Page 71

OPTICON Universal menu book

3.3.9. Options for Telepen Telepen is a variable length symbology with a check digit and non printable start/stop characters. The following characters are supported: • in numeric mode, the digits 00 upto 99 • in full ASCII mode, all 128 ASCII characters

Fig. 3.30. Options for Telepen Telepen data (1 upto 32 characters)

The check digit calculation is derived from the sum of all data characters modulo 127. The check digit cannot be transmitted. For string format see figure 3.30. Options for Telepen: • selection of ASCII mode

SET

_ZZ_

Numeric mode

D2

_D2_

ASCII mode

D3

_D3_

END

_ZZ_

U64 check digit

Page 72

OPTICON Universal menu book

3.3.10. Options for UK/Plessey Space insertion: This option inserts spaces in position 2, 5, 11, 14 of the data string for use in library systems.

UK Plessey is a variable length symbology with a mandatory checksum and non printable start/ stop characters. The following characters are supported: • the digits 0 upto 9 • the characters A upto F

A to X conversion: This option converts the character 'A' into an 'X'. The data and check digits are affected.

The checksum contains 2 digits and is calculated from the numerical values of all the data digits. For string format see figure 3.31.

Fig. 3.31. Options for UK/Plessey UK/Plessey data (5 upto 20 characters)

SET

_ZZ_

Not transmit CD's

4O

_4O_

Transmit CD's

4N

_4N_

Disable space insertion

DO

_DO_

Enable space insertion

DN

_DN_

Disable A to X conversion

DP

_DP_

Enable A to X conversion

DQ

_DQ_

END

_ZZ_

U65 check digits

3 Code options

Options for UK Plessey: • enable A to X conversion • disable transmission of the check digits • enable library space (CLSI) insertion

Page 73

OPTICON Universal menu book

3.3.11. Options for Code 128 and GS1-128 Code 128: Code 128 is a variable length symbology with a mandatory check digit and non printable start/ stop characters. The following characters are supported: • all 128 ASCII characters • 4 non data function characters • 3 start characters • 4 code set selection characters • 1 stop character

FNC2 Concatenation: If a Code 128 bar code contains a leading FNC2 character, the data is stored into the reader's buffer. As soon as a Code 128 bar code is read without a leading FNC2 character, the data is appended to the reader's buffer and the entire buffer is transmitted and cleared for new data. In case a non Code 128 bar code is read, the data in the non-Code 128 bar code is transmitted and the buffer is cleared. The buffer size is reader dependent.

The check digit is calculated as the sum modulo 103 of the start character and the weighted values of the data and special characters. For string format see figure 3.32.

Fig. 3.32. Options for Code 128 and GS1-128 Options for Code 128: • enable concatenation

Code 128 data (1 or more characters)

GS1-128: In this mode the Code128 data is translated to the GS1-128 format, formerly known as EAN128 or UCC-128. GS1-128 data starts with the FNC1 character and separates 2 data fields with the FNC1 character. The first FNC1 character is translated to ]C1, and the second FNC1 character is translated to an ASCII GS (hex 1D) character. For string format see figure 3.33.

Fig. 3.33. Options for Code 128 and GS1-128 GS1-128 ]C1

Options for GS1-128: • enable GS1-128 conversion Enable GS1-128 only: In this mode the decoded data characters are translated to the GS1-128 format. If the data does not comply with the GS1-128 format, then the label is rejected. Enable GS1-128 if possible: In this mode the decoded data characters are translated to the GS1-128 format. If the data does not comply with the GS1-128 format, then the label is transmitted as Code 128.

U66 data (1 or more char.)

<GS> data (1 or more char.)

Page 74

OPTICON Universal menu book

3.3.11. Options for Code 128 and GS1-128

_ZZ_

Disable GS1-128

OF

_OF_

Enable GS1-128 only

JF

_JF_

Enable GS1-128 if possible

OG

_OG_

Disable concatenation

MP

_MP_

Enable concatenation

MO

_MO_

END

_ZZ_

U67

3 Code options

SET

Page 75

OPTICON Universal menu book

3.3.12. Options for Code 93 Code 93 is a variable length symbology with 2 mandatory check digits and non printable start/ stop characters. The following characters are supported: • the digits 0 upto 9 • the upper case characters A upto Z • the characters - . $ / + % SPACE • 4 non printable shift characters

Fig. 3.34. Options for Code 93 Code 93 data (1 or more characters)

The first check digit (C) is the modulo 47 sum of the weighted data character values. The second check digit (K) is the modulo 47 sum of the weighted data character values including the first check digit (C). The check digits are not transmitted. The special shift characters are control characters and are not transmitted with the data. If one of these characters is followed by an upper case character 'A' upto 'Z', it is transmitted as 1 single character. In case of an invalid combination, the label is rejected. This method enables support for full 128 ASCII characters encodation. The encodation is compatible with the Code 39 $, %, / and + characters. For string format see figure 3.34. Options for Code 93: • enable concatenation • transmission of check digits • calculation of check digits Concatenation: If a Code 93 bar code contains a leading space, the data is stored into the reader's buffer without the leading space. As soon as a Code 93 bar code is read without a leading space, the data is appended to the reader's buffer and the entire buffer is transmitted and cleared for new data. In case a non Code 93 bar code is read, the data in the non-Code 93 bar code is transmitted and the buffer is cleared. The buffer size is reader dependent. Support for this option is reader dependent.

U68 check digit C check digit K

Page 76

OPTICON Universal menu book

3.3.12. Options for Code 93

_ZZ_

Not check CD

9Q

_9Q_

Check CD

AC

_AC_

Not transmit CD

DZ

_DZ_

Transmit CD

DY

_DY_

Disable concatenation

+W

_+W_

Enable concatenation

+V

_+V_

END

_ZZ_

U69

3 Code options

SET

Page 77

OPTICON Universal menu book

3.3.13. Options for Code 11 Code 11 is a variable length symbology with 1 or 2 optional check digits and non printable start/stop characters. If the data is 10 or less characters, one check digit is used. If the data is more then 10 characters, then 2 check digits are used. The following characters are supported: • the digits 0 upto 9 • the dash character '-'

Options for Code 11: • disable check digit(s) • automatic checking for 1 or 2 check digits depending of the number of data characters • enable transmission of check digit(s)

The first check digit is the modulo 11 sum of the weighted data character values. The second check digit is the modulo 11 sum of the weighted data character values including the first check digit. The check digits are not transmitted. For string format see figure 3.35.

Code 11

Fig. 3.35. Options for Code 11 data (1 or more characters)

SET

_ZZ_

Not check CD

BLF

_BLF_

Check 1 CD

BLG

_BLG_

Check 2 CDs

BLH

_BLH_

Check auto 1 or 2 CDs

BLI

_BLI_

Not transmit CD(s)

BLJ

_BLJ_

Transmit CD(s)

BLK

_BLK_

END

_ZZ_

U70 cd1 cd2

Page 78

OPTICON Universal menu book

3.3.14. Options for Korean Postal Authority code Transmit dash: The dash character '-' ( hex 2D ) is printed between the 3rd and 4th digit

Korean Postal Authority code is a fixed length numeric symbology with a mandatory check digit. The check digit is not transmitted. For string format see figure 3.36. Options for Korean Postal Authority code: • transmit dash • not transmit dash • transmit CD • not transmit CD

Fig. 3.36. Options for Korean Postal Authority code Korean Postal Authority code check digit

SET

_ZZ_

Not transmit CD

*-

_*-_

Transmit CD

*+

_*+_

Not transmit dash

*/

_*/_

Transmit dash

*.

_*._

END

_ZZ_

U71 dash (-)

data (3 digits)

3 Code options data (3 digits)

Page 79

OPTICON Universal menu book

3.3.15. Options for Intelligent Mail Barcode

3.3.16. Options for POSTNET

Intelligent Mail Barcode is a symbology in four different states. It is formerly known as OneCode and is a variant of the 4-State Customer Barcode. The symbology is a height modulated and has a number of fixed lengths. For string format see figure 3.37.

POSTNET (Postal Numeric Encoding Technique) is a height modulated symbology with a number of fixed lengths. For string format see figure 3.38. Fixed data capacity: • Numeric data: 5 / 6 / 9 / 11 characters • Additional data: 1 check digit

Fixed data capacity: • Numeric data: 20, 25 , 29 or 31 characters

Checkdigit: The start and stop pattern consist of a fixed single frame bar which is not unique inside the code. It is not transmitted. The checkdigit is calculated and transmitted with the barcode data.

Fixed data format and size: The data is built of several identifiers which follow each other in fixed order. Sizes are a predetermined amount of digits. • Barcode identifier: 2 • Service type identifier: 3 • Mailer ID and Sequence number: maybe 6+9 digits or 9+6, always totalized to 15 • Delivery point zip code: may be omitted (0), standard zip (5), zip+4 (9), zip+4 incl. delivery point digits (11)

Encodable characters: • digits 0 up to 9

Fig. 3.38. Options for POSTNET

Checksum: An 11-bit CRC Frame Check Sequence is always calculated and is not transmitted.

POSTNET data 5, 6, 9 or 11 digits

Encodable characters: • digits 0 up to 9

Fig. 3.37. Options for Intelligent Mail Barcode Intelligent Mail Barcode barcode identifier service type identifier

2 digits

3 digits mailer + sequence ID number 6 + 9 digits or 9 + 6 digits delivery point zip code 0, 5, 9 or 11 digits

U72 check digit

Page 80

OPTICON Universal menu book

The next GS1 Databar versions are supported. • Omnidirectional/Truncated/Stacked (refer to GS1 Databar) • Limited (refer to GS1 Databar Limited) • Expanded, Expanded stacked (refer to GS1 Databar Expanded) For string format see figure 3.39 or 3.40.

3.3.17. Options for GS1 Databar GS1 Databar is formerly known as RSS familiy including the RSS-14 group. Support for GS1 Databar options is reader dependent. Maximum data capacity: • GS1 Databar and GS1 Databar Limited: Application Identifier "01" and 14 digits. • GS1 Databar Expanded: 74 numeric or 41 alpha characters

Options for GS1 Databar: • transmission of CD • transmission of Application Identifier

Fig. 3.39. Options for GS1 Databar GS1 Databar, GS1 Databar Limited application identifier (01)

Encodable characters: • GS1 Databar and GS1 Databar Limited: digits 0 up to 9 • GS1 Databar Expanded: subset of ISO 646: upper, lower case characters, digits, 20 punctuation characters and function character FNC1 data (13 digits)

cd (1 digit)

Fig. 3.40. Options for GS1 Databar GS1 Databar Expanded data (1 upto 73 characters)

SET

_ZZ_

Not transmit CD

DM

_DM_

Transmit CD

DL

_DL_

Not transmit Application Identifier

DT

_DT_

Transmit Application Identifier

DS

_DS_

END

_ZZ_ U73 cd (1 character)

3 Code options

Not transmit CD: Do not transmit the last character of GS1 Databar.

Checksums: The GS1 Databar family uses a mandatory checksum. •GS1 Databar uses a modulo 79 checksum, •GS1 Databar Limited uses a modulo 89 checksum •GS1 Databar Expanded uses a modulo 211 checksum. The checksum is always calculated and is not transmitted.