Page 1
NFT 2100/2200
Miniature High Speed CCD Fixed Position Barcode Scanners
User’s Guide Manual No. 25-ULNFT2100-01
Page 2
Contents Section 1 Introduction and Getting Started Product Overview Quick Start-Up Procedure
4 4 4
Section 2 Technical Specifications Physical Specifications Symbologies Supported Optical Specification Pitch Skew Tilt (rotation) Curvature Electrical Specification RS232 Communications Specifications Connector Pin Outs Environmental Specifications Ordering Information
6 6 6 6 7 7 8 8 9 9 10 10 10
Section 3 Positioning the Scanner Achieving Optimum Performance Measuring Scanner Performance Application Notes Tips for Achieving High Throughput Tips for Insuring Highest Data Integrity Tips for Verifying the Presence of a Bar Code
11 11 13 13 13 13 14
Section 4 Configuring the Scanner Configuring the Scanner Programming Menus & Commands Default Setting
15 15 15 15
Section 5 Application Engineering Support Technical Assistance and Support Common Causes of Poor Performance Modified and/or Customized Scanners
16 16 16 16
Section 6 Scanner Labeling
17
Section 7 Scanner Servicing and Maintenance
17
Appendix A How to Program the Scanner
19
Appendix B Computer Programming Commands
21
Appendix C Bar Code Programming Commands
26
Appendix D Dimensional Drawings
66
Appendix E Optical Performance (Typical)
68
Appendix F Placement Drawings
69
Appendix G Placement Drawings for Test Tubes
71
Page 3
Organization of this Manual This manual provides the necessary instructions for installing and using the Opticon NFT2100/2200 Fixed Position Scanners. The manual is organized as follows:
Section 1
Introduction and Getting Started Describes the general operation of the NFT2100/2200 Scanners. Also provides a Quick Start-Up Procedure that allows you to begin using the Scanners immediately.
Section 2
Technical Specifications Provides complete specifications, including mechanical details, optical performance, RS232 communications and other technical data.
Section 3
Positioning the Scanner for Optimum Performance Provides detailed instructions and tips for mounting and positioning the scanning to obtain the best scanning performance. Application Notes describe guidelines for maximizing specific characteristics.
Section 4
Configuring the Scanner Describes how various parameters can be programmed to customize the scanner for your specific application.
Section 5
Application Engineering Support Discusses the most common questions and concerns when adapting the NFT2100/2200 Scanners in your application.
Section 6
Scanner Compliance Discusses the various labels on the product required by CE.
Section 7
Scanner Servicing and Maintenance Discusses maintenance and cleaning procedures.
Appendix A How to Program the Scanner Appendix B Computer Programming Commands Appendix C Bar Code Programming Commands Appendix D Dimensional Drawings Appendix E Optical Performance
Page 4
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Section 1 Introduction and Getting Started Product Overview The NFT2100/2200 Fixed Position Scanners are a miniature, 200 scan per second, CCD barcode reader designed to be easily incorporated into host equipment. The small physical size makes the scanner easy to integrate into any hardware design. The NFT2100 with it's front view case and the NFT2200 with it's side view case allows for versatility in mounting options. Durability and reliability are assured. Advanced microprocessor technology coupled with Opticon’s proven decoding algorithms result in high speed operation with superior accuracy. These scanners are fully programmable allowing the user to customize parameters including changing communication settings, selecting symbologies, adding prefixes and appending suffixes. Programmable settings can be downloaded from the host CPU or computer directly to the scanners. These scanners are encased in a compact, rugged, yet lightweight steel enclosure. The compact size permits installation in the tightest areas allowing great flexibility in mounting and positioning the for optimum performance.
Quick Start-Up Procedure This section is for those who wish to start using the scanner before reading the complete manual. In only a few steps the scanner will be operable. Turn off the power to your PC and connect the scanner to a RS232 communications port. Note: You must provide +5 Volt DC power to the scanner. If you are using our standard LHA2107RR1S-054, you can utilize power supply, P/N 32-00907-01, by plugging its connector directly into the power jack on the DB9 connector. If the power supply is obtained from another source verify that it is identified with the CE mark. Turn on the power to the PC. 1) If you are operating in a Microsoft Windows 95/98/ 2000/ XP environment, you can set the communication parameters using Hyper Terminal as follows: ♦
Open Hyper Terminal. This can be done from Start→Programs→Accessories/ Communications
♦
Select Hypertrm.exe to create a New Connection
♦
In the Connection Description dialog screen enter a name for the new file, like "Opticon". If desired, select an Icon. Click OK
♦
In the Connect To (Phone Number) dialog screen, in the box entitled: Connect using. select the communication port, for example, “Direct to Com 1” Click OK
♦
In the Com 1 Properties screen, enter the appropriate Port Settings: Bits per second = 9600, Data bits = 8, Parity = None, Stop Character = 1, Handshaking = None, Click OK
♦
The hyper-terminal folder you just created will open. From the File pull-down menu, select Properties then click on the Setting Tab
♦
In the Properties Settings dialog screen, Select Terminal keys for the Function, arrow and control key; then Select ANSI for Emulation; the Back scroll buffer line can remain at the default 500
Page 4
Page 5
Manual No. 25-ULNFT2100-01; Nov., 2006 ♦
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Click on the ASCII Setup button. In the ASCII Setup Sending screen, select Line ends with line feeds and Echo typed locally so that any keyboard commands you input will appear on your screen. In the ASCII Setup Receiving screen, select Append line feeds to incoming line ends and Wrap lines that exceed terminal width. Click OK. This returns you to the Properties Setting. Click OK
2) Your PC and the scanner should now communicate. To verify that the scanner and the PC are communicating properly, send the following command from your PC keyboard which will request software settings to be displayed. Send the command in four keystrokes: <Esc> Z3 <Enter> Note: Be sure to use capital letters, e.g. “Z3”, not “z3”. A series of software setting should be displayed, indicating that good communications have been established 3) A red LED light should be visible. If it is not visible, the scanner may be in a mode that requires a “Trigger” Command from the PC to activate it. You can exit that mode by sending the following command from your PC keyboard: <Esc> S7 <Enter> 4) The “Trigger” mode will now be deactivated and the red LED light will be continuously illuminated. This Quick Start-Up procedure will get you started. However, to best understand the full capabilities of these scanners, you should read the complete manual.
Page 5
Page 6
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Section 2 Technical Specifications Physical Specifications Case Material Dimensions NFT2100 Dimensions NFT2200 Weight NFT2100 Weight NFT2100 Weight NFT2200 Cable Length Connector Mounting
Steel (Black) 2.17 x 1.85 x 0.78 in (WxDxH) (55 x 47 x 20 mm) 2.17 x 2.05 x 0.78 in (WxDxH) (55 x 52 x 20 mm) 3.5 oz (100 grams) without cable 3.5 oz (100 grams) without cable 3.6 oz (102 grams) without cable 6.5 Feet (2000 mm) 9-pin, DB female connector with power pigtail 4 threaded (M3) mounting holes, 2 on each side
Symbologies Supported ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦
Codabar (NW-7), Codabar ABC, & Codabar CX Code 39 Code 93 Code 128 Industrial 2 of 5 / Interleaved 2 of 5 / Matrix 2 of 5 MSI / Plessey, UK / Plessey WPC (UPC / EAN / JAN) IATA Telepen TriOptic SCode
Optical Specifications Scan Rate Light source Light receiver Focal Distance NFT2100* Focal Distance NFT2200* Field size at focal distance. Narrow Bar Resolution Minimum PCS
200 scans per second ±10% 660 nm, visible red LED CCD Linear image sensor with 2048 pixels 1.4" (35.4 mm) 1.2" (31.4 mm) 3.1" (80 mm) 6 mil (0.15mm) at 0.9 PCS 0.45 (min. background reflectance of 70%)
Reading Distances NFT2100/2200. See Appendix E. * measured from front edge of scanner.
Page 6
Page 7
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Skew 6.3 [0.25]
14.5 [0.57]
20°
20° 103°
10°
Avoid This region
20°
10°
Avoid This region
10°
10°
20° 6.3 [0.25] 103° 14.5 [0.57]
NFT2100
NFT2200
Specified operation at ± 30º or less. (Recommended at + or - 13º) Avoid specular reflection in the dead zone (±10º).
Pitch
6°
6°
0
NFT2100
6°
6°
NFT2200
Specified operation at + 6º or less. (Recommended at 0º)
Page 7
Page 8
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Tilt (Rotation)
10°
10°
10°
10°
NFT2100 NFT2200 Specified operation (θ) ±10º or less. (Barcode aspect ratio must allow the field of view to cover all bars). (Recommended operation at 0º)
Curvature EAN-8 / UPC-E: R = >20 mm (0.8”) or EAN-13 / UPC-A: R => 30 mm (1.2”). Where: PCS = 0.9, Skew=13°, Pitch=0°, Tilt=0°, Label density = 13 mil
35.4 [1.39]
31.4 [1.24]
R
NFT2100
R
NFT2200
Page 8
Page 9
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Electrical Specifications Operating Voltage Current
+5VDC + 5%
Operating (LEDs are ON) Idle (LEDs are OFF) Pwr-On Surge
130mA (max) 45mA (max) 1000mA (max)
RS232 Communications Specifications RS232 Data Transmission Format Default Asynchronous 1 bit 1 bit 8 bit None 9600 baud None
Parameter Timing No. of Start Bits No. of Stop Bits No of Data Bits Parity Baud Rate Handshaking
Optional Settings 1 or 2 bits 7 or 8 bits Odd / Even / None 150 to 38,400 baud Hardware / Software/ None
RS232 Transmit / Receive Character Format Start (First) 1 Bit
Data 7 to 8 Bits LSB
XXXXXX
Stop (Last) 1 to 2 Bits
Parity MSB
1 Bit
RS232 Transmit Data Format, Output from Scanner First to last
Global Prefix
Individual Prefix
Barcode data
Individual Suffix
Global Suffix
Format
0 to 8 characters
0 to 4 characters
1 to 44 characters
0 to 4 characters
0 to 8 characters
Default
0
0
1 to 44
CR
0
RS232 Receive Data Format, Command inputs to scanner. First to last
Prefix for all commands
Commands
Suffix for all Commands
Format
ESC or STX
1 or 2 characters
CR or ETX
ESC
Escape
ASCII 27 (x1B)
CR
Carriage Return
ASCII 13 (x0D)
STX
Start of Text
ASCII
2 (x02)
ETX
End of Text
ASCII
3 (x03)
RS232 Signal Level Signal Name
In / Out
Mark/Off
Space/On
TXD
Out
-5 to -15
+5 to +15
RXD
In
-3 to -15
+3 to +15
Page 9
Page 10
Manual No. 25-ULNFT2100-01; Nov., 2006
NFT2100/2200 CCD Fixed Mount Barcode Scanner
Connector Pin-outs 9 Pin D-Sub Female Connector with power pigtail stereo jack. (3.5mm) Pin No. 1 2 3 4 5 6 7 8 9
Signal Name Trigger TxD RxD NC Signal Ground NC CTS RTS NC Power Pigtail Tip Ring Sleeve
Direction Input Output Input
Signal Level 0 to 0.5V = True ±5 to ±15 Volts ±5 to ±15 Volts
Pwr Return
0 Volts
Input Output
±5 to ±15 Volts ±5 to ±15 Volts
Signal NC +5V Signal Ground
Environmental Specifications Temperature Operating Storage
+32 to +113° F (0° to +45° C) -14 to +140° F (-10° to +60° C)
Humidity (non-condensing) Operating 20 to 80% RH Storage 20 to 90% RH Ambient Light
Fluorescent or incandescent: 5,000 lx max
Anti Static
15KV (non-destructive)
Ordering Information Part No.
Description
NFT2100IR1S-054
Front View, with 9 Pin D-Sub Female Connector with power pigtail. Standard configuration, other configurations are available upon request.
NFT2200LR1S-054
Side View, with 9 Pin D-Sub Female Connector with power pigtail. Standard configuration, other configurations are available upon request.
Regulatory EMC
EN55022, EN55024 FCC
Class B
Page 10