The text of a manual · part 3 of 8
NFT 2100/2200 Miniature High Speed CCD Fixed Position Barcode Scanners User's Guide, pages 21 to 30
Pages 21 to 30 of 73
The original document is the PDF (332 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Opticon NFT-2100
Page 21
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Appendix B Computer Programming Commands All commands listed below must be preceded by an 'ESC' (x1B) or 'STX' (x02) character and be followed by a 'Carriage Return' (x0D) or 'ETX' (x03) character. Shaded areas indicate factory default settings. Enable
Disable
Global Defaults
U2
Enable Factory Default Settings
Z1
Transmit software version
Z2
Save all values set by command
Z3
Enable
Disable
Options for UPC-A and UPC-E
E2
UPC-A as EAN13 (13 Digits) Transmit leading zero & CD
E3
UPC-A (12 Digits) No leading zero but transmit CD
Transmit software setting flags, prefix/suffix, & min/max lengths.
E4
UPC-A as EAN13 (12 Digits) Transmit leading zero but No CD
Trigger ON/OFF
E5
UPC-A (11 Digits) No leading zero & no CD transmitted
Symbology Selection
E6
UPC-E (8 Digits)Transmit leading zero & CD
A0
Enable all symbologies
E7
B0
Disable all symbologies
UPC-E (7 Digits) No leading zero but transmit CD
J0
Enable all UPC and EAN plus add-ons
E8
UPC-E (7 Digits) Transmit leading zero but no CD
E9
UPC-E (6 Digits) No leading zero & no CD transmitted
Z
Only
Y
Add
A2
B2
Code 39
A3
B3
Codabar (NW-7)
A4
B4
IATA
A5
B5
Code 93
A6
B6
Code 128 (Inc. EAN-128)
A7
B7
MSI/Plessey
A1
B1
UK/Plessey
A9
B9
Telepen
J1
R1
UPC (A/E)
J2
R2
UPC (A/E)+2
J3
R3
UPC (A/E)+5
J4
R4
EAN (13/8)
J5
R5
EAN (13/8) +2
J6
R6
EAN (13/8) +5
J7
R7
2 or 5 Industrial
J8
R8
2 or 5 Interleaved
C0
C1
Enable Check Digit calculation
JD
JZ
TriOptic
D9
D8*
Enable Check Digit Transmission
RA
R9
SCode
D0
D1
Enable start/stop characters transmission (*…..*)
6P
6Q
Transmit UPC-E as UPC-A
Enable
Disable
6K
6J
EAN-13 Transmit CD
6I
6H
EAN-8 Transmit CD
IA
IB
Enable ISBN translation
HO
HN
Enable ISSN translation
Enable
Disable
Options for Code 39
Options for EAN-8 & EAN-13
8E
Enable read of 1 or more character lengths
8D
Enable read of 3 or more character lengths
-Y
Enables primary decode algorithms for Code 39, I & D 2 of 5, IATA, & Codabar
Page 21
Page 22
Manual No. 25-ULNFT2100-01; Nov., 2006
Enable
Disable
-Y
-X
Enable
Disable
Primary/Alternative Algorithm
Alternate decode algorithm no.1 for Code 39
-Z Enable
Options for Code 39 (cont)
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Disable
Options for Code 39 (cont.) Alternate decode algorithm no.2 for Code 39
.S
Options for IATA
4H
Do not calculate check digit
Options for IT Pharmaceutical
4J
Calculate CD (CPN + Form + Serial)
Enable
Disable
D6
D5
IT Pharmaceutical only
4I
Calculate CD (Form + Serial)
D7
D5
IT Pharmaceutical if possible
4K
Calculate check digit (all data)
DB
DA
Transmit Leading A
4L
4M
Transmit check digit
-Y
-X
Primary/Alternative Algorithm
Enable
Disable
Options for Codabar (NW-7)
HC
Enable 1 character read minimum
Enable
Disable
HB
Enable 3 character read minimum
JF
OF
EAN-128 Only
HF
Enable 5 character read minimum
MO
MP
Concatenation
F0
Do not transmit start/stop characters
F1
Transmit start/stop as ABCD/TN*E
Enable
Disable
F2
Transmit start/stop as abcd/tn*e
+V
+W
F3
Transmit start/stop as ABCD/ABCD
F4
Transmit start/stop as abcd/abcd
H8
H9
Transmit check digit
H6
H7
Calculate check digit
H4
HA
Enable ABC Codabar
H5
HA
Enable Cx Codabar
H3
HA
Enable Normal ABC & Cx Codabar
HH
HI
Intercharacter gap check
-Y
-X
Primary/Alternative Algorithm
Options Code 128/EAN 128
Options for Code 93 Concatenation
Setting the Number of Digits H1 length setting all symbologies
HK
Length setting on selected symbologies
HL
Minimum length setting on selected symbologies
HM
Maximum length setting on selected symbologies
H0
Disable length setting on all symbologies
Prefix
Suffix
Select Symbology for prefix/Suffix
Options for I 2 of 5 / SCode
RY
RZ
All codes
Enable
Disable
G1
G0
Calculate check digit
N1
N6
UPC-A
E0
E1
Transmit check digit
M0
O0
UPC-A +2 or +5
GE
Enable 1 character minimum
N2
N7
UPC-E
GF
Enable 3 characters minimum
M1
O1
UPC-E +2 or +5
GI
Enable 5 characters minimum
N3
N8
EAN13
Transmit S-Code as I 2 of 5
M2
O2
EAN-13 +2 or +5
GG
GH
Page 22
Page 23
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Prefix
Suffix
Select Symbology for prefix/Suffix
Direct Input ASCII Control Characters
N4
N9
EAN-8
Cmd.
Char.
Cmd
Char.
Cmd
Char.
M3
O3
EAN-8 +2or +5
5A
SPACE
5M
,
7A
[
M4
O4
Code 39
5B
!
5N
-
7B
\
M5
O5
Codabar (NW-7)
5C
“
5O
.
7C
]
M6
O6
Industrial 2 of 5
5D
#
5P
/
7D
^
Cmd.
Char.
Cmd
Char.
Cmd
Char.
Direct Input Miscellaneous Characters
Prefix
Suffix
Select Symbology for prefix/Suffix (cont.)
5E
$
6A
:
7E
_
5G
&
6B
;
7F
‘
M7
O7
Interleaved 2 of 5
5H
`
6C
<
9T
{
M8
O8
Code 93
5I
(
6D
=
9U
|
M9
O9
Code 128
5J
)
6E
>
9V
}
I8
I9
IATA
5K
*
6F
?
9W
~
N0
N5
MSI/Plessey
5L
+
6G
@
MB
OB
SCode
L8
L9
Telepen
MZ
PS
Preamble/Postamble
Communication Parameters
Direct Input Alpha/Numeric Characters
K0
150 baud
K1
300 baud
K2
600 baud
Cmd
Char.
Cmd
Char.
Cmd
Char.
K3
1,200 baud
Q0
0
0A
A
$A a
K4
2,400 baud thru thru thru thru thru thru
K5
4,800 baud
Q9
9
0Z
Z
$Z z
K6
9,600 baud
K7
19,200 baud
K8
38,400 baud
Direct Input ASCII Control Characters
L0
7 Data Bits
Cmd.
Char.
Cmd.
Char.
Cmd
Char.
L1
8 Data Bits
9G null
1K
VT
1V
SYN
L2
Parity = None
1A
SOH
1L
FF
1W
ETB
L3
Parity = Even
1B
STX
1M
CR
1X
CAN
L4
Parity = Odd
1C
ETX
1N
SO
1Y
EM
L5
1 Stop bit
1D
EOT
1O
SI
1Z
SUB
L6
2 Stop bits
1E
ENQ
1P
DLE
9A
ESC
1F
ACK
1Q
DC1
9B
FS
1G
BEL
1R
DC2
9C
GS
1H
BS
1S
DC3
9D
RS
I0
Unlimited wait for CTS from terminal
1I
HT
1T
DC4
9E
US
I1
100 mS wait for CTS from terminal
1J
LF
1U
NAK
9F
DEL
I2
200 ms wait for CTS from terminal
Communication Handshaking
Page 23
Page 24
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Communication Handshaking I3
400 mS wait for CTS from terminal
P0
No Handshaking
P1
Busy/Ready
P2
Modem
P3
ACK/NAK (1 sec timeout with error buzzer)
P4
ACK/NAK no response (100 ms timeout, terminates with good read buzzer)
ZG
XON/OFF
Selecting the Read Mode S0
Single Read Mode (Trigger must be Enabled, S8)
S1
Multiple Read Mode
S2
Continuous Read Mode
Scanner Timeout (Trigger Mode) Y1
1 second after triggering
Y2
2 second after triggering
Y3
3 second after triggering
Communication Delays
Y4
4 second after triggering
KA
No inter character delay
Y5
5 seconds after triggering
KB
20 ms intercharacter delay
Y6
6 second after triggering
KC
50 ms intercharacter delay
Y7
7 seconds after triggering
KD
100 ms intercharacter delay
Y8
8 seconds after triggering
Y9
9 seconds after triggering
YL
Read time x 10
Buzzer Operation T0
Volume = Maximum
T1
Volume = Upper mid-range
T2
Volume = Lower mid-range
T3
Volume = Minimum
W0
Disable Buzzer
W1
Enable buzzer at 3kHz
W2
Enable buzzer at 3kHz with 2.5kHz interval
W3
Enable buzzer at 3kHz with 4kHz interval
W4
Buzzer duration 0.10 sec
W5
Buzzer duration 0.20 sec
W6
Buzzer duration 0.40 sec
W7
Buzzer duration 0.05 sec
W8
Enable buzzer
Setting the Trigger Functions S7
Disable the trigger function (LED On)
S8
Enable the trigger function (LED OFF until the trigger is activated )
Z
Activate the trigger; turns the LEDs ON
Y
Terminate the trigger.
Y0
Scan time follows Hardware trigger active time. Can be terminated by sending the Y command
YM
Stays ON indefinitely after triggering. Must be terminated by sending the Y commands.
EAN/UPC Add On Wait Times XA
Add-on Wait Time - Disable
XB
Add-on Wait Time – 250 msec
XC
Add-on Wait Time – 500 msec
XD
Add-on Wait Time – 750 msec
S1 Multiple read reset time for same labels AH
Multiple Read Reset Time – 50 msec
AI
Multiple Read Reset Time – 100 msec
AJ
Multiple Read Reset Time – 200 msec
AK
Multiple Read Reset Time – 300 msec
AL
Multiple Read Reset Time – 400 msec
AM
Multiple Read Reset Time – 500 msec
AN
Multiple Read Reset Time – 600 msec
AG
Multiple Read Reset Time - Indefinite
Page 24
Page 25
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Quiet Zone Options YN
No margin check
YO
Margin check 1/7 nominal
YP
Margin check 2/7 nominal
YQ
Margin check 3/7 nominal
YR
Margin check 4/7 nominal
YS
Margin check 5/7 nominal
YT
Margin check 6/7 nominal
YU
Margin check normal
Redundant Decoding X2
Read bar code 3 times before transmitting
X3
Read bar code 4 times before transmitting
Xmit Error (Trigger Enabled Mode only) TH
User defined error message for no label
TI
User defined error message for no decode
TG
Clear error messages for no label, no decode
ACK/NAK response to Host transmissions WD
No response to command
WC
Response to command – OK=ACK, ERROR=NAK
Good Read LED Operation T4
Disable good read LED (GRL)
T5
GRL ON for 0.20 seconds after decode
T6
GRL ON for 0.40 seconds after decode
T7
GRL ON for 0.80 seconds after decode
Page 25
Page 26
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Appendix C: Bar Code Programming Menus & Commands Index 1. Global Default & Scanner Configurations....................................... 27 2. Symbology Selection .............................................................. 28-29 3. Add/Activate Specific Bar Code Symbologies ............................ 30-31 4. Delete/Deactivate Bar Code Symbologies...................................... 31 5. Options for UPC.......................................................................... 32 6. Options for EAN-8 & EAN-13........................................................ 33 7. Options for Code-39 & IT Pharmaceutical) ............................... 34-35 8. Options for Codabar (NW-7) ................................................... 35-37 9. Options for 2 of 5 (Including SCode) ............................................ 38 10. Options for IATA....................................................................... 39 11. Options for Code-128 & EAN-128 ................................................ 40 12. Options for Code-93................................................................... 40 13. Setting the Number of Digits....................................................... 41 14. Creating a Prefix and/or Suffix .................................................... 34 15. Setting Prefixes (Identifying the Symbology) ........................... 43-44 16. Setting Suffixes (Identifying the Symbology) ........................... 45-46 17. Direct Input of Numeric Characters ............................................. 47 18. Direct Input of Alpha Characters ................................................. 48 19. Direct Input of Alpha Characters (Lower Case)…………………………….49 20. Direct Input of Control Characters .......................................... 50-51 21. Direct Input Characters Miscellaneous .................................... 52-53 22. Communication Parameters ................................................... 54-55 23. Handshaking ........................................................................ 55-56 24. Buzzer Operation ....................................................................... 57 25. Setting the Trigger Functions ...................................................... 58 26. Selecting the Read Mode ....................................................... 58-59 27. Add-on Wait Mode ..................................................................... 60 28. Scanner Timeout (Trigger Enabled Mode only) ............................. 61 29. Multiple Read Reset Time ........................................................... 62 30. Quiet Zone Options .................................................................... 63 31. Redundant Decoding.................................................................. 64 32. Transmitting Error Indications (Trigger Enabled only) ................... 64 33. Programming No Read Error Messages ........................................ 65 34. Good Read LED Operation .......................................................... 65
Page 26
Page 27
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
1. Global Default & Scanner Configurations Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
U2
Return all parameters to Default settings
V3
Z1
Transmit software version
[2
Z2*
Save all values set by com port commands (not lost upon power off)
[3
Z3
Display software settings, prefix/suffix, & min/max lengths
[!
%
Note: Where computer commands appear in parenthesis, bar code commands must be used to start and end manual programming of the scanner. Note: Scanner default settings are indicated by a pointing hand (%) symbol throughout the menus to follow. * Use Z2 (Save all values set by command) after sending com port commands to store settings in nonvolatile memory prior to power off.
Page 27
Page 28
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
2. Symbology Selection Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
A0
Enable all bar code symbologies
B1
J0
Enable all UPC and EAN
K1
A2
Only Code-39
B3
A3
Only Codabar (NW-7)
B!
A4
Only IATA
B5
A5
Only Code-93
B6
A6
Only Code-128 (Inc. EAN-128)
B7
A7
Only MSI/Plessey
B8
A1
Only UK/Plessey
B2
A9
Only Telepen
B:
J1
Only UPC (A/E)
K2
J2
Only UPC (A/E)+2
K3
J3
Only UPC (A/E)+5
K! CONTINUED ON NEXT PAGE…
Page 28
Page 29
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
2. Symbology Selection (continued) Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
J4
Only EAN (13/8)
K5
J5
Only EAN (13/8) +2
K6
J6
Only EAN (13/8) +5
K7
J7
Only Industrial 2 of 5
K8
J8
Only Interleaved 2 of 5
K9
JD
TriOptic
KE
RA
SCode
SB
Page 29
Page 30
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
3. Add/Activate Specific Bar Code Symbologies Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
B2
Enable Code 39
C3
%
B3
Enable Codabar (NW-7)
C!
%
B4
Enable IATA
C5
%
B5
Enable Code 93
C6
%
B6
Enable Code 128
C7
%
B7
Enable MSI/Plessey
C8
%
B1
Enable UK/Plessey
C2
%
B9
Enable Telepen
C:
%
R1
Enable UPC (A/E)
S2
%
R2
Enable UPC (A/E) +2
S3
R3
Enable UPC (A/E) +5
S!
R4
Enable EAN (13/8)
S5
R5
Enable EAN (13/8) +2
%
S6 CONTINUED ON NEXT PAGE…
Page 30