equipment. Turn off your devices before installation. Because of the special pin-out of the connectors, use the cables supplied by the manufacturer. When you need another cable for a certain device, that is not supplied, contact your supplier to purchase the right cable. In case another cable is used, take notice of the pin-out specifications further in this manual.
2.6.1 Single cradle DB25 / DB9 HOST
DB9 CRADLE
RS 232
Connection sequence for single cradle: Place the cradle in normal office conditions, avoid a place under strong light. Disconnect the power supply. Set the required DIPswitches for baud rate and function. Connect the interface cables. Connect the power supply. Place the PHL1300 terminal in the cradle.
Connection sequence for cradle network: Set all cradles to the same baud rate (by DIPswitch) Only 1 cradle in the network will be connected to the PC through one RS232 cable. On this cradle the DIPswitch for RS232 connection must be enabled. Through this connection all cradles can communicate to the PC. A maximum of 16 cradles can be connected in a network through RS485 cables. For the cradles that are not directly connected to the PC the DIPswitch for RS232 connection must be set to off. The first and the last cradle in the network must have the termination resistors set by dipswitch.
2.6.2 Cradle network
TRANSMISSION HOST
RS 232 TERMINATED RS 485 sw 1 = on sw 2 = on sw 3 = on
14
RS 485 sw 1 = off sw 2 = off sw 3 = off
//
RS 485 TERMINATED sw 1 = off sw 2 = on sw 3 = on
Page 15
USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE
2.6.3 DIP switch settings on cradle Setting the DIP switches on or off will result in differrent baudrates and enabled or disabled functions of the cradle. Open the cover of the DIP switches on the bottom of the cradle in order to reach the DIP switches. Turn the DIP switch ON by moving it upwards into the direction of the dipswitch number. Turn the DIP switch OFF by moving it downwards into the direction OFF.
3 3
OPERATION OF THE TERMINAL
The functionality of the terminal is determined by software, the so-called user application, that is running on the terminal. Usually, the terminal is not equipped with software and has no functionality. At first the user application must be loaded before the terminal can be used for barcode scanning.
DIP SWITCH
FUNCTIONS
ON
OFF
DEFAULT
SW 1
RS 232 CONNECTION in use not in use
ON
SW 2
RS485 TERMINATOR in use not in use
OFF
SW 3
RS485 TERMINATOR in use not in use
OFF
SW 4
BAUDRATE *
--
--
OFF
SW 5
BAUDRATE *
--
--
OFF
SW 6
BAUDRATE *
--
--
ON
*) BAUDRATE
SW 4
SW 5
SW 6
1200
OFF
OFF
OFF
2400
ON
OFF
OFF
4800
OFF
ON
OFF
9600
ON
ON
OFF
19200 (default)
OFF
OFF
ON
38400
ON
OFF
ON
115200
OFF
ON
ON
AUTO (PC controlled)
ON
ON
ON
Tools for developing a user application on the PC for use on the terminal, as supplied by Opticon are: Application Generator PotStar (Limited or Professional) C language: Microtec ANSI-C compiler and C library for handheld terminals. The user application must be downloaded from the PC into the terminal. You can use the cradle or an infrared adapter for communication between the terminal and the PC. A program on the PC will send the user application to the terminal, where it is stored in FlashROM memory. When the functionality of the terminal is defined by the application it is ready for operation. In a typical application you will press the trigger key and scan a bar code label as described in the next chapter. Scanned data and data entered from the keyboard is stored in the terminal's RAM. The user application can use this data in subsequent steps. The collected data can be transmitted to the PC for further processing through the cradle.
15
Page 16
USER’S MANUAL PHL1300 TERMINAL / IRU1300 CRADLE
!
3 4 !
!
!
SCANNING
Fit the bar code in the laser beam from margin to margin and pass the scanner downward over the bar code, as shown in the scan position illustration.
Please take care of the handling precautions. Please make sure that the terminal is installed according to the installation instructions. Never remove the main battery pack while the terminal is turned on. Doing so can cause data in the terminal to be deleted or corrupted.
4.1 How to read the barcode The scanning sequence is defined by the user’s application. A typical sequence is: Press the [PW] key to turn power on. Check the display for the message: READ BAR CODE Point the terminal to the barcode and press the Trigger key. Point the laserbeam to barcode as shown in the scan position illustration. The barcode will be read and the reading results will be indicated. A ‘Good Read’ means that the scanner has effectively recognised and decoded the bar code. In most cases, the application program will provide an indicator signal or a buzzer signal to indicate a good read to the user. When the read is incorrect you can try again, paying attention to the instructions in this chapter.
16
The terminal is a Class I laser product conforming to the strictest laser safety standards. However, we recommend that you avoid looking directly into the laser beam emitter, or pointing the laser beam directly into someone’s eyes.
incorrect read scan positions good read scan position
When reading a small bar code, decrease the distance between the terminal and the bar code. For larger bar codes, position the terminal so that the bar code fits into the laser beam. When reading a very high density bar code, decrease the distance between the terminal and the bar code. For a low density bar code, increase the distance between the terminal and bar code.
4.2 Barcode reading problems When the barcode can not be read, try the following: Change the angle between the bar code and the terminal. Change the distance between the bar code and the terminal. If the bar code is larger than the laser beam, try moving the terminal a bit further away from the bar code.