Page 81

OPTICON Universal menu book

3.3.18. Options for Composite Codes CC-A is a modified MicroPDF417 version. CC-B is standard MicroPDF417. CC-C is standard PDF417.

Fig. 3.41. Options for Composite Codes Composite A

Maximum data capacity: • CC-A: 56 characters • CC-B: 338 characters • CC-C: 2361 characters

1D data (1 upto 73 characters)

Symbol size: • 1D part: see RSS and EAN codes • Composite part: CC-A and CC-B same as MicroPDF417, CC-C same as PDF417

Fig. 3.42. Options for Composite Codes composite data (1 upto 56 characters)

Composite B

Error correction: • 1D part: only error detection • Composite part: Reed Solomon error correction

1D data (1 upto 73 characters)

Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • with ECI: many other character sets For string format of composite codes see figure 3.41 or 3.42 or 3.43.

composite data (1 upto 338 characters)

Fig. 3.43. Options for Composite Codes Composite C 1D data (1 upto 73 characters)

Options for Composite codes: • enable composite code • ignore link flag • output mode For string format of composite codes see figure 3.44.

composite data (1 upto 2361 characters)

Fig. Fig.3.44. 3.44.Combined Combinedoptions options for forComposite CompositeCodes Codes Composite Composite Enable Enable BHE BHE BHE BHE BHE BHE BHE BHE BHE BHE BHE BHE BHF BHF BHF BHF BHF BHF BHF BHF BHF BHF BHF BHF

U74

Link Link Flag Flag RP RP RP RP RP RP RQ RQ RQ RQ RQ RQ RP RP RP RP RP RP RQ RQ RQ RQ RQ RQ

Output Output Mode Mode BL0 BL0 BL1 BL1 BL2 BL2 BL0 BL0 BL1 BL1 BL2 BL2 BL0 BL0 BL1 BL1 BL2 BL2 BL0 BL0 BL1 BL1 BL2 BL2

Output Output Result Result 1D 1D/ /1D+2D 1D+2D 2D 2D/ /1D+2D 1D+2D 1D 1D/ /2D 2D/ /1D+2D 1D+2D 1D+2D 1D+2D 1D+2D 1D+2D 1D+2D 1D+2D 1D 1D 2D 2D 1D 1D/ /2D 2D 1D 1D 2D 2D 1D 1D/ /2D 2D

Page 82

OPTICON Universal menu book

3.3.18. Options for Composite Codes

_ZZ_

Not ignore composite link flag

RQ

_RQ_

Ignore composite link flag

RP

_RP_

Disable Composite on GS1-Databar

BHF

_BHF_

Enable Composite on GS1-Databar

BHE

_BHE_

As a single component, only 1D component is allowed

BL0

_BL0_

As a single component, only 2D component is allowed

BL1

_BL1_

As a single component, only 1D+2D component is allowed

BL2

_BL2_

END

_ZZ_

U75

3 Code options

SET

Page 83

OPTICON Universal menu book

3.3.19. Options for Codablock F

3.3.20. Options for DataMatrix

Codablock-F is variable size multi row (stacked) symbology based on Code 128. All features of Code 128 do apply for Codablock F.

Data Matrix is a variable size matrix symbology with selectable error correction levels. Maximum data capacity (ECC200): • alphanumeric data: 2335 characters • 8-bit data: 1556 characters • numeric data: 3116 characters

Maximum data capacity: • text compaction = alphanumeric data: 2684 characters • numeric compaction = numeric data: 5368 characters

Symbol size: ECC000 - 140: • odd number of rows and columns, square shape. • minimum: 9 * 9 modules, maximum: 49 * 49 modules ECC200: • even number of rows and columns, square or rectangular shape • square: minimum 10 * 10, maximum 144 * 144 modules • rectangular: minimum 8 * 18, maximum 16 * 48 modules

Symbol size: • number of rows: 2 up to 44 • number of columns: 1 up to 61 Error detection: Codablock has 1 additional character for the entire symbol. Codablock calculates 1 check digit that is not transmitted. Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • 4 FNC values For string format see figure 3.45.

Error correction: • ECC000 - 140: four levels of convolutional error correction, option for error detection only • ECC200: Reed-Solomon error correction For new applications ECC200 is recommended.

Fig. 3.45. Options for Codablock F Codablock F

Additional features: • extended Channel Interpretation (ECI, ECC200 only): support for different character sets and data interpretations • structured append (ECC200 only): represent data in up to 16 Data Matrix symbols Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent data (1 upto 5368 characters)

Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • with ECI: many other character sets For string format see figure 3.46.

U76

Page 84

OPTICON Universal menu book

3.3.21. Options for Aztec Aztec code is a variable size matrix symbology with selectable error correction levels.

Options for DataMatrix: • Structured append time out: see chapter Read options

Maximum data capacity: Standard Aztec: • alphanumeric: 3067 characters • numeric: 3832 characters • byte: 1914 characters Aztec runes: • values 000 up to 255 ( 3 digits )

Fig. 3.46. Options for DataMatrix DataMatrix data (1 upto 3116 characters)

Error correction: User selectable Reed-Solomon error correction levels from 5% to 95% of data region. Additional features: • extended Channel Interpretation (ECI): support for different character sets and data interpretations • structured append: represent data in up to 26 Aztec symbols • mirror image: decode symbol in mirror reversal presentation Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • with ECI: many other character sets For string format see figure 3.47. Options for Aztec: • structured append time out: see chapter Read options

Fig. 3.47. Options for Aztec Aztec data (1 upto 3832 characters)

U77

3 Code options

Symbol size: Standard Aztec: • minimum: 15 * 15 modules • maximum: 151 * 151 modules Aztec runes: • fixed: 11 * 11 modules

Page 85

OPTICON Universal menu book

3.3.22. Options for Chinese Sensible code Encodable characters: • numerical values 0-9 • ASCII value 0 - 127 ( ISO 646 ) • binary byte • ordinary chinese characters ( GB 18030 - 2 Region, Double-byte, Four-byte ) • with ECI: many other character sets For string format see figure 3.48.

Chinese Sensible code is a matrix symbology with selectable error correction levels. The code allows 84 variable sized versions. Pattern: Each code is a square area comprised of a variable amount of nxn square symbols. A crossing alignment pattern is available in version 4 and its sequential versions. Al versions include four position detection patterns located on each corner.

Fig. 3.48. Options for Chinese Sensible code

Maximum data capacity: The data capacity depends on the version. • version 1: 205 characters • sequential versions: increasing amount per version • version 84: 31091 characters

Chinese Sensible code data (1 upto 31091 characters)

Symbol size: Chinese Sensible code has 84 versions, counting from version 1. Each following version has 2 more modules. • minimum: version 1 = 23 * 23 modules • sequentially: version 2 = 25 * 25, version 3 = 27 * 27, etc. • maximum: version 84 = 189 * 189 modules Error correction: Four levels of Reed-Solomon error correction. Additional feature: Extended Channel Interpretion (ECI): support for chinese character set, other different character sets and data interpretions. Support for this option is reader dependent. The supported character set and the maximum decodable number of characteristics is reader dependent.

U78

Page 86

OPTICON Universal menu book

3.3.23. Options for QR Code Options for QR code: • structured append time out: see read mode options • no further options supported

QR code is a variable size matrix symbology with selectable error correction levels. Maximum data capacity: Model 1: • alphanumeric data: 707 characters • 8-bit data: 486 characters • numeric data: 1167 characters • kanji data: 299 characters Model 2: • alphanumeric data: 4296 characters • 8-bit data: 2953 characters • numeric data: 7089 characters • kanji data: 1817 characters

Fig. 3.49. Options for QR Code QR Code data (1 upto 7089 characters)

3 Code options

Symbol size: Model 1: • minimum: 21 * 21 modules • maximum: 73 * 73 modules Model 2: • minimum: 21 * 21 modules • maximum: 177 * 177 modules Error correction: Four levels of Reed-Solomon error correction. Additional features: • extended Channel Interpretation (ECI, model 2 only): support for different character sets and data interpretations. • structured append: represent data in up to 16 QR Code symbols. Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • with ECI: many other character sets For string format see figure 3.49.

U79

Page 87

OPTICON Universal menu book

3.3.24. Options for Micro QR Code

3.3.25. Options for Maxicode

Micro QR code is a compact version for the regular QR Code.

Maxicode is a fixed size matrix symbology with selectable error correction levels.

Maximum data capacity: Model 1: • numeric data: 5 characters Model 2: • alphanumeric data: 6 characters • numeric data: 10 characters Model 3: • alphanumeric data: 11 characters • 8-bit data: 9 characters • numeric data: 18 characters • kanji data: 6 characters Model 4: • alphanumeric data: 21 characters • 8-bit data: 15 characters • numeric data: 35 characters • kanji data: 9 characters

Maximum data capacity: • alphanumeric data: 93 characters • numeric data: 138 characters Symbol size: 28.14mm wide * 26.91mm high ( including quiet zones ) Error correction: 2 levels of Reed-Solomon error correction. Additional features: • extended Channel Interpretation (ECI): support for different character sets and data interpretations • structured append: represent data in up to 8 Maxicode symbols Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent.

Symbol size: Model 1: • 11 modules Model 2: • 13 modules Model 3: • 15 modules Model 4: • 17 modules

Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • with ECI: many other character sets For string format see figure 3.51.

Error correction: Up to three levels of Reed-Solomon error correction for Model 4, no error correction for Model 1.

Options for Maxicode: • structured append time out: see read mode options • no further options supported

Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) For string format see figure 3.50.

Fig. 3.51. Options for Maxicode

Options Micro QR Code • no options supported

Maxicode data (1 upto 138 characters)

Fig. 3.50. Options for Micro QR Code Micro QR Code data (1 upto 35 characters)

U80

Page 88

OPTICON Universal menu book

3.3.27. Options for MicroPDF417

PDF417 is variable size multi row (stacked) symbology with selectable error correction levels.

MicroPDF417 is variable size multi row (stacked) symbology with fixed error correction levels.

Maximum data capacity: • text compaction: 1850 characters • byte compaction: 1108 characters • numeric compaction: 2710 characters

Maximum data capacity: • text compaction: 250 characters • byte compaction: 150 characters • numeric compaction:366 characters

Symbol size: • number of row: 3 up to 90 • number of columns: 1 up to 30

Symbol size: • number of row: 4 up to 44 • number of columns: 1 up to 4

Error correction: 8 levels of error correction. Option for error detection only.

Error correction: Number of error correction codewords is dependent of symbol size and can not be changed.

Additional features: • extended Channel Interpretation (ECI): support for different character sets and data interpretations • macro PDF417: represent data in up to 99.999 PDF417 symbols • truncated PDF417: reduce some overhead to obtain smaller symbology size Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent

Additional features: • extended Channel Interpretation (ECI): support for different character sets and data interpretations • macro MicroPDF417 ( structured append mode ): represent data in up to 99.999 MicroPDF417 symbols Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent

Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • for macro PDF417: many other character sets For string format see figure 3.52

Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • for macro MicroPDF417: many other character sets For string format see figure 3.53.

Options for PDF417: • macro PDF417 timeout ( same as Structured append time out ): see read mode options • no further options available

Options for MicroPDF417: • macro MicroPDF417 timeout ( same as Structured append time out ): see read mode options • no further options available

Fig. 3.52. Options for PDF417

Fig. 3.53. Options for MicroPDF417

PDF417

MicroPDF417 data (1 upto 2710 characters)

data (1 upto 366 characters)

U81

3 Code options

3.3.26. Options for PDF417

Page 89

OPTICON Universal menu book

U82

Page 90

OPTICON Universal menu book

4. STRING OPTIONS This chapter describes the alterations which can be made to the format of the transmitted data string. Options available are: Case conversion • conversion of bar code data The bar code data has the format as described in chapter ‘Code Options’.

4 String options

Set prefix and suffix • transmission of a preamble (common prefix) • transmission of a postamble (common suffix) • transmission of a prefix • transmission of a suffix The string format is transmitted as in figure 4.01.

Fig. 4.01. String Options preamble prefix bar code data suffix including Code ID including Code ID including Code length including Code length postamble

The input entries are described in this chapter.

U83