The text of a manual · part 2 of 8
NFT 2100/2200 Miniature High Speed CCD Fixed Position Barcode Scanners User's Guide, pages 11 to 20
Pages 11 to 20 of 73
The original document is the PDF (332 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Opticon NFT-2100
Page 11
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Section 3 Positioning the Scanner for Optimum Performance Achieving Optimum Performance Four items greatly impact performance: 1) Distance (from the scan window) to the bar code 2) Field of View 3) Specular Reflection 4) Quality of Bar Code Labels 1) Distance to the Bar Code and 'Depth of field' The ideal location of the bar code relative to the scanner is at its focal distance, about 1.4" for the NFT2100 and 1.2" for the NFT220. A bar code located either too near or too far from the scanner will be out of focus for the scanner camera causing the scanner to have difficulty decoding what appears to be fuzzy bars and spaces. Just as with any camera, the scanner has a working depth-of-field (DOF). It can read bar codes that are not precisely at its focal distance - maybe a little closer, or a little farther away. The DOF varies based on the density of the bar code, i.e., the thicker the bars and spaces the more DOF. Very high density bar codes (which have very narrow bars) are readable over a much shorter DOF range than low density bar codes with larger bars. The following table shows the depth-of-field “specifications” (closest to farthest reading distances) for the NFT2100/2200 scanner. The actual performance may differ slightly from unit to unit. Also, it is important to note that this data was measured under ideal conditions using high quality bar code labels. In a “real world” environment the conditions will not be as ideal. Therefore, the best practice is to position the scanner near the center of the depth-of-field rather than at the extremes of its depth-offield. Depth-of Field NFT 2100 * Code Density
Min. Distance Max Distance (inches) (inches)
Depth-of Field NFT 2200 *
Range (inches)
Min. Distance Max Distance (inches) (inches)
Range (inches)
6 mil
0.9
1.6
0.7
0.7
1.4
0.7
10 mil
0.8
1.7
0.9
0.6
1.5
0.9
20 mil
0.8
2.0
1.2
0.6
1.8
1.2
40 mil
0.9
2.4
1.5
0.7
2.2
1.5
* measured from front edge of scanner
2) Reading width or Field of View of the scanner The table below shows the field-of-view (FOV) at various distances from the window. The FOV is the maximum width that the scanner is capable of reading. It is the distance from the left edge of the view to the right edge. For the NFT 2100 and the NFT2200, the FOV will be 3.1" at its focal distance of 1.4" and 1.2" respectively. Any part of a bar code label that is positioned outside of the FOV will make the label unreadable. Good design policy is to position the barcode at the center of the FOV where the camera sees best.
Page 11
Page 12
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Remember: The width of a bar code label includes not only the bars and spaces but also the required white space (quiet zone) on each end. Readable Width or Field of View (Field-of-View Specification Based Upon 69º Sweep) 1.0"
Focal Distance 1.4"
1.5"
2.0"
2.5"
25mm
35.4mm
38mm
51mm
64mm
0.8"
Focal Distance 1.2"
1.3"
1.8"
2.3"
20mm
31.4mm
33mm
46mm
58mm
2.6
3.1"
3.3
4.0
4.7
66mm
80mm
83mm
101mm
118mm
NFT2100
NFT2200
Field of View
3) Avoiding Specular Reflection Do not position the scanner at an angle that causes the LED light to be reflected directly back into the scanner. This is called specular reflection. Too much reflected light can “blind” the scanner preventing a good decode. For optimal performance we recommended skewing the scanner ±13º off the perpendicular to the barcode label surface. If the bar code label is located on a flat surface, specular reflectivity occurs in the region between ±10 degrees off perpendicular (See diagram). If the bar code label is located on a cylindrical surface, such as a test tube, the angle of specular reflection is measured tangent to the curve. If the curved surface is also moving, specular reflection may occur at some point along the movement. This is OK, as long as there is sufficient regions on the test tube label where the label is out of the specular angle. The following diagram indicates the region to avoid:
6.3 [0.25] 13°
10°
10°
14.5 [0.57]
Avoid This region Avoid This region
10°
13°
90°
10°
Preferred skew angle for NFT2100
Preferred skew angle for NFT2200 Page 12
Page 13
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
4) Quality Bar Code Labels The quality of the bar code label can affect the scanning performance. Poor quality labels are more difficult to decode and may result in non-reads or potential misreads. The bar code label should be printed to specifications. This means that the bars are printed within spec, with the correct widths, no ink spread, crisps edges and no voids. There should be a sufficient quiet zone on both ends of the bar code label. For best results, the paper or label stock should have a matte finish to diffuse light. The print contrast signal (which is a comparison of the reflectance of the bars and the background stock) should be as high as practical.
Measuring Scanner Performance A method for properly positioning the unit is to program the scanner for Trigger Disable (S7) and Continuous Read (S2) modes. The scanner will now be always on and will continuously read the same bar code. Since the buzzer sounds each time the bar code is read, the sound of the buzzer can be used like a “Geiger counter”. As the position of the scanner changes the sound of the buzzer will change. The buzzer sound will be loudest and most continuous at the best reading position.
Application Notes Tips for Achieving High Throughput In some applications your primary objective may be to achieve the highest possible throughput rate. The following list identifies the parameters and scanner settings that can maximize scanning and decode throughput speed. Note, by emphasizing maximum throughput, other areas of performance may be affected. For example, the number of non-reads could increase. If high throughput is critical, consider some or all of these settings: ♦
Operate in the Trigger Disabled mode. Operation of the trigger creates delay before decoding begins, slowing down throughput rate.
♦
Only enable those symbologies that you will be decoding.
♦
Eliminate all suffixes and prefixes to reduce transmission time.
♦
Minimize the number of redundant reads required before transmitting data.
♦
Transmit the decoded data at the highest baud rate.
♦
Disable buzzer functions.
Tips for Insuring Highest Data Integrity There are several parameters that can enhance your confidence that the correct bar code data is transmitted. Note that by emphasizing the accuracy and security of the data other areas of the scanner operation may be affected, for example, you may not achieve the highest throughput. If accuracy and data integrity are critical, consider some or all of these settings: ♦
Program the scanner to require a high number of redundant decodes prior to transmitting. For example, program the scanner to decode a bar code exactly the same way three consecutive times before transmitting the data. Then decoding the bar code the same way 2 out of 3 times or any 3 out of 4 times is not sufficient. It must obtain three consecutive, identical decodes.
♦
Utilize a predetermined, fixed-length of bar code. Program the scanner to only decode a bar code of that length. Bar codes of any other length will be ignored. Page 13
Page 14
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
♦
The quality of the printed bar code must be excellent.
♦
Use a bar code symbology that contains an internal check digit and program the scanner to calculate that check digit for validity prior to transmitting.
♦
Do not use a symbology with poor internal verification, or subject to partial decodes, such as 2 of 5 or MSI/Plessey.
♦
Only enable those symbologies that you will be decoding.
♦
Transmit data at low baud rates to minimize communication errors.
Tips for Verifying the Presence of a Bar Code If the scanner is operated in the “trigger enabled” mode and the trigger is activated, one of three conditions may occur: A bar code is scanned and decoded. A bar code is scanned but is not decoded (e.g., print quality was poor) No bar code is present
Decoded data is transmitted No data is transmitted No data is transmitted
In some applications, when no data is transmitted, it may be important to know why. Was there a bar code present that could not be decoded, or was no bar code present at all? This requirement is common in applications such as automated blood analysis equipment. Test tubes containing blood samples from many different people are loaded into a rack for automatic analysis. The bar code on each tube ties that sample and the results back to a specific individual. If no bar code data is transmitted it is critical to understand the reason. Your Opticon scanner, when operated in the Trigger Enabled mode, can be programmed to transmit an error message indicating whether or not a bar code was present. See Section 33 of Appendix C of this manual for details.
Page 14
Page 15
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Section 4 Configuring the Scanner Since the operation of the NFT2100/2200 scanners are microprocessor controlled, it is possible to modify or program its operation to match your specific application. Changes in parameter settings can be accomplished two ways. 1. The scanner can be programmed by sending software commands from the host PC to the scanner via the RS232 connection. Most commands will be immediately active, but are not stored into nonvolatile memory until the store command, Z2, is sent. A few commands, such as changing the communication parameters will not be active until they are stored via the Z2 command. 2. The second method employs specially designed programming bar codes referred to as menu commands. Scanning these bar codes instructs the scanner to modify specific parameters. These commands are stored into non-volatile memory as soon as the menu command mode is exited. Once stored in non-volatile memory, these settings will remain even after powering the unit OFF and ON.
Programming Menus & Commands Appendix A contains full instructions on how to configure the scanner as well as a complete listing of the computer commands and programming bar codes that are available to customize the scanner for your application.
Default Settings When you modify or change any parameters, the scanner can be programmed to retain the new parameter in non-volatile memory, even if power is interrupted or terminated. If for any reason the scanner is instructed to return all parameters to default settings (U2), it will return to the default settings shown in the following table.
%) throughout the bar codes menus.
Default settings are indicated by a pointing hand symbol ( Parameter RS 232 Communications Trigger Function Read Mode No. of Redundant Decodes UPC-A (12 digits) UPC-E (7 digits) Code 39 Codabar 2 of 5 (Interleaved & Industrial) Min/Max length of bar code only Buzzer Positive bar codes only Error indications Prefix Suffix
Factory Default Setting 9600 baud , 8 data bits, 1 stop bit, No parity No handshaking Disabled, (scanner is ON) Multiple Read Mode Read three times before transmitting No leading zero transmitted (EAN 1st Position) send check digit No leading zero transmitted Send check digit Do not calculate check digit/Transmit check digit Disable start/stop characters transmission (*.....*) Disable start/stop characters transmission Do not calculate check digit Do not calculate check digit Disabled Enabled Enabled Do not transmit error message none Carriage Return
Page 15
Page 16
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Section 5 Application Engineering Support Technical Assistance and Support Opticon is eager to help you integrate the NFT2100/2200 scanner into your application. Our technical support staff is available to answer any questions or work with you to adapt the scanner to your specific situation. We are happy to answer your questions, assist in configuring and positioning the scanner for optimum operation, and help resolve any problems you encounter. Call us at 1 (800) 636-0090, and ask for technical support.
Common Causes of Poor Performance The most common reasons for poor scanning performance are listed below: ♦
Bar codes are not positioned at the focal distance or in the "field of view" of the scanner.
♦
Specular reflection is impacting the scanner. Change the angle/position of the scanner or the bar code.
♦
Poor quality of printed bar codes. Bar codes are out of specification.
♦
The paper on which the bar code is printed is highly reflective or has a glossy finish causing light to be reflected into the scanner.
♦
The paper background is not white, but some color like dark blue, causing poor contrast.
♦
The distance from the scanner to the bar code is not suitable for the density of the bar code. Or the density of the bar code is beyond the scanners capability. If the red illuminating light of the scanner is not on, the scanner may be in the “Trigger Enable” mode expecting a trigger signal.
♦
If the com port setting is set to Handshaking, the scanner will not transmit until the CTS signal (RTS from Host) is activated.
Modified and/or Customized Scanners Opticon will work with you to modify or customize scanners to match your requirements. Scanners can be modified in terms of connector type, pin-outs, cable length, default settings, custom software and many other areas. Opticon will modify scanners in our factory and ship you scanners that match your specific requirements. By incorporating your modifications directly into production scanners, you receive scanners tailored for your need. They can be used immediately without the need for further modification or rework.
Page 16
Page 17
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Section 6 Scanner Labeling IEC 825-1 Class 1 LED Devices The NFT2100/2200 has been examined and found to be a CE Class 1 LED Device according to the relevant requirements of IEC 825-1 and corresponding EN 60825-1 (1993-11) including amendment 1 (1997-09) and amendment 2 (2001-01). The NFT2100/2200 scanner uses low-power visible LEDs. As with any very bright light source, such as a flashlight, you should avoid staring into the light. Momentary exposure to an IEC 825-1 Class 1 LED is not known to be harmful. A manufacturer’s label, as shown below, indicating the manufacturer, product model, ordering number, serial number, CE mark and place of manufacture is affixed to each scanner.
OPTICON NFT-2100-I-RS232C
Ordering Number xxxxxx
Serial Number ******
MADE IN JAPAN
Section 7 Scanner Servicing and Maintenance The NFT2100/2200 scanner contains no user adjustable or serviceable parts in the interior of the scanner. All product service must be performed by the Opticon Service Department in Orangeburg, NY. Opening the scanner will void the warranty. The NFT2100/2200 is warranted for 7 year including parts and workmanship. If you need warranty or out-of-warranty repair, first call 1-800-636-0090 to obtain a Returned Material Authorization (RMA) number. You will be provided a number and shipping instructions. There is no scheduled maintenance required for the NFT2100/2200. The scanner can be cleaned using a water dampened, lint free or lens cloth. Be careful to avoid excessive moisture that would penetrate the housing or obscure the window. While use of cleaning fluids other than water are not recommended, a neutral detergent or ethanol would be preferred if necessary. Do not use bleach at full or diluted strength as damage to the painted case and/or window may result.
Page 17
Page 18
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Appendices Appendix A
How to Program the Scanner
Appendix B
Computer Programming Commands
Appendix C
Bar Code Programming Commands
Appendix D
Dimensional Drawing
Appendix E
Optical Performance (typical)
Page 18
Page 19
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Appendix A Programming the Scanner Two different methods can be used to program parameters to configure the scanner: a. Programming via Computer Commands b. Programming via special Bar Codes from a menu page Most parameters can be programmed using either of these two methods. However, there are certain parameters that are only programmable via the bar code menu.
a. Programming via Computer Commands Parameters can be programmed by sending software commands or keyboard strokes from the host computer to the scanner in the following format: <ESC> Computer Command <CR> Note:
Only upper case letters are recognized, e.g., “AB” not” ab” Each command normally consists of two characters Downloading of software commands cannot be “grouped” together. Each command must be preceded by <ESC> or <STX> and followed by a <CR> or <ETX>
Parameters programmed by downloaded commands can be stored permanently by transmitting a “<ESC> Z2 <CR>” command. It is not necessary to send a “Z2” command after each parameter that is changed. One Z2 command will save all changes. Appendix B lists all of the Computer Commands. In Appendix C, Bar Code Programming Menus, the lefthand column in all menus contains the Computer Command associated with that bar code.
b. Programming via Bar Codes Use the following steps to program parameters via the bar code menus: 1. Scan the “Start/End” bar code. This instructs the scanner to enter the Programming Mode. While in this mode the scanner will beep intermittently. 2. Scan the bar code(s) associated with the desired parameter(s). The scanner will beep when the bar code is read. Note: because of the close proximity of bar codes on the page, it is important to aim carefully to ensure that only the desired bar code is scanned. 3. Scan the “Start/End” bar code. This instructs the scanner to exit the Programming Mode. All the parameters that were scanned are retained in non-volatile memory and are stored permanently (even if the scanners is powered down) or until they are changed again. When the scanner is in the Programming Mode, you can change more than one parameter at a time. However, this may become confusing. Until you become proficient at programming you may prefer to change only a few parameters at one time. We recommend that you keep a record of the changes you Page 19
Page 20
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner have made to the scanner. Note, while you are in the programming mode the scanner will not read regular bar codes.
What if you make a mistake? Don’t worry. If you are programming the scanner but are unsure of which parameters have been changed, scan the Reset All Defaults bar code. This bar code returns the scanner to the default settings that were installed in the factory at the time the product was manufactured. Scanning this bar code erases any changes you have made, including any changes that were made during previous programming. Reset All Defaults U2 Command This command will return all settings to the defaults that were installed in the factory
Page 20